Gamma-H2AX biodosimetry for use in large scale radiation incidents: comparison of a rapid '96 well lyse/fix' protocol with a routine method

被引:37
作者
Moquet, Jayne [1 ]
Barnard, Stephen [1 ]
Rothkamm, Kai [1 ]
机构
[1] Publ Hlth England, Ctr Radiat Chem & Environm Hazards, Didcot, Oxon, England
来源
PEERJ | 2014年 / 2卷
关键词
Gamma-H2AX foci; DNA double-strand break; Biological dosimetry; Ionising radiation; Triage; Blood sample processing; Finger prick; HUMAN-LYMPHOCYTES; DNA-DAMAGE; EXPOSURE; ASSAY; FOCI; REPAIR; TRIAGE;
D O I
10.7717/peerj.282
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Following a radiation incident, preliminary dose estimates made by gamma-H2AX foci analysis can supplement the early triage of casualties based on clinical symptoms. Sample processing time is important when many individuals need to be rapidly assessed. A protocol was therefore developed for high sample throughput that requires less than 0.1 ml blood, thus potentially enabling finger prick sampling. The technique combines red blood cell lysis and leukocyte fixation in one step on a 96 well plate, in contrast to the routine protocol, where lymphocytes in larger blood volumes are typically separated by Ficoll density gradient centrifugation with subsequent washing and fixation steps. The rapid '96 well lyse/fix' method reduced the estimated sample processing time for 96 samples to about 4 h compared to 15 h using the routine protocol. However, scoring 20 cells in 96 samples prepared by the rapid protocol took longer than for the routine method (3.1 versus 1.5 h at zero dose; 7.0 versus 6.1 h for irradiated samples). Similar foci yields were scored for both protocols and consistent dose estimates were obtained for samples exposed to 0, 0.2, 0.6, 1.1, 1.2, 2.1 and 4.3 Gy of 250 kVp X-rays at 0.5 Gy/min and incubated for 2 h. Linear regression coefficients were 0.87 +/- 0.06 (R-2 = 97.6%) and 0.85 +/- 0.05 (R-2 = 98.3%) for estimated versus actual doses for the routine and lyse/fix method, respectively. The lyse/fix protocol can therefore facilitate high throughput processing for gamma-H2AX biodosimetry for use in large scale radiation incidents, at the cost of somewhat longer foci scoring times.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 19 条
  • [1] Inter- and intra-laboratory comparison of a multibiodosimetric approach to triage in a simulated, large scale radiation emergency
    Ainsbury, Elizabeth A.
    Al-hafidh, Jenna
    Bajinskis, Ainars
    Barnard, Stephen
    Barquinero, Joan Francesc
    Beinke, Christina
    de Gelder, Virginie
    Gregoire, Eric
    Jaworska, Alicja
    Lindholm, Carita
    Lloyd, David
    Moquet, Jayne
    Nylund, Reetta
    Oestreicher, Ursula
    Roch-Lefevre, Sandrine
    Rothkamm, Kai
    Romm, Horst
    Scherthan, Harry
    Sommer, Sylwester
    Thierens, Hubert
    Vandevoorde, Charlot
    Vral, Anne
    Wojcik, Andrzej
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2014, 90 (02) : 193 - 202
  • [2] Barber P, 2007, P SOC PHOTO-OPT INS, V6441
  • [3] BOND WW, 1978, B WORLD HEALTH ORGAN, V56, P791
  • [4] Residual DNA and chromosomal damage in ex vivo irradiated blood lymphocytes correlated with late normal tissue response to breast radiotherapy
    Chua, Melvin Lee Kiang
    Somaiah, Navita
    A'Hern, Roger
    Davies, Sue
    Gothard, Lone
    Yarnold, John
    Rothkamm, Kai
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 (03) : 362 - 366
  • [5] THE RABIT: A RAPID AUTOMATED BIODOSIMETRY TOOL FOR RADIOLOGICAL TRIAGE
    Garty, Guy
    Chen, Youhua
    Salerno, Alessio
    Turner, Helen
    Zhang, Jian
    Lyulko, Oleksandra
    Bertucci, Antonella
    Xu, Yanping
    Wang, Hongliang
    Simaan, Nabil
    Randers-Pehrson, Gerhard
    Yao, Y. Lawrence
    Amundson, Sally A.
    Brenner, David J.
    [J]. HEALTH PHYSICS, 2010, 98 (02): : 209 - 217
  • [6] Comparison of Venous and Capillary Differential Leukocyte Counts Using a Standard Hematology Analyzer and a Novel Microfluidic Impedance Cytometer
    Hollis, Veronica S.
    Holloway, Judith A.
    Harris, Scott
    Spencer, Daniel
    van Berkel, Cees
    Morgan, Hywel
    [J]. PLOS ONE, 2012, 7 (09):
  • [7] Gamma-H2AX-Based Dose Estimation for Whole and Partial Body Radiation Exposure
    Horn, Simon
    Barnard, Stephen
    Rothkamm, Kai
    [J]. PLOS ONE, 2011, 6 (09):
  • [8] Candidate protein biomarkers as rapid indicators of radiation exposure
    Horn, Simon
    Rothkamm, Kai
    [J]. RADIATION MEASUREMENTS, 2011, 46 (09) : 903 - 906
  • [9] Use of the γ-H2AX assay to monitor DNA damage and repair in cancer research
    Ivashkevich, Alesia
    Redon, Christophe E.
    Nakamura, Asako J.
    Martin, Roger F.
    Martin, Olga A.
    [J]. CANCER LETTERS, 2012, 327 (1-2) : 123 - 133
  • [10] Finger-prick blood samples can be used interchangeably with venous samples for CD4 cell counting indicating their potential for use in CD4 rapid tests
    MacLennan, Calman A.
    van Oosterhout, Joep J. G.
    White, Sarah A.
    Drayson, Mark T.
    Zijlstra, Eduard E.
    Molyneux, Malcolm E.
    [J]. AIDS, 2007, 21 (12) : 1643 - 1645