Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

被引:233
|
作者
Leipsic, Jonathon [1 ,2 ,7 ]
LaBounty, Troy M. [3 ]
Heilbron, Brett [2 ,7 ]
Min, James K. [3 ,4 ]
Mancini, G. B. John [5 ]
Lin, Fay Y. [3 ]
Taylor, Carolyn [2 ,7 ]
Dunning, Allison [3 ]
Earls, James P. [6 ]
机构
[1] St Pauls Hosp, Dept Med Imaging, Vancouver, BC V6Y 126, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[4] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[6] Fairfax Radiol Consultants, Fairfax, VA USA
[7] Univ British Columbia, Dept Radiol, Div Cardiol, Vancouver, BC, Canada
关键词
adaptive statistical iterative reconstruction; coronary CT angiography; iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; HELICAL CT; RADIOLOGY; ALGORITHM; COMMITTEE; EXPOSURE; HEART;
D O I
10.2214/AJR.10.4288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and study quality for coronary CT angiography (CTA). SUBJECTS AND METHODS. We prospectively evaluated 574 consecutive patients undergoing coronary CTA at three centers. Comparisons were performed between consecutive groups initially using filtered back projection (FBP) (n = 331) and subsequently ASIR (n = 243) with regard to patient and scan characteristics, radiation dose, and diagnostic study quality. RESULTS. There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction in radiation dose compared with FBP (95% CI, 21-32%; p < 0.001). Despite the reduced current, ASIR was not associated with a difference in adjusted signal, noise, or signal-to-noise ratio (p = not significant). No differences existed between FBP and ASIR for interpretability per coronary artery (98.5% vs 99.3%, respectively; p = 0.12) or per patient (96.1% vs 97.1%, p = 0.65). CONCLUSION. ASIR enabled reduced tube current and lower radiation dose in comparison with FBP, with preserved signal, noise, and study interpretability, in a large multicenter cohort. ASIR represents a new technique to reduce radiation dose in coronary CTA studies.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [21] Image quality in coronary computed tomography angiography: influence of adaptive statistical iterative reconstruction at various radiation dose levels
    Precht, Helle
    Gerke, Oke
    Thygesen, Jesper
    Egstrup, Kenneth
    Auscher, Soren
    Waaler, Dag
    Lambrechtsen, Jess
    ACTA RADIOLOGICA, 2018, 59 (10) : 1194 - 1202
  • [22] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07) : 1775 - 1786
  • [23] New scanning technique using Adaptive Statistical Iterative Reconstruction (ASIR) significantly reduced the radiation dose of cardiac CT
    Tumur, Odgerel
    Soon, Kean
    Brown, Fraser
    Mykytowycz, Marcus
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 292 - 296
  • [24] Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies
    Peter Komlosi
    Yanrong Zhang
    Carlos Leiva-Salinas
    David Ornan
    James T. Patrie
    Wenjun Xin
    Deborah Grady
    Max Wintermark
    Neuroradiology, 2014, 56 : 187 - 193
  • [25] Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography
    Shen, Junlin
    Du, Xiangying
    Guo, Daode
    Cao, Lizhen
    Gao, Yan
    Bai, Mei
    Li, Pengyu
    Liu, Jiabin
    Li, Kuncheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 349 - 355
  • [26] Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study
    Gregory A. Vorona
    Rafael C. Ceschin
    Barbara L. Clayton
    Tom Sutcavage
    Sameh S. Tadros
    Ashok Panigrahy
    Pediatric Radiology, 2011, 41 : 1174 - 1182
  • [27] Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study
    Vorona, Gregory A.
    Ceschin, Rafael C.
    Clayton, Barbara L.
    Sutcavage, Tom
    Tadros, Sameh S.
    Panigrahy, Ashok
    PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1174 - 1182
  • [28] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [29] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [30] Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique
    Prakash, Priyanka
    Kalra, Mannudeep K.
    Kambadakone, Avinash K.
    Pien, Homer
    Hsieh, Jiang
    Blake, Michael A.
    Sahani, Dushyant V.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (04) : 202 - 210