ROC study and SUV threshold using quantitative multi-modal SPECT for bone imaging

被引:19
|
作者
Vija, A. H. [1 ]
Bartenstein, P. A. [4 ]
Froelich, J. W. [3 ]
Kuwert, T. [2 ]
Macapinlac, H. [5 ]
Daignault, C. P. [3 ,8 ]
Gowda, N. [3 ,9 ]
Hadjiev, O. [3 ,10 ]
Hephzibah, J. [6 ,7 ]
Huang, P. [6 ]
Ilhan, H. [4 ]
Jessop, A. [5 ,11 ]
Cachovan, M. [12 ]
Ma, J. [1 ]
Ding, X. [1 ]
Spence, D. [1 ]
Platsch, G. [12 ]
Szabo, Z. [6 ]
机构
[1] Siemens Med Solut USA Inc, Mol Imaging, Hoffman Estates, IL 60192 USA
[2] Friedrich Alexander Univ Erlangen, Erlangen, Germany
[3] Univ Minnesota, Minneapolis, MN USA
[4] Ludwig Maximilians Univ Munchen, Munich, Germany
[5] MD Anderson Canc Ctr, Houston, TX USA
[6] Johns Hopkins Univ, Baltimore, MD USA
[7] Christian Med Coll & Hosp, Vellore, Tamil Nadu, India
[8] Vet Med Ctr, Minneapolis, MN USA
[9] Consulting Radiol, Edina, MN USA
[10] Milwaukee Radiologists, Greenfield, WI USA
[11] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[12] Siemens Healthineers GmbH, Erlangen, Germany
来源
EUROPEAN JOURNAL OF HYBRID IMAGING | 2019年 / 3卷 / 01期
关键词
SPECT; CT; Quantitative SPECT; xSPECT quant; xSPECT bone; Bone imaging; Concordance; ROC; AUC; SUV; Tc99m; MDP; DPD; Diphosphonate;
D O I
10.1186/s41824-019-0057-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe investigated the clinical performance of a quantitative multi-modal SPECT/CT reconstruction platform for yielding radioactivity concentrations of bone imaging with Tc-99m-methylene diphosphonate (MDP) or Tc-99m-dicarboxypropane diphosphonate (DPD). The novel reconstruction incorporates CT-derived tissue information while preserving the delineation of tissue boundaries. We assessed image-based reader concordance and confidence, and determined lesion classification and SUV thresholds from ROC analysis.MethodsSeventy-two cancer patients were scanned at three US and two German clinical sites, each contributing two experienced board-certified nuclear medicine physicians as readers. We compared four variants of the reconstructed data resulting from the Flash3D (F3D) and the xSPECT Bone (TM) (xB) iterative reconstruction methods and presented images to the readers with and without a fused CT, resulting in four combinations. We used an all-or-none approach for inclusion, compiling results only when a reader completed all reads in a subset. After the final read, we conducted a "surrogate truth" reading, presenting all data to each reader. For any remaining discordant lesions, we conducted a consensus read. We next undertook ROC analysis to determine SUV thresholds for differentiating benign and lesional uptake.ResultsOn a five-point rating scale of image quality, xB was deemed better by almost two points in resolution and one point better in overall acceptance compared to F3D. The absolute agreement of the rendered decision between the nine readers was significantly higher with CT information either inside the reconstruction (xB, xBCT) or simply through image fusion (F3DCT): 0.70 (xBCT), 0.67 (F3DCT), 0.64 (xB), and 0.46 (F3D). The confidence level to characterize the lesion was significantly higher (3.03x w/o CT, 1.32x w/CT) for xB than for F3D. There was high correlation between xB and F3D scores for lesion detection and classification, but lesion detection confidence was 41% higher w/o CT, and 21% higher w/CT for xB compared to F3D. Without CT, xB had 6.6% higher sensitivity, 7.1% higher specificity, and 6.9% greater AUC compared to F3D, and similarly with CT-fusion. The overall SUV-criterion (SUVc) of xB (12) exceeded that for xSPECT Quant (TM) (xQ; 9), an approach not using the tissue delineation of xB. SUV critical numbers depended on lesion volume and location. For non-joint lesions >6 ml, the AUC for xQ and xB was 94%, with SUVc>9.28 (xQ) or >9.68 (xB); for non-joint lesions <= 6 ml, AUCs were 81% (xQ) and 88% (xB), and