ROC study and SUV threshold using quantitative multi-modal SPECT for bone imaging

被引:19
|
作者
Vija, A. H. [1 ]
Bartenstein, P. A. [4 ]
Froelich, J. W. [3 ]
Kuwert, T. [2 ]
Macapinlac, H. [5 ]
Daignault, C. P. [3 ,8 ]
Gowda, N. [3 ,9 ]
Hadjiev, O. [3 ,10 ]
Hephzibah, J. [6 ,7 ]
Huang, P. [6 ]
Ilhan, H. [4 ]
Jessop, A. [5 ,11 ]
Cachovan, M. [12 ]
Ma, J. [1 ]
Ding, X. [1 ]
Spence, D. [1 ]
Platsch, G. [12 ]
Szabo, Z. [6 ]
机构
[1] Siemens Med Solut USA Inc, Mol Imaging, Hoffman Estates, IL 60192 USA
[2] Friedrich Alexander Univ Erlangen, Erlangen, Germany
[3] Univ Minnesota, Minneapolis, MN USA
[4] Ludwig Maximilians Univ Munchen, Munich, Germany
[5] MD Anderson Canc Ctr, Houston, TX USA
[6] Johns Hopkins Univ, Baltimore, MD USA
[7] Christian Med Coll & Hosp, Vellore, Tamil Nadu, India
[8] Vet Med Ctr, Minneapolis, MN USA
[9] Consulting Radiol, Edina, MN USA
[10] Milwaukee Radiologists, Greenfield, WI USA
[11] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[12] Siemens Healthineers GmbH, Erlangen, Germany
来源
EUROPEAN JOURNAL OF HYBRID IMAGING | 2019年 / 3卷 / 01期
关键词
SPECT; CT; Quantitative SPECT; xSPECT quant; xSPECT bone; Bone imaging; Concordance; ROC; AUC; SUV; Tc99m; MDP; DPD; Diphosphonate;
D O I
10.1186/s41824-019-0057-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe investigated the clinical performance of a quantitative multi-modal SPECT/CT reconstruction platform for yielding radioactivity concentrations of bone imaging with Tc-99m-methylene diphosphonate (MDP) or Tc-99m-dicarboxypropane diphosphonate (DPD). The novel reconstruction incorporates CT-derived tissue information while preserving the delineation of tissue boundaries. We assessed image-based reader concordance and confidence, and determined lesion classification and SUV thresholds from ROC analysis.MethodsSeventy-two cancer patients were scanned at three US and two German clinical sites, each contributing two experienced board-certified nuclear medicine physicians as readers. We compared four variants of the reconstructed data resulting from the Flash3D (F3D) and the xSPECT Bone (TM) (xB) iterative reconstruction methods and presented images to the readers with and without a fused CT, resulting in four combinations. We used an all-or-none approach for inclusion, compiling results only when a reader completed all reads in a subset. After the final read, we conducted a "surrogate truth" reading, presenting all data to each reader. For any remaining discordant lesions, we conducted a consensus read. We next undertook ROC analysis to determine SUV thresholds for differentiating benign and lesional uptake.ResultsOn a five-point rating scale of image quality, xB was deemed better by almost two points in resolution and one point better in overall acceptance compared to F3D. The absolute agreement of the rendered decision between the nine readers was significantly higher with CT information either inside the reconstruction (xB, xBCT) or simply through image fusion (F3DCT): 0.70 (xBCT), 0.67 (F3DCT), 0.64 (xB), and 0.46 (F3D). The confidence level to characterize the lesion was significantly higher (3.03x w/o CT, 1.32x w/CT) for xB than for F3D. There was high correlation between xB and F3D scores for lesion detection and classification, but lesion detection confidence was 41% higher w/o CT, and 21% higher w/CT for xB compared to F3D. Without CT, xB had 6.6% higher sensitivity, 7.1% higher specificity, and 6.9% greater AUC compared to F3D, and similarly with CT-fusion. The overall SUV-criterion (SUVc) of xB (12) exceeded that for xSPECT Quant (TM) (xQ; 9), an approach not using the tissue delineation of xB. SUV critical numbers depended on lesion volume and location. For non-joint lesions >6 ml, the AUC for xQ and xB was 94%, with SUVc>9.28 (xQ) or >9.68 (xB); for non-joint lesions <= 6 ml, AUCs were 81% (xQ) and 88% (xB), and SUVc>8.2 (xQ) or >9.1 (xB). For joint lesions, the AUC was 80% (xQ) and 83% (xB), with SUVc>8.61 (xQ) or >13.4 (xB).ConclusionThe incorporation of high-resolution CT-based tissue delineation in SPECT reconstruction (xSPECT Bone) provides better resolution and detects smaller lesions (6 ml), and the CT component facilitates lesion characterization. Our approach increases confidence, concordance, and accuracy for readers with a wide range of experience. The xB method retained high reading accuracy, despite the unfamiliar image presentation, having greatest impact for smaller lesions, and better localization of foci relative to bone anatomy. The quantitative assessment yielded an SUV-threshold for sensitively distinguishing benign and malignant lesions. Ongoing efforts shall establish clinically usable protocols and SUV thresholds for decision-making based on quantitative SPECT.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Development and feasibility of quantitative dynamic cardiac imaging for mice using μSPECT
    Guerraty, M. A.
