Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia

被引:35
作者
Davis, Georgia M. [1 ]
Galindo, Rodolfo J. [1 ]
Migdal, Alexandra L. [1 ]
Umpierrez, Guillermo E. [1 ]
机构
[1] Emory Univ, Dept Med, 69 Jesse Hill Jr Dr Southeast,Glenn Mem Bldg, Atlanta, GA 30303 USA
基金
美国国家卫生研究院;
关键词
Diabetes; Technology; Inpatient; Hospital; Glycemic control; RANDOMIZED CONTROLLED-TRIAL; GLUCOSE MONITORING-SYSTEM; CRITICALLY-ILL PATIENTS; TIGHT GLYCEMIC CONTROL; LOOP INSULIN DELIVERY; HOSPITALIZED-PATIENTS; CLOSED-LOOP; AMERICAN ASSOCIATION; TIME; PROTOCOL;
D O I
10.1016/j.ecl.2019.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In past decades, a rapid evolution of diabetes technology led to increased popularity and use of continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion (CSII) in the ambulatory setting for diabetes management, and recently, the artificial pancreas became available. Efforts to translate this technology to the hospital setting have shown accuracy and reliability of CGM, safety of CSII in appropriate populations, improvement of inpatient glycemic control with computerized glycemic management systems, and feasibility of inpatient CGM-CSII closed-loop systems. Several ongoing studies are focusing on continued translation of this technology to improve glycemic control and outcomes in hospitalized patients.
引用
收藏
页码:79 / +
页数:16
相关论文
共 52 条
  • [1] Aloi Joseph, 2017, J Diabetes Sci Technol, V11, P12, DOI 10.1177/1932296816664746
  • [2] Diabetes Care in the Hospital: Standards of Medical Care in Diabetes-2019
    Cefalu, William T.
    Berg, Erika Gebel
    Saraco, Mindy
    Petersen, Matthew P.
    Uelmen, Sacha
    Robinson, Shamera
    [J]. DIABETES CARE, 2019, 42 : S173 - S181
  • [3] Fully closed-loop insulin delivery improves glucose control of inpatients with type 2 diabetes receiving hemodialysis
    Bally, Lia
    Gubler, Philipp
    Thabit, Hood
    Hartnell, Sara
    Ruan, Yue
    Wilinska, Malgorzata E.
    Evans, Mark L.
    Semmo, Mariam
    Vogt, Bruno
    Coll, Anthony P.
    Stettler, Christoph
    Hovorka, Roman
    [J]. KIDNEY INTERNATIONAL, 2019, 96 (03) : 593 - 596
  • [4] Closed-Loop Insulin Delivery for Glycemic Control in Noncritical Care
    Bally, Lia
    Thabit, Hood
    Hartnell, Sara
    Andereggen, Eveline
    Ruan, Yue
    Wilinska, Malgorzata E.
    Evans, Mark L.
    Wertli, Maria M.
    Coll, Anthony P.
    Stettler, Christoph
    Hovorka, Roman
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2018, 379 (06) : 547 - 556
  • [5] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [6] Computer-based insulin infusion protocol improves glycemia control over manual protocol
    Boord, Jeffrey B.
    Sharifi, Mona
    Greevy, Robert A.
    Griffin, Marie R.
    Lee, Vivian K.
    Webb, Ty A.
    May, Michael E.
    Waitman, Lemuel R.
    May, Addison K.
    Miller, Randolph A.
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2007, 14 (03) : 278 - 287
  • [7] Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial
    Boughton, Charlotte K.
    Bally, Lia
    Martignoni, Franco
    Hartnell, Sara
    Herzig, David
    Vogt, Andreas
    Wertli, Maria M.
    Wilinska, Malgorzata E.
    Evans, Mark L.
    Coll, Anthony P.
    Stettler, Christoph
    Hovorka, Roman
    [J]. LANCET DIABETES & ENDOCRINOLOGY, 2019, 7 (05) : 368 - 377
  • [8] Brief Report: Comparison of Continuous Glucose Monitoring and Finger-Prick Blood Glucose Levels in Hospitalized Patients Administered Basal-Bolus Insulin
    Burt, Morton G.
    Roberts, Gregory W.
    Aguilar-Loza, Norma R.
    Stranks, Stephen N.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (03) : 241 - 245
  • [9] Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time
    Chee, F
    Fernando, T
    van Heerden, PV
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2003, 7 (01): : 43 - 53
  • [10] Clarke SE, 2012, BRIT J BIOMED SCI, V69, P83