Capillary electrophoresis-mass spectrometry of intact basic proteins using Polybrene-dextran sulfate-Polybrene-coated capillaries: System optimization and performance

被引:56
作者
Haselberg, Rob [1 ]
de Jong, Gerhardus J. [1 ]
Somsen, Govert W. [1 ]
机构
[1] Univ Utrecht, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
关键词
Basic proteins; Capillary coating; Capillary electrophoresis; Mass spectrometry; CYTOCHROME-C; MS; PEPTIDES; COATINGS; SEPARATIONS; STATE; PH;
D O I
10.1016/j.aca.2010.08.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoresis-mass spectrometry (CE-MS) method using sheath liquid electrospray ionization interfacing was studied and optimized for the analysis of intact basic proteins. To prevent protein adsorption, capillaries with a noncovalent positively charged coating were utilized. Capillaries were coated by subsequent rinsing with solutions of Polybrene, dextran sulfate and Polybrene. The coating proved to be fully compatible with MS detection, causing no background signals and ionization suppression. The composition of the sheath liquid and BGE was optimized using the model proteins alpha-chymotrypsinogen A. ribonuclease A. lysozyme and cytochrome c. A sheath liquid of isopropanol-water-acetic acid (75:25:0.1, v/v/v) at 2 mu L min(-1) resulted in optimal signal intensities for most proteins, but caused dissociation of the heme group of cytochrome c. Optimum protein responses were obtained with a BGE of 50 mM acetic acid (pH 3.0), which allowed a baseline separation of the test protein mixture. Several minor impurities present in the mixture could be detected and provisionally identified using accurate mass and a protein modification database. The selectivity of the CE-MS system was investigated by the analysis of acetylated lysozyme. Eight highly related species, identified as non-acetylated lysozyme and lysozyme acetylated in various degrees, could be distinguished. The CE-MS system showed good reproducibility yielding interday (three weeks period) RSDs for migration time and peak area within 2% and 10%, respectively. With the CE-MS system, determination coefficients (R(2)) for protein concentration and peak area were higher than 0.996, whereas detection limits were between 11 and 19 nM. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 40 条
[1]   The methanol-induced conformational transitions of β-lactoglobulin, cytochrome c, and ubiquitin at low pH:: A study by electrospray ionization mass spectrometry [J].
Babu, KR ;
Moradian, A ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (03) :317-328
[2]   Capillary electrophoresis/mass spectrometry for the separation and characterization of bovine Cu,Zn-superoxide dismutase [J].
Borges-Alvarez, Marta ;
Benavente, Fernando ;
Barbosa, Jose ;
Sanz-Nebot, Victoria .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (10) :1411-1418
[3]   Analysis of non-covalent protein complexes by capillary electrophoresis-time-of-flight mass spectrometry [J].
Brenner-Weiss, G ;
Kirschöfer, F ;
Kühl, B ;
Nusser, M ;
Obst, U .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :147-153
[4]   Correlation between the charge of proteins in solution and in the gas phase investigated by protein charge ladders, capillary electrophoresis, and electrospray ionization mass spectrometry [J].
Carbeck, JD ;
Severs, JC ;
Gao, JM ;
Wu, QY ;
Smith, RD ;
Whitesides, GM .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (51) :10596-10601
[5]   CHARACTERIZATION OF HEME-C PEPTIDES BY MASS-SPECTROMETRY [J].
CARRAWAY, AD ;
BURKHALTER, RS ;
TIMKOVICH, R ;
PETERSON, J .
JOURNAL OF INORGANIC BIOCHEMISTRY, 1993, 52 (03) :201-207
[6]   Analysis of recombinant human growth hormone by capillary electrophoresis with bilayer-coated capillaries using UV and MS detection [J].
Catai, Jonatan R. ;
Torano, Javier Sastre ;
Jongen, Peter M. J. M. ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :160-166
[7]   Capillary electrophoresis-mass spectrometry of proteins at medium pH using bilayer-coated capillaries [J].
Catai, Jonatan R. ;
Torano, Javier Sastre ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
ANALYST, 2007, 132 (01) :75-81
[8]   Buffer additives other than the surfactant sodium dodecyl sulfate for protein separations by capillary electrophoresis [J].
Corradini, D .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 699 (1-2) :221-256
[9]   CE-MS of zein proteins from conventional and transgenic maize [J].
Erny, Guillaume L. ;
Luisa Marina, Maria ;
Cifuentes, Alejandro .
ELECTROPHORESIS, 2007, 28 (22) :4192-4201
[10]   Protein Folding and Protein-Ligand Interactions Monitored by Electrospray Mass Spectrometry [J].
Ferguson, Peter L. ;
Kuprowski, Mark C. ;
Boys, Brian L. ;
Wilson, Derek J. ;
Pan, Jingxi ;
Konermann, Lars .
CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (02) :186-204