Solid-phase radioimmunoassay and chemiluminoimmunoassay for somatostatin in unextracted rat plasma

被引:1
|
作者
Leidy, JW
Daniels, KL
Millard, WJ
机构
[1] HUNTINGTON VA MED CTR,MED SERV,HUNTINGTON,WV 25704
[2] HUNTINGTON VA MED CTR,RES SERV,HUNTINGTON,WV 25704
[3] UNIV FLORIDA,J HILLIS MILLER HLTH CTR,COLL PHARM,DEPT PHARMACOCHEM,GAINESVILLE,FL 32610
关键词
somatostatin; radioimmunoassay; chemiluminescence; immunoassay; acridinium; rat; hypophysial portal circulation; hypothalamus;
D O I
10.1016/0165-0270(96)00038-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of somatostatin (SS) in small microliter volumes of rat plasma obtained from the hypophysial portal circulation would be aided by a sensitive and robust technique not dependent on extraction. We have developed radioimmunoassay (RIA) and chemiluminoimmunoassay (CIA) for SS in unextracted rat plasma from a previously described solid-phase method in human plasma. Plasma SS was captured by primary antibody bound to second antibody coated polystyrene bead. After incubation the bead was washed and [I-125]Tyr(1)-SS added. Following overnight incubation and washing, the bead was counted. The sensitivity for 50 mu l plasma was 11 pg/ml. Parallel displacement with abdominal portal and hypophysial portal plasma was demonstrated. For direct CIA, SS was labeled with acridinium and purified using 2 sequential gradient elutions on reversed-phase HPLC. Labeled SS performed satisfactorily in solution CIA, but did not bind well in solid-phase CIA. Hence, an indirect CIA using biotinylated SS and quantitation by acridinium labeled streptavidin was established with equivalent performance to solid-phase RIA. In summary, we have developed and validated sensitive and robust solid-phase RIA and indirect CIA for SS in unextracted rat plasma. This solid-phase method could serve as a universal system for the measurement of other neuropeptides in rat plasma.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [1] A SENSITIVE RADIOIMMUNOASSAY, INCORPORATING SOLID-PHASE EXTRACTION, FOR FLUTICASONE 17-PROPIONATE IN PLASMA
    BAIN, BM
    HARRISON, G
    JENKINS, KD
    PATEMAN, AJ
    SHENOY, EVB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (07) : 557 - 561
  • [2] A SENSITIVE RADIOIMMUNOASSAY, COMBINED WITH SOLID-PHASE EXTRACTION, FOR THE SUBNANOGRAM PER ML DETERMINATION OF ONDANSETRON IN HUMAN PLASMA
    WRING, SA
    ROONEY, RM
    GODDARD, CP
    WATERHOUSE, I
    JENNER, WN
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (03) : 361 - 371
  • [3] Development, optimization, and validation of magnetic solid-phase radioimmunoassay for estimation of luteinizing hormone
    Ayoub S.M.
    Radiochemistry, 2014, 56 (1) : 66 - 71
  • [4] A radioimmunoassay combined with solid-phase extraction for the determination (pg ml-1) of AR-C15849XX in human plasma
    Willson, VJC
    Preston, JR
    Lockley, WJS
    Singh, J
    Wilkinson, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) : 793 - 800
  • [5] A radioimmunoassay combined with solid-phase extraction for the determination of a novel anti-obesity agent, ARL 15849XX, in dog plasma
    Willson, VJC
    Preston, JR
    Lockley, WJS
    Singh, J
    Wilkinson, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (05) : 593 - 600
  • [6] Use of solid-phase double-antibody radioimmunoassay to identify species from small skeletal fragments
    Ubelaker, DH
    Lowenstein, JM
    Hood, DG
    JOURNAL OF FORENSIC SCIENCES, 2004, 49 (05) : 924 - 929
  • [7] POLYACROLEIN LATEX AS A SOLID-PHASE CARRIER FOR RADIOIMMUNOASSAY - COMPARISON WITH MICROCRYSTALLINE CELLULOSE AND POLYSTYRENE TEST-TUBE SURFACE
    ZHOROV, OV
    PREYGERZON, VA
    LUKIN, YV
    ZUBOV, VP
    MARTSEV, SP
    BIOORGANICHESKAYA KHIMIYA, 1995, 21 (04): : 261 - 267
  • [8] Radioimmunochemical studies for development of a solid-phase radioimmunoassay system using coated beads for the assessment of human chorionic gonadotropin
    Sallam K.M.
    El-Bayoumy A.S.A.
    Mehany N.L.
    Radiochemistry, 2017, 59 (2) : 181 - 187
  • [9] EVALUATION OF A NEW REACTIVE SOLID-PHASE FOR RADIOIMMUNOASSAY OF SERUM SPECIFIC IGE AGAINST MUSCLE-RELAXANT DRUGS
    GUEANT, JL
    MATA, E
    MONIN, B
    MONERETVAUTRIN, DA
    KAMEL, L
    NICOLAS, JP
    LAXENAIRE, MC
    ALLERGY, 1991, 46 (06) : 452 - 458
  • [10] Use of a solid-phase extraction with radioimmunoassay to identify the proportional bias of clinical B-type natriuretic peptide immunoassay: the impact of plasma matrix and antibody multispecificity
    Naik, George O. A.
    Moe, Gordon W.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (10) : 1353 - 1359