Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet

被引:55
作者
Chen, YG [1 ]
Yuan, XL [1 ]
机构
[1] Xian Jiaotong Univ, Dept Refrigerat & Cryogen Engn, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
air curtains; refrigerated display cabinets; experimental study;
D O I
10.1016/j.jfoodeng.2004.08.016
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments were conducted to study the effects of several important factors on the performance of a refrigerated display cabinet, including ambient air temperature, indoor relative humidity, ambient air flow, air supply velocity, air flow from perforated back panels and night covers. Both inside temperature distribution and heat load were investigated. Furthermore, the thermal entrainment factor is correlated with Reynolds number and Richardson number. The results show the thermal entrainment tends to increase with increasing momentum force but decrease when the gravitational force is dominant. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 9 条
  • [1] American Society of Heating Refrigeration and Air-Conditioning Engineers(ASHRAE), 1998, ASHRAE HDB REFR
  • [2] ASHRAE, 2001, ASHRAE FUNDAMENTALS
  • [3] *EUR STAND, 2001, 4412 EN
  • [4] FIELD B, 2001, P ASME FEDSM 2001 MA
  • [5] HOWELL RH, 1993, ASHRAE TRAN, V99, P667
  • [6] Howell RH, 1976, ASHRAE T, V82, P191
  • [7] Li W., 1997, THEORIES APPL BUOYAN
  • [8] The application of advance methods in analyzing the performance of the air curtain in a refrigerated display case
    Navaz, HK
    Faramarzi, R
    Gharib, M
    Dabiri, D
    Modarress, D
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 756 - 764