Sensitivity analysis of Monte Carlo model of a gantry-mounted passively scattered proton system

被引:5
作者
Baradaran-Ghahfarokhi, Milad [1 ]
Reynoso, Francisco [1 ]
Prusator, Michael T. [1 ]
Sun, Baozhou [1 ]
Zhao, Tianyu [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
MCNP; Monte Carlo simulation; passively scattered proton; sensitivity analysis; THERAPY; BEAM; PHYSICS; UNCERTAINTIES; SIMULATIONS; COMMITTEE;
D O I
10.1002/acm2.12803
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aimed to present guidance on the correlation between treatment nozzle and proton source parameters, and dose distribution of a passive double scattering compact proton therapy unit, known as Mevion S250. Methods All 24 beam options were modeled using the MCNPX MC code. The calculated physical dose for pristine peak, profiles, and spread out Bragg peak (SOBP) were benchmarked with the measured data. Track-averaged LET (LETt) and dose-averaged LET (LETd) distributions were also calculated. For the sensitivity investigations, proton beam line parameters including Average Energy (AE), Energy Spread (ES), Spot Size (SS), Beam Angle (BA), Beam Offset (OA), and Second scatter Offset (SO) from central Axis, and also First Scatter (FS) thickness were simulated in different stages to obtain the uncertainty of the derived results on the physical dose and LET distribution in a water phantom. Results For the physical dose distribution, the MCNPX MC model matched measurements data for all the options to within 2 mm and 2% criterion. The Mevion S250 was found to have a LETt between 0.46 and 8.76 keV.mu m(-1) and a corresponding LETd between 0.84 and 15.91 keV.mu m(-1). For all the options, the AE and ES had the greatest effect on the resulting depth of pristine peak and peak-to-plateau ratio respectively. BA, OA, and SO significantly decreased the flatness and symmetry of the profiles. The LETs were found to be sensitive to the AE, ES, and SS, especially in the peak region. Conclusions This study revealed the importance of considering detailed beam parameters, and identifying those that resulted in large effects on the physical dose distribution and LETs for a compact proton therapy machine.
引用
收藏
页码:26 / 37
页数:12
相关论文
共 26 条
[1]   Uncertainties and correction methods when modeling passive scattering proton therapy treatment heads with Monte Carlo [J].
Bednarz, Bryan ;
Lu, Hsiao-Ming ;
Engelsman, Martijn ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09) :2837-2854
[2]   Clinical consequences of relative biological effectiveness variations in proton radiotherapy of the prostate, brain and liver [J].
Carabe, Alejandro ;
Espana, Samuel ;
Grassberger, Clemens ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07) :2103-2117
[3]   Range uncertainty in proton therapy due to variable biological effectiveness [J].
Carabe, Alejandro ;
Moteabbed, Maryam ;
Depauw, Nicolas ;
Schuemann, Jan ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1159-1172
[4]   Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM [J].
Das, Indra J. ;
Cheng, Chee-Wai ;
Watts, Ronald J. ;
Ahnesjo, Anders ;
Gibbons, John ;
Li, X. Allen ;
Lowenstein, Jessica ;
Mitra, Raj K. ;
Simon, William E. ;
Zhu, Timothy C. .
MEDICAL PHYSICS, 2008, 35 (09) :4186-4215
[5]   VARIATIONS IN LINEAR ENERGY TRANSFER WITHIN CLINICAL PROTON THERAPY FIELDS AND THE POTENTIAL FOR BIOLOGICAL TREATMENT PLANNING [J].
Grassberger, Clemens ;
Trofimov, Alexei ;
Lomax, Anthony ;
Paganetti, Harald .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1559-1566
[6]   Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code [J].
Guan, Fada ;
Peeler, Christopher ;
Bronk, Lawrence ;
Geng, Changran ;
Taleei, Reza ;
Randeniya, Sharmalee ;
Ge, Shuaiping ;
Mirkovic, Dragan ;
Grosshans, David ;
Mohan, Radhe ;
Titt, Uwe .
MEDICAL PHYSICS, 2015, 42 (11) :6234-6247
[7]   Physics settings for using the Geant4 toolkit in proton therapy [J].
Jarlskog, Christina Zacharatou ;
Paganetti, Harald .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1018-1025
[8]   Proton Facility Economics: Single-Room Centers [J].
Kerstiens, John ;
Johnstone, Gregory P. ;
Johnstone, Peter A. S. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (12) :1704-1708
[9]   "Radiobiology of Proton Therapy": Results of an international expert workshop [J].
Luehr, Armin ;
von Neubeck, Claere ;
Pawelke, Joerg ;
Seidlitz, Annekatrin ;
Peitzsch, Claudia ;
Bentzen, Soren M. ;
Bortfeld, Thomas ;
Debus, Juergen ;
Deutsch, Eric ;
Langendijk, Johannes A. ;
Loeffler, Jay S. ;
Mohan, Radhe ;
Scholz, Michael ;
Sorensen, Brita S. ;
Weber, Damien C. ;
Baumann, Michael ;
Krause, Mechthild .
RADIOTHERAPY AND ONCOLOGY, 2018, 128 (01) :56-67
[10]   EchoSeed Model 6733 Iodine-125 brachytherapy source: Improved dosimetric characterization using the MCNP5 Monte Carlo code [J].
Mosleh-Shirazi, M. A. ;
Hadad, K. ;
Faghihi, R. ;
Baradaran-Ghahfarokhi, M. ;
Naghshnezhad, Z. ;
Meigooni, A. S. .
MEDICAL PHYSICS, 2012, 39 (08) :4653-4659