Solid-phase radioimmunoassay and chemiluminoimmunoassay for somatostatin in unextracted rat plasma

被引:1
|
作者
Leidy, JW
Daniels, KL
Millard, WJ
机构
[1] HUNTINGTON VA MED CTR,MED SERV,HUNTINGTON,WV 25704
[2] HUNTINGTON VA MED CTR,RES SERV,HUNTINGTON,WV 25704
[3] UNIV FLORIDA,J HILLIS MILLER HLTH CTR,COLL PHARM,DEPT PHARMACOCHEM,GAINESVILLE,FL 32610
关键词
somatostatin; radioimmunoassay; chemiluminescence; immunoassay; acridinium; rat; hypophysial portal circulation; hypothalamus;
D O I
10.1016/0165-0270(96)00038-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of somatostatin (SS) in small microliter volumes of rat plasma obtained from the hypophysial portal circulation would be aided by a sensitive and robust technique not dependent on extraction. We have developed radioimmunoassay (RIA) and chemiluminoimmunoassay (CIA) for SS in unextracted rat plasma from a previously described solid-phase method in human plasma. Plasma SS was captured by primary antibody bound to second antibody coated polystyrene bead. After incubation the bead was washed and [I-125]Tyr(1)-SS added. Following overnight incubation and washing, the bead was counted. The sensitivity for 50 mu l plasma was 11 pg/ml. Parallel displacement with abdominal portal and hypophysial portal plasma was demonstrated. For direct CIA, SS was labeled with acridinium and purified using 2 sequential gradient elutions on reversed-phase HPLC. Labeled SS performed satisfactorily in solution CIA, but did not bind well in solid-phase CIA. Hence, an indirect CIA using biotinylated SS and quantitation by acridinium labeled streptavidin was established with equivalent performance to solid-phase RIA. In summary, we have developed and validated sensitive and robust solid-phase RIA and indirect CIA for SS in unextracted rat plasma. This solid-phase method could serve as a universal system for the measurement of other neuropeptides in rat plasma.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [31] SIMPLIFIED SOLID-PHASE IMMUNOBEAD ASSAY FOR DETECTION OF CIGUATOXIN AND RELATED POLYETHERS
    HOKAMA, Y
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1990, 4 (03) : 213 - 217
  • [32] Determination of Folic Acid by Solid-Phase Extraction and Flow Injection Chemiluminescence
    Zhao, Shi-Hao
    Zhang, Ping-Ping
    Zhao, Shi-Bin
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (10) : 7557 - 7562
  • [33] Chemiluminescence Determination of Benzoic Acid Using A Solid-Phase Verdigris Reactor
    Zhen Jun WANG*
    Chinese Chemical Letters, 2003, (03) : 283 - 286
  • [34] Chemiluminescence determination of benzoic acid using a solid-phase verdigris reactor
    Wang, ZJ
    Song, ZH
    CHINESE CHEMICAL LETTERS, 2003, 14 (03) : 283 - 286
  • [35] Molecularly imprinted solid-phase extraction sorbent for selective determination of melatonin
    Esen, Elif
    Osman, Bilgen
    Demir, M. Nalan
    MICROCHEMICAL JOURNAL, 2021, 170
  • [36] Effects of 5-HT agonists, selective for different receptor subtypes, on oxytocin, CCK, gastrin and somatostatin plasma levels in the rat
    UvnasMoberg, K
    Hillegaart, V
    Alster, P
    Ahlenius, S
    NEUROPHARMACOLOGY, 1996, 35 (11) : 1635 - 1640
  • [37] A rapid and specific approach for direct measurement of donepezil concentration in human plasma by LC-MS/MS employing solid-phase extraction
    Shah, Hiten J.
    Kundlik, Mohan L.
    Pandya, Ankit
    Prajapati, Shivkurnar
    Subbaiah, Gunta
    Patel, Chhagan N.
    Patel, Dasharath M.
    Suhagiya, Bhanu N.
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) : 141 - 151
  • [38] Production and Characterization of Anti-LH Polyclonal Antibodies for Establishment of Sepharose Solid Phase Radioimmunoassay
    Ebeid, N. H.
    Mehany, N. L.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2016, 49 (04): : 251 - 263
  • [39] A Photochemical Ligation System Enabling Solid-Phase Chemiluminescence Read-Out
    Delafresnaye, Laura
    Schmitt, Christian W.
    Barner, Leonie
    Barner-Kowollik, Christopher
    CHEMISTRY-A EUROPEAN JOURNAL, 2019, 25 (54) : 12538 - 12544
  • [40] Magnetic polysiloxane-polyvinyl alcohol composite as solid-phase in chemiluminescent assays
    Coêlho, RAL
    Jaques, GA
    Barbosa, AD
    Velazquez, G
    Montenegro, SML
    Azevedo, WM
    Carvalho, LB
    BIOTECHNOLOGY LETTERS, 2002, 24 (20) : 1705 - 1708