ROC study and SUV threshold using quantitative multi-modal SPECT for bone imaging

被引:19
|
作者
Vija, A. H. [1 ]
Bartenstein, P. A. [4 ]
Froelich, J. W. [3 ]
Kuwert, T. [2 ]
Macapinlac, H. [5 ]
Daignault, C. P. [3 ,8 ]
Gowda, N. [3 ,9 ]
Hadjiev, O. [3 ,10 ]
Hephzibah, J. [6 ,7 ]
Huang, P. [6 ]
Ilhan, H. [4 ]
Jessop, A. [5 ,11 ]
Cachovan, M. [12 ]
Ma, J. [1 ]
Ding, X. [1 ]
Spence, D. [1 ]
Platsch, G. [12 ]
Szabo, Z. [6 ]
机构
[1] Siemens Med Solut USA Inc, Mol Imaging, Hoffman Estates, IL 60192 USA
[2] Friedrich Alexander Univ Erlangen, Erlangen, Germany
[3] Univ Minnesota, Minneapolis, MN USA
[4] Ludwig Maximilians Univ Munchen, Munich, Germany
[5] MD Anderson Canc Ctr, Houston, TX USA
[6] Johns Hopkins Univ, Baltimore, MD USA
[7] Christian Med Coll & Hosp, Vellore, Tamil Nadu, India
[8] Vet Med Ctr, Minneapolis, MN USA
[9] Consulting Radiol, Edina, MN USA
[10] Milwaukee Radiologists, Greenfield, WI USA
[11] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[12] Siemens Healthineers GmbH, Erlangen, Germany
来源
EUROPEAN JOURNAL OF HYBRID IMAGING | 2019年 / 3卷 / 01期
关键词
SPECT; CT; Quantitative SPECT; xSPECT quant; xSPECT bone; Bone imaging; Concordance; ROC; AUC; SUV; Tc99m; MDP; DPD; Diphosphonate;
D O I
10.1186/s41824-019-0057-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe investigated the clinical performance of a quantitative multi-modal SPECT/CT reconstruction platform for yielding radioactivity concentrations of bone imaging with Tc-99m-methylene diphosphonate (MDP) or Tc-99m-dicarboxypropane diphosphonate (DPD). The novel reconstruction incorporates CT-derived tissue information while preserving the delineation of tissue boundaries. We assessed image-based reader concordance and confidence, and determined lesion classification and SUV thresholds from ROC analysis.MethodsSeventy-two cancer patients were scanned at three US and two German clinical sites, each contributing two experienced board-certified nuclear medicine physicians as readers. We compared four variants of the reconstructed data resulting from the Flash3D (F3D) and the xSPECT Bone (TM) (xB) iterative reconstruction methods and presented images to the readers with and without a fused CT, resulting in four combinations. We used an all-or-none approach for inclusion, compiling results only when a reader completed all reads in a subset. After the final read, we conducted a "surrogate truth" reading, presenting all data to each reader. For any remaining discordant lesions, we conducted a consensus read. We next undertook ROC analysis to determine SUV thresholds for differentiating benign and lesional uptake.ResultsOn a five-point rating scale of image quality, xB was deemed better by almost two points in resolution and one point better in overall acceptance compared to F3D. The absolute agreement of the rendered decision between the nine readers was significantly higher with CT information either inside the reconstruction (xB, xBCT) or simply through image fusion (F3DCT): 0.70 (xBCT), 0.67 (F3DCT), 0.64 (xB), and 0.46 (F3D). The confidence level to characterize the lesion was significantly higher (3.03x w/o CT, 1.32x w/CT) for xB than for F3D. There was high correlation between xB and F3D scores for lesion detection and classification, but lesion detection confidence was 41% higher w/o CT, and 21% higher w/CT for xB compared to F3D. Without CT, xB had 6.6% higher sensitivity, 7.1% higher specificity, and 6.9% greater AUC compared to F3D, and similarly with CT-fusion. The overall SUV-criterion (SUVc) of xB (12) exceeded that for xSPECT Quant (TM) (xQ; 9), an approach not using the tissue delineation of xB. SUV critical numbers depended on lesion volume and location. For non-joint lesions >6 ml, the AUC for xQ and xB was 94%, with SUVc>9.28 (xQ) or >9.68 (xB); for non-joint lesions <= 6 ml, AUCs were 81% (xQ) and 88% (xB), and SUVc>8.2 (xQ) or >9.1 (xB). For joint lesions, the AUC was 80% (xQ) and 83% (xB), with SUVc>8.61 (xQ) or >13.4 (xB).ConclusionThe incorporation of high-resolution CT-based tissue delineation in SPECT reconstruction (xSPECT Bone) provides better resolution and detects smaller lesions (6 ml), and the CT component facilitates lesion characterization. Our approach increases confidence, concordance, and accuracy for readers with a wide range of experience. The xB method retained high reading accuracy, despite the unfamiliar image presentation, having greatest impact for smaller lesions, and better localization of foci relative to bone anatomy. The quantitative assessment yielded an SUV-threshold for sensitively distinguishing benign and malignant lesions. Ongoing efforts shall establish clinically usable protocols and SUV thresholds for decision-making based on quantitative SPECT.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Evaluation of bone metastasis burden as an imaging biomarker by quantitative single-photon emission computed tomography/computed tomography for assessing prostate cancer with bone metastasis: a phantom and clinical study
    Motegi, Kazuki
    Matsutomo, Norikazu
    Yamamoto, Tomoaki
    Koizumi, Mitsuru
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (03) : 219 - 229
  • [42] PET/SPECT/spectral-CT/CBCT imaging in a small-animal radiation therapy platform: A Monte Carlo study-Part I: Quad-modal imaging
    Wang, Hui
    Li, Xiadong
    Xu, Lixia
    Kuang, Yu
    MEDICAL PHYSICS, 2024, 51 (04) : 2941 - 2954
  • [43] Auto-segmentation of pancreatic tumor in multi-modal image using transferred DSMask R-CNN network
    Yao, Yao
    Chen, Yang
    Gou, Shuiping
    Chen, Shuzhe
    Zhang, Xiangrong
    Tong, Nuo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 83
  • [44] Multi-Modal Medical Image Fusion With Adaptive Weighted Combination of NSST Bands Using Chaotic Grey Wolf Optimization
    Asha, C. S.
    Lal, Shyam
    Gurupur, Varadraj Prabhu
    Saxena, P. U. Prakash
    IEEE ACCESS, 2019, 7 : 40782 - 40796
  • [45] Extracardiac activity complicates quantitative cardiac SPECT imaging using a simultaneous transmission-emission approach
    Heller, EN
    DeMan, P
    Liu, YH
    Dione, DP
    Zubal, IG
    Wackers, FJT
    Sinusas, AJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (12) : 1882 - 1890
  • [46] Bayesian multi-modal model comparison: A case study on the generators of the spike and the wave in generalized spike-wave complexes
    Daunizeau, Jean
    Vaudano, Anna E.
    Lemieux, Louis
    NEUROIMAGE, 2010, 49 (01) : 656 - 667
  • [47] Comparison of the detectability of hot lesions on bone SPECT using six state-of-the-art SPECT/CT systems: a multicenter phantom study to optimize reconstruction parameters
    Ichikawa, Hajime
    Shibutani, Takayuki
    Matsutake, Yuki
    Kato, Toyohiro
    Ikematsu, Ryuji
    Higashi, Riwa
    Kamiya, Takashi
    Shimada, Hideki
    Onoguchi, Masahisa
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 839 - 849
  • [48] Quantitative SPECT/CT imaging of lead-212: a phantom study (vol 9, 52, 2022)
    Kvassheim, Monika
    Revheim, Mona-Elisabeth R.
    Stokke, Caroline
    EJNMMI PHYSICS, 2022, 9 (01)
  • [49] A retrospective study of SPECT/CT scans using SUV measurement of the normal pelvis with Tc-99m methylene diphosphonate
    Wang, Ruifeng
    Duan, Xiaoyi
    Shen, Cong
    Han, Dong
    Ma, Junchao
    Wu, Hulin
    Xu, Xiaotong
    Qin, Tao
    Fan, Qiuju
    Zhang, Zhaoguo
    Shi, Weihua
    Guo, Youmin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (06) : 895 - 908
  • [50] Optimization of Number of Iterations as a Reconstruction Parameter in Bone SPECT Imaging Using a Novel Thoracic Spine Phantom
    Fukami, Mitsuha
    Matsutomo, Norikazu
    Yamamoto, Tomoaki
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2021, 49 (02) : 143 - 149