Angiogenesis of renal cell carcinoma: perfusion CT findings

被引:66
作者
Chen, Yan [1 ,2 ]
Zhang, Jin [1 ,2 ]
Dai, Jingrui [1 ,2 ]
Feng, Xiaoli [2 ,3 ]
Lu, Haizhen [2 ,3 ]
Zhou, Chunwu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Canc Hosp & Inst, Dept Diagnost Radiol, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, Beijing 100021, Peoples R China
[3] Chinese Acad Med Sci, Canc Hosp & Inst, Dept Pathol, Beijing 100037, Peoples R China
来源
ABDOMINAL IMAGING | 2010年 / 35卷 / 05期
关键词
Renal cell carcinoma; Tomography; X-ray computed; Perfusion imaging; Tumor angiogenesis; Microvascular density; Vascular endothelial growth factor; TUMOR ANGIOGENESIS; MICROVESSEL DENSITY; ANTIANGIOGENIC THERAPY; PULMONARY NODULES; FUNCTIONAL-CT; ROW CT; EXPRESSION; TNP-470; GROWTH; CANCER;
D O I
10.1007/s00261-009-9565-0
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
To observe the perfusion CT findings of renal cell carcinoma (RCC) and prospectively correlate perfusion CT parameters with tumor MVD and VEGF expression. Dynamic contrast-enhanced multislice spiral CT was performed prospectively in 73 cases with histologically proven RCC (65 clear cell, 3 papillary, and 5 chromophobe). Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface-area product (PS) of RCC and normal renal cortex were measured, respectively. The tumor MVD count and VEGF expression level were determined by immunohistochemistry with specific monoclonal antibodies. There was significant difference between BF, BV, MTT, and PS of normal renal cortex (454.32 +/- A 110.90 mL/min/100 g, 23.53 +/- A 5.71 mL/100 g, 3.62 +/- A 1.38 s, 63.95 +/- A 18.85 mL/min/100 g) and RCC (261.96 +/- A 175.86 mL/min/100 g, 17.17 +/- A 8.34 mL/100 g, 7.08 +/- A 3.42 s, 25.07 +/- A 13.20 mL/min/100 g) (P < 0.01). BF and BV among RCC histologic subtypes were significantly different (P < 0.05), MTT and PS were not (P > 0.05). MVD (42.29 +/- A 21.00) of RCC is positively correlated with BF, BV, and PS (P < 0.01), not with MTT (P > 0.05). No relationship was found between the expression levels of VEGF and any perfusion CT parameter. Perfusion CT is a feasible technique to assess tissue perfusion in patients with RCC. BV, BF, and PS correlate positively with MVD and may reflect angiogenesis of RCC.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 30 条
  • [11] Dynamic CT evaluation of tumor vascularity in renal cell carcinoma
    Jin, HW
    Peng, GM
    Pei, JW
    Wei, XC
    Xiu, HZ
    Yu, W
    Xiao, HZ
    Xin, QM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) : 1423 - 1430
  • [12] Functional CT for quantifying tumor perfusion in antiangiogenic therapy in a rat model
    Kan, ZX
    Phongkitkarun, S
    Kobayashi, S
    Tang, Y
    Ellis, LM
    Lee, TY
    Charnsangavej, C
    [J]. RADIOLOGY, 2005, 237 (01) : 151 - 158
  • [13] Functional computed tomography imaging of tumor-induced angiogenesis: preliminary results of new tracer kinetic modeling using a computer discretization approach
    Kaneoya, Katsuhiko
    Ueda, Takuya
    Suito, Hiroshi
    Nanazawa, Youhei
    Tamaru, Junichi
    Isobe, Kouichi
    Naya, Yukio
    Tobe, Toyofusa
    Motoori, Ken
    Yamamoto, Seiji
    Rubin, Geoffrey D.
    Minami, Manabu
    Ito, Hisao
    [J]. RADIATION MEDICINE, 2008, 26 (04): : 213 - 221
  • [14] Early antivascular effects of bevacizumab anti-VEGF monoclonal antibody on colorectal carcinomas assessed with functional CT imaging
    Koukourakis, Michael I.
    Mavanis, Ioannis
    Kouklakis, George
    Pitiakoudis, Michael
    Minopoulos, George
    Manolas, Costantinos
    Simopoulos, Costantinos
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2007, 30 (03): : 315 - 318
  • [15] Peripheral lung carcinoma: Correlation of angiogenesis and first-pass perfusion parameters of 64-detector row CT
    Li, Yuan
    Yang, Zhi-gang
    Chen, Tian-wu
    Chen, Hui-jiao
    Sun, Jia-yu
    Lu, Yan-rong
    [J]. LUNG CANCER, 2008, 61 (01) : 44 - 53
  • [16] Tumor angiogenesis and dynamic CT in colorectal carcinoma: Radiologic-pathologic correlation
    Li, Zi-Ping
    Meng, Quan-Fei
    Sun, Can-Hui
    Xu, Da-Sheng
    Fan, Miao
    Yang, Xu-Feng
    Chen, Dong-Ying
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2005, 11 (09) : 1287 - 1291
  • [17] LZAWA J, 2001, CAN MED ASSOC J, V164, P662
  • [18] Peripheral lung cancer: relationship between multi-slice spiral CT perfusion imaging and tumor angiogenesis and cyclin D1 expression
    Ma, Shu-Hua
    Xu, Ke
    Xiao, Zhuang-Wei
    Wu, Min
    Sun, Zheng-Yu
    Wang, Zhao-Xin
    Hu, Zhi-Guo
    Dai, Xu
    Han, Ming-Jun
    Li, Yu-Guang
    [J]. CLINICAL IMAGING, 2007, 31 (03) : 165 - 177
  • [19] Peripheral pulmonary nodules: Relationship between multi-slice spiral CT perfusion imaging and tumor angiogenesis and VEGF expression
    Ma, Shu-Hua
    Le, Hong-Bo
    Jia, Bao-hui
    Wang, Zhao-Xin
    Xiao, Zhuang-Wei
    Cheng, Xiao-Ling
    Mei, Wei
    Wu, Min
    Hu, Zhi-Guo
    Li, Yu-Guang
    [J]. BMC CANCER, 2008, 8 (1)
  • [20] Correlation between tumor blood flow assessed by perfusion CT and effect of neoadjuvant therapy in advanced esophageal cancers
    Makari, Yoichi
    Yasuda, Takushi
    Doki, Yuichiro
    Miyata, Hiroshi
    Fujiwara, Yoshiyuki
    Takiguchi, Shuji
    Matsuyama, Jin
    Yamasaki, Makoto
    Hirao, Takafumi
    Koyama, Mitsuhiro Koyama
    Nakamuara, Hironobu
    Monden, Morito
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 2007, 96 (03) : 220 - 229