    Johnson, L. C.
    Blankemeyer, E.
    Rader, D. J.
    Moore, S. C.
    Metzler, S. D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2647 - 2656
  • [22] Multi-modal medical image fusion using improved dual-channel PCNN
    Sinha, Adarsh
    Agarwal, Rahul
    Kumar, Vinay
    Garg, Nitin
    Pundir, Dhruv Singh
    Singh, Harsimran
    Rani, Ritu
    Panigrahy, Chinmaya
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (09) : 2629 - 2651
  • [23] Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies
    Kilby, Seth
    Fletcher, Jack
    Avachat, Ashish
    Jin, Zhongmin
    Imholte, Devin
    Woolstenhulme, Nicolas
    Lee, Hyoung-Koo
    Graham, Joseph
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1045
  • [24] Computer-aided modelling of three-dimensional maxillofacial tissues through multi-modal imaging
    Barone, Sandro
    Paoli, Alessandro
    Razionale, Armando V.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H2) : 89 - 104
  • [25] Deep learning architectures for Parkinson's disease detection by using multi-modal features
    Pahuja, Gunjan
    Prasad, Bhanu
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 146
  • [26] Assessment of SPECT-CT fusion images and semi-quantitative evaluation using SUV in 123I-IMP SPECT in patients with choroidal melanoma
    Kana Yamazaki
    Ryuichi Nishii
    Takamasa Maeda
    Hirokazu Makishima
    Goro Kasuya
    Tachen Chang
    Kentaro Tamura
    Masaru Wakatsuki
    Hiroshi Tsuji
    Koji Murakami
    Tatsuya Higashi
    Annals of Nuclear Medicine, 2020, 34 : 864 - 872
  • [27] Assessment of SPECT-CT fusion images and semi-quantitative evaluation using SUV in123I-IMP SPECT in patients with choroidal melanoma
    Yamazaki, Kana
    Nishii, Ryuichi
    Maeda, Takamasa
    Makishima, Hirokazu
    Kasuya, Goro
    Chang, Tachen
    Tamura, Kentaro
    Wakatsuki, Masaru
    Tsuji, Hiroshi
    Murakami, Koji
    Higashi, Tatsuya
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (11) : 864 - 872
  • [28] Non-invasive imaging assisted CFD simulation of 4D multi-modal fluid flow using in-situ adaptor
    Vaishali Sharma
    Snehlata Shakya
    Arpit Kumar
    Mayank Goswami
    Discover Applied Sciences, 7 (5)
  • [29] Extraosseous Findings on Bone Scintigraphy Using Fusion SPECT/CT and Correlative Imaging
    Wale, Daniel J.
    Wong, Ka Kit
    Savas, Hatice
    Kandathil, Asha
    Piert, Morand
    Brown, Richard K. J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 160 - 172
  • [30] Interest of multi-modal imaging in bilateral lesions of basal ganglia: A case report of a post-anoxic dystonia
    David, Pierre-Maxime
    Icard, Nicolas
    Gauvrit, Jean-Yves
    Verin, Marc
    Le Jeune, Florence
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (11) : 2098 - 2099