Hybrid renewable power plant sizing - Graphical decision tool, sensitivity analysis and applications in Ajaccio and Tilos

被引:6
作者
Duchaud, Jean-Laurent [1 ]
Notton, Gilles [1 ]
Fouilloy, Alexis [1 ]
Voyant, Cyril [2 ]
机构
[1] Univ Corsica, Res Ctr Georges Peri, UMR CNRS 6134, Corte, Corsica, France
[2] Univ La Reunion, PIMENT Lab, EA 4518, St Denis, Reunion, France
基金
欧盟地平线“2020”;
关键词
Hybrid power plant; Optimal sizing; Techno-economic study; Sensitivity analysis; Energy Management Strategies; RAMP-RATE CONTROL; ENERGY-STORAGE; BATTERY; SOLAR; SYSTEM; OPTIMIZATION; WIND; DESIGN; SIZE;
D O I
10.1016/j.apenergy.2019.113601
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
When sizing a renewable energy power plant in a grid-connected scenario, the optimal solution depends on the energy exchange rates between the actors of the electrical network. This study presents an optimization method that can be adapted to various power plant configurations to obtain the best size for each component, depending on the weather and the consumption. The optimization problem is solved in two steps. A Multi-Objective Particle Swarm Optimizer gives the trade-off between the cost of the components and the amount of non-renewable energy used, then the posttreatment takes into account the energy exchange tariffs and presents the solutions that minimize the production cost for any import and export rates. Those results can be used to evaluate the feasibility of an installation or to define the exchange tariffs with the grid regulation entity. This study also showcases the effect of the economic assumptions and of the choice of the energy management strategy on the optimal solution. The results show that the variation of the optimal production cost is limited but the component size has to be adapted accordingly. In the same way, the Energy Management Strategy used influences the plant design without affecting significantly the production cost.
引用
收藏
页数:9
相关论文
共 48 条
  • [1] A review of optimal power flow studies applied to smart grids and microgrids
    Abdi, Hamdi
    Beigvand, Soheil Derafshi
    La Scala, Massimo
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 71 : 742 - 766
  • [2] A Novel Approach for Ramp-Rate Control of Solar PV Using Energy Storage to Mitigate Output Fluctuations Caused by Cloud Passing
    Alam, M. J. E.
    Muttaqi, K. M.
    Sutanto, D.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) : 507 - 518
  • [3] [Anonymous], 2010, P INT C EN SUST DEV, DOI DOI 10.1109/ESD.2010.5598791
  • [4] [Anonymous], 2017, NVIDIA Tesla V100 GPU architecture
  • [5] [Anonymous], 2017, Tech. Rep.
  • [6] Optimal sizing of battery energy storage for micro-grid operation management using a new improved bat algorithm
    Bahmani-Firouzi, Bahman
    Azizipanah-Abarghooee, Rasoul
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 56 : 42 - 54
  • [7] Bansal AK, 2010, P IEEE INT C COMM CA, P1, DOI [10.1109/IICPE.2011, DOI 10.1109/IICPE.2011]
  • [8] Optimal sