Validated method for the determination of ethylglucuronide and ethylsulfate in human urine

被引:13
作者
Beyer, Jochen [1 ]
Vo, Tu N. [1 ]
Gerostamoulos, Dimitri [1 ]
Drummer, Olaf H. [1 ]
机构
[1] Monash Univ, Victorian Inst Forens Med, Dept Forens Med, Melbourne, Vic 3006, Australia
关键词
Ethylglucuronide; Ethylsulfate; Urine; Liquid chromatography; Mass spectrometry; IONIZATION/TANDEM MASS-SPECTROMETRY; PRESSURE CHEMICAL-IONIZATION; HUMAN BLOOD-PLASMA; LC-APCI-MS; ETHYL SULFATE; ETHANOL METABOLITE; CONFIRMATORY ANALYSIS; ALCOHOL-CONSUMPTION; GLUCURONIDE; MARKERS;
D O I
10.1007/s00216-011-4667-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Detection of the alcohol metabolites ethylglucuronide (EtG) and ethylsulfate (EtS) has become routine in many forensic laboratories over the last few years. Most previously published methods using liquid chromatography coupled with electrospray tandem mass spectrometry require a post-chromatographic addition of solvent and/or extensive sample preparation prior to analysis. The aim of the study was to develop a simplified method. To 20 mu L urine, internal standard containing EtG-d5 and EtS-d (5) was added and the mixture was treated with elution buffer internal standard. EtG and EtS were separated using a Shimadzu Prominence high performance liquid chromatography (HPLC) system with a C18 separation column (Restek Ultra Aqueous C18, 4.6 x 150 mm, 5 mu m), using isocratic elution with a mobile phase consisting of 10 mM ammonium acetate buffer pH 7 (total run time, 6 min). The compounds were detected using an Applied Biosystems API 5000 liquid chromatography tandem mass spectrometry system (atmospheric pressure chemical ionization, multiple-reaction monitoring mode). The method was fully validated according to international guidelines. The assay was found to be selective for the compounds of interest. It was linear from 0.1 to 10 mg/L for all analytes (R (2) > 0.99). Matrix effects studies showed the presence of a slight but consistent ion enhancement (n = 10 different urine samples) at low concentrations and no effects at higher concentrations. Accuracy data were between 0.75% and 8.1% bias for EtG and between -5.0% and -11.3% bias for EtS. Precision data were between 4.3% and 6.9% relative standard deviations (RSD) for EtG and between 6.0% and 7.5% RSD for EtS. No instability was observed after repeated freezing and thawing. This fast, reliable, and accurate method enables the detection and quantification of alcohol metabolites in urine. The method is easier to use and more sensitive than previously published methods.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[2]   Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS [J].
Beyer, Jochen ;
Peters, Frank T. ;
Kraemer, Thomas ;
Maurer, Hans H. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05) :621-633
[3]   Detection and validated quantification of nine herbal phenalkylamines and methcathinone in human blood plasma by LC-MS/MS with electrospray ionization [J].
Beyer, Jochen ;
Peters, Frank T. ;
Kraemer, Thomas ;
Maurer, Hans H. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (02) :150-160
[4]   validated method for the determination of the ethanol consumption markers ethyl glucuronide, ethyl phosphate, and ethyl sulfate in human urine by reversed-phase/weak anion exchange liquid chromatography-tandem mass spectrometry [J].
Bicker, Wolfgang ;
Laemmerhofer, Michael ;
Keller, Thomas ;
Schuhmacher, Rainer ;
Krska, Rudolf ;
Lindner, Wolfgang .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5884-5892
[5]   Detection of recent ethanol intake with new markers: Comparison of fatty acid ethyl esters in serum and of ethyl glucuronide and the ratio of 5-hydroxytryptophol to 5-hydroxyindole acetic acid in urine [J].
Borucki, K ;
Schreiner, R ;
Dierkes, J ;
Jachau, K ;
Krause, D ;
Westphal, S ;
Wurst, FM ;
Luley, C ;
Schmidt-Gayk, H .
ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2005, 29 (05) :781-787
[6]   Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses [J].
Chambers, Erin ;
Wagrowski-Diehl, Diane M. ;
Lu, Ziling ;
Mazzeo, Jeffrey R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :22-34
[7]   Forensic confirmatory analysis of ethyl sulfate - A new marker for alcohol consumption - by liquid-chromatography/electrospray ionization/tandem mass spectrometry [J].
Dresen, S ;
Weinmann, W ;
Wurst, FM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (11) :1644-1648
[8]   Determination of ethyl sulfate -: a marker for recent ethanol consumption -: in human urine by CE with indirect UV detection [J].
Esteve-Turrillas, Francesc A. ;
Bicker, Wolfgang ;
Laemmerhofer, Michael ;
Keller, Thomas ;
Lindner, Wolfgang .
ELECTROPHORESIS, 2006, 27 (23) :4763-4771
[9]   A novel and an effective analytical approach for the LC-MS determination of ethyl glucuronide and ethyl sulfate in urine [J].
Favretto, Donata ;
Nalesso, Alessandro ;
Frison, Giampietro ;
Viel, Guido ;
Traldi, Pietro ;
Ferrara, Santo Davide .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2010, 124 (02) :161-164
[10]   No-discharge atmospheric pressure chemical ionization mass spectrometry of ethyl glucuronide and ethyl sulfate [J].
Favretto, Donata ;
Nalesso, Alessandro ;
Frison, Giampietro ;
Viel, Guido ;
Traldi, Pietro ;
Ferrara, Santo Davide .
JOURNAL OF MASS SPECTROMETRY, 2010, 45 (01) :121-124