SUVc>8.2 (xQ) or >9.1 (xB). For joint lesions, the AUC was 80% (xQ) and 83% (xB), with SUVc>8.61 (xQ) or >13.4 (xB).ConclusionThe incorporation of high-resolution CT-based tissue delineation in SPECT reconstruction (xSPECT Bone) provides better resolution and detects smaller lesions (6 ml), and the CT component facilitates lesion characterization. Our approach increases confidence, concordance, and accuracy for readers with a wide range of experience. The xB method retained high reading accuracy, despite the unfamiliar image presentation, having greatest impact for smaller lesions, and better localization of foci relative to bone anatomy. The quantitative assessment yielded an SUV-threshold for sensitively distinguishing benign and malignant lesions. Ongoing efforts shall establish clinically usable protocols and SUV thresholds for decision-making based on quantitative SPECT.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Standardized uptake values of 99mTc-MDP in normal vertebrae assessed using quantitative SPECT/CT for differentiation diagnosis of benign and malignant bone lesions
    Qi, Na
    Meng, Qingyuan
    You, Zhiwen
    Chen, Huiqian
    Shou, Yi
    Zhao, Jun
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [32] Nasopharyngeal carcinoma segmentation based on enhanced convolutional neural networks using multi-modal metric learning
    Ma, Zongqing
    Zhou, Shuang
    Wu, Xi
    Zhang, Heye
    Yan, Weijie
    Sun, Shanhui
    Zhou, Jiliu
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02)
  • [33] Assessment of gastric accommodation using quantitative SPECT imaging and high-resolution manometry in a healthy multi-ethnic Asian population
    Tagiling, Nashrulhaq
    Nawi, Norazlina Mat
    Lee, Yeong Yeh
    Rohani, Mohd Fazrin Mohd
    Tan, Phei Oon
    Zulkifli, Khairil Khuzaini
    Zainon, Wan Mohd Nazlee Wan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 : 152 - 152
  • [34] PEPI Lab: a flexible compact multi-modal setup for X-ray phase-contrast and spectral imaging
    Brombal, Luca
    Arfelli, Fulvia
    Menk, Ralf Hendrik
    Rigon, Luigi
    Brun, Francesco
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] A Quantitative Study on Acupuncture Effects for Fighting Migraine Using SPECT Images
    Lopez, M.
    Ramirez, J.
    Gorriz, J. M.
    Chaves, R.
    Gomez-Rio, M.
    NEW CHALLENGES ON BIOINSPIRED APPLICATIONS: 4TH INTERNATIONAL WORK-CONFERENCE ON THE INTERPLAY BETWEEN NATURAL AND ARTIFICIAL COMPUTATION, IWINAC 2011, PART II, 2011, 6687 : 87 - 95
  • [36] Radiolabeling and Quantitative In Vivo SPECT/CT Imaging Study of Liposomes Using the Novel Iminothiolane-99mTc-Tricarbonyl Complex
    Varga, Zoltan
    Szigyarto, Imola Cs.
    Gyurko, Istvan
    Doczi, Rita
    Horvath, Ildiko
    Mathe, Domokos
    Szigeti, Krisztian
    CONTRAST MEDIA & MOLECULAR IMAGING, 2017,
  • [37] MULTI-MODAL IMAGING FEATURES AND LYMPHO-VENOUS SHUNT FOR VAGINAL CHYLOUS FISTULA IN LYMPHANGIOLEIOMYOMATOSIS: CASE-REPORT AND REVIEW
    Huo, M.
    Wang, Z. -C.
    Yue, Y. -L.
    Dong, J.
    Wen, Z.
    Xin, J. -F.
    LYMPHOLOGY, 2017, 50 (03) : 136 - 140
  • [38] Image synthesis-based multi-modal image registration framework by using deep fully convolutional networks
    Liu, Xueli
    Jiang, Dongsheng
    Wang, Manning
    Song, Zhijian
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (05) : 1037 - 1048
  • [39] Diagnostic role of 99Tcm-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases
    Chen, Xiao-Liang
    Li, Qian
    Cao, Lin
    Jiang, Shi-Xi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (12): : 5336 - 5341
  • [40] Quantitative imaging of iodine-131 distributions in brain tumors with pinhole SPECT: A phantom study
    Smith, MF
    Gilland, DR
    Coleman, RE
    Jaszczak, RJ
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 856 - 864