共 55 条
A chemometric experimental design with three-step stacking capillary electrophoresis for analysis of five tobacco-specific nitrosamines in cigarette products
被引:6
作者:
Cheng, Cheng-Wei
[1
]
Kou, Hwang-Shang
[1
]
Wu, Shou-Mei
[2
,3
,7
]
Wang, Chun-Chi
[1
,4
,5
,6
]
机构:
[1] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Pharm, Dept Fragrance & Cosmet Sci, Kaohsiung, Taiwan
[3] Minist Hlth & Welf, Taiwan Food & Drug Adm, Taipei, Taiwan
[4] Kaohsiung Med Univ Hosp, Dept Med Res, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ Hosp, Drug Dev & Value Creat Res Ctr, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Sch Pharm, Coll Pharm, 100 Shi Chuan 1st Rd, Kaohsiung 807, Taiwan
[7] Kaohsiung Med Univ, Dept Fragrance & Cosmet Sci, Coll Pharm, 100 Shi Chuan 1st Rd, Kaohsiung 807, Taiwan
关键词:
FASI-sweeping-AFMC;
Carcinogens;
Tobacco -specific nitrosamines;
Chemometric experimental design;
ONLINE SAMPLE CONCENTRATION;
SOLID-PHASE EXTRACTION;
N-NITROSAMINES;
SOLVENT STACKING;
MASS SPECTROMETRY;
MICELLE COLLAPSE;
LIQUID;
CHROMATOGRAPHY;
INJECTION;
ALKALOIDS;
D O I:
10.1016/j.chroma.2022.463283
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Tobacco-specific nitrosamines (TSNAs) as carcinogens endanger our health and life from cigarette products. However, the safe range of TSNAs levels in commercial cigarette products has not yet been established. For the purpose of safety and supervision, a three-step stacking approach including field amplified sample injection (FASI), sweeping, and analyte focusing by micelle collapse (AFMC), was developed for the simultaneous determination of five TSNAs levels in cigarette products. This approach also involved aspects of chemometric experimental design, including fractional factorial design and central composite design. After the multilevel optimization of the experimental design, the five TSNAs were well separated. The LOD (S/ N = 3) values of the N '-nitrosonornicotine (NNN), N '-nitrosoanatabine (NAT), N '-nitrosoanabasine (NAB), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), and 4-(methylnitrosamino)-1-(3-pyridyl)1-butanone (NNK) in the FASI-sweeping-AFMC CE approach were 1.0 0 0 ng/mL, 0.50 0 ng/mL, 0.125 ng/mL, 1.0 0 0 ng/mL, and 0.500 ng/mL respectively. The results of relative standard deviation (RSD) and relative error (RE) were all less than 3.35%, demonstrating good precision and accuracy. Finally, this novel approach was further applied to monitor three commercial cigarette products, and a range of 250.1- 336.6 ng/g for NNN, 481.6-526.7 ng/g for NAT, 82.2-247.6 ng/g for NAB, 167.7-473.7 ng/g for NNAL, and 39.4-246.7 ng/g for NNK could be observed among these. Based on these results, the novel CE stacking strategy was successfully applied for the analysis of five TSNAs levels in cigarette products and could serve as a tool for assays of quality control of nitrosamines.
引用
收藏
页数:13
相关论文