2,2′,3,4-Tetrahydroxy-3′-sulpho-5′-nitroazobenzene for spectrophotometric determination of aluminium in pharmaceutical suspensions and granite

被引:34
作者
Guray, T
Uysal, ÜD
Gedikbey, T
Huseyinli, AA
机构
[1] Anadolu Univ, Fac Sci, Dept Chem, Eskisehir, Turkey
[2] Osmangazi Univ, Fac Arts & Sci, Dept Chem, Eskisehir, Turkey
[3] Baku State Univ, Fac Chem, Baku, Azerbaijan
关键词
aluminium; 2,2 ',3,4-Tetrahydroxy-3 '-sulpho-5 '-nitroazobenzene; tetrahydroxyazon SN; spectrophotometric determination; granite; phannaceutical analysis;
D O I
10.1016/j.aca.2005.04.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive new spectrophotometric method has been developed for the determination of aluminium.2,2',3,4-Tetrahydroxyy-3'-sulpho-5'-nitroaobenzene (tetrahydroxyazon SN) formed an orange chelate with aluminium at pH 4. Molar absorptivity of the complex in 1:2 is 5.46 x 10(4) l mol(-1) cm(-1) at 479 nm. The method obeys Beer's law in the range of 0.005-1.079 mu g ml(-1). The determination of aluminium is not interfered with by earth alkaline, alkaline elements, rare earth elements, halides, phosphates, sulphates, urea, ascorbic acid, Sn2+, Sr2+, Cr3+, Cd2+, Hg2+, 'Mn2+. The proposed method is rapid and simple, and it has been succes or successfully applied to the determination of aluminium in certified pharmaceutieal suspension and granite. (c) 2005 Elsevier B.V. Ail rights reserved.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 44 条
[1]  
AKHMEDLI MK, 1980, AZERBAIDZHANSKII KHI, V6, P11
[2]  
ALIYEVA RA, 1987, AZERBAIDZHANSKII KHI, V2, P85
[3]   ALUMINUM INTOXICATION FROM ALUMINUM-CONTAINING PHOSPHATE BINDERS IN CHILDREN WITH AZOTEMIA NOT UNDERGOING DIALYSIS [J].
ANDREOLI, SP ;
BERGSTEIN, JM ;
SHERRARD, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (17) :1079-1084
[4]   The future of aluminum chemistry [J].
Atwood, DA ;
Yearwood, BC .
JOURNAL OF ORGANOMETALLIC CHEMISTRY, 2000, 600 (1-2) :186-197
[5]   Spectrophotometric determination of aluminium and nickel [J].
Carpani, I ;
Scavetta, E ;
Tonelli, D .
ANNALI DI CHIMICA, 2004, 94 (5-6) :365-372
[6]   Flotation spectrophotometric determination of aluminum with alizarin [J].
Chamsaz, M ;
Zavar, MHA ;
Hosseini, MS .
ANALYTICAL LETTERS, 2000, 33 (08) :1625-1633
[7]   Voltammetric determination of aluminum(III) using a reagentless sensor fabricated by sol-gel process [J].
Di, JW ;
Bi, SP ;
Yang, TY ;
Zhang, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3) :468-473
[8]  
DONWNARD AJ, 1992, ANAL CHIM ACTA, V262, P339
[9]  
FERNANDEZSOTO I, 1986, NEFROLOGIA, V6, P3
[10]  
GAMBAROV DG, 1985, ZH NEORG KHIM+, V30, P925