Fidelity of Electronic Documentation for Reactions Prompting Premedication to Iodinated Contrast Media

被引:8
作者
Ananthakrishnan, Lakshmi [1 ,2 ]
Parrott, Daniel T. [3 ]
Mielke, Nathan [4 ]
Xi, Yin [3 ]
Davenport, Matthew S. [5 ,6 ,7 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, Computed Tomog, Dallas, TX USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, Abdominal Imaging Div, Dallas, TX USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[4] Baylor Scott & White Hlth Syst, Round Rock, TX USA
[5] Univ Michigan, Michigan Med, Operat, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Michigan Med, Dept Radiol, Adult Radiol, Ann Arbor, MI 48109 USA
[7] Univ Michigan, Michigan Med, Dept Urol, Adult Radiol, Ann Arbor, MI 48109 USA
关键词
Iodinated contrast; contrast allergy; premedication; medication allergy documentation; CORTICOSTEROID PROPHYLAXIS; ALLERGY; HYPERSENSITIVITY; CONSENSUS; RISK;
D O I
10.1016/j.jacr.2021.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aims of this study were to assess the fidelity of electronic health record documentation prompting premedication to iodinated contrast media and to determine the appropriateness of administered premedication on the basis of that documentation. Methods: In this retrospective quality assurance cohort study, medication adverse events recorded in electronic health records between January 1, 2018, and August 31, 2019, to "iodine," "iodine-containing products," and "iodinated contrast media" were identified (N = 4,309); entries missing documentation (n = 1,651) and breakthrough reactions (n = 22) were excluded. Reaction description, severity, and free-text comments were used to categorize each entry as concordant (documentation matches recorded severity per the ACR Manual on Contrast Media version 10.3), discordant (description-severity mismatch, agent unrelated to iodinated contrast media, not a hypersensitivity reaction), or unclear. A subset of patients undergoing premedication was identified, and premedication was categorized as appropriate, inappropriate, or unsure on the basis of the index reaction using the aforementioned framework. Descriptive statistics were calculated. Results: There were 2,636 adverse event entries in 2,441 patients: 59.9% (1,578 of 2,636) were classified as concordant, 30.2% (797 of 2,636) as discordant (n = 377 not a hypersensitivity reaction, n = 317 description-severity mismatch, and n = 103 unrelated agent), and 9.9% (n = 261) as unclear documentation. For the premedicated subset, concordance classification was feasible for 202 unique patients premedicated 335 times. Premedication was appropriate in 72% (240 of 335) and inappropriate in 22% (73 of 335); 17% of premedication events (56 of 335) were inappropriately administered for a prior physiologic reaction. Conclusions: Premedication prompts in the electronic health record are often erroneous because of inaccurate coding, incomplete data, and reaction misclassification. These errors result in inappropriate premedication for a substantial minority of patients.
引用
收藏
页码:982 / 989
页数:8
相关论文
共 25 条
[1]   Protective effect against repeat adverse reactions to iodinated contrast medium: Premedication vs. changing the contrast medium [J].
Abe, Shoko ;
Fukuda, Hozumi ;
Tobe, Kimiko ;
Ibukuro, Kenji .
EUROPEAN RADIOLOGY, 2016, 26 (07) :2148-2154
[2]  
[Anonymous], ACR MAN CONTR MED VE
[3]   Allergy entry and deletion in the electronic health record [J].
Blumenthal, Kimberly G. ;
Acker, Warren W. ;
Li, Yu ;
Holtzman, Niki S. ;
Zhou, Li .
ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2017, 118 (03) :380-381
[4]   Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions [J].
Boehm, Ingrid ;
Nairz, Knud ;
Morelli, John N. ;
Keller, Patricia Silva Hasembank ;
Heverhagen, Johannes T. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (04) :326-332
[5]   Recommendations for Standardized Documentation of Contrast Medium-Induced Hypersensitivity [J].
Boehm, Ingrid B. ;
van der Molen, Aart J. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (08) :1027-1028
[6]   Use of Intravenous Iodinated Contrast Media in Patients with Kidney Disease: Consensus Statements from the American College of Radiology and the National Kidney Foundation [J].
Davenport, Matthew S. ;
Perazella, Mark A. ;
Yee, Jerry ;
Dillman, Jonathan R. ;
Fine, Derek ;
McDonald, Robert J. ;
Rodby, Roger A. ;
Wang, Carolyn L. ;
Weinreb, Jeffrey C. .
RADIOLOGY, 2020, 294 (03) :660-668
[7]   The Evidence for and Against Corticosteroid Prophylaxis in At-Risk Patients [J].
Davenport, Matthew S. ;
Cohan, Richard H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) :413-+
[8]   Indirect Cost and Harm Attributable to Oral 13-Hour Inpatient Corticosteroid Prophylaxis before Contrast-enhanced CT [J].
Davenport, Matthew S. ;
Mervak, Benjamin M. ;
Ellis, James H. ;
Dillman, Jonathan R. ;
Dunnick, N. Reed ;
Cohan, Richard H. .
RADIOLOGY, 2016, 279 (02) :492-501
[9]   Contrast Media Controversies in 2015: Imaging Patients With Renal Impairment or Risk of Contrast Reaction [J].
Davenport, Matthew S. ;
Cohan, Richard H. ;
Ellis, James H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) :1174-1181
[10]   International Consensus on drug allergy [J].
Demoly, P. ;
Adkinson, N. F. ;
Brockow, K. ;
Castells, M. ;
Chiriac, A. M. ;
Greenberger, P. A. ;
Khan, D. A. ;
Lang, D. M. ;
Park, H. -S. ;
Pichler, W. ;
Sanchez-Borges, M. ;
Shiohara, T. ;
Thong, B. Y. -H. .
ALLERGY, 2014, 69 (04) :420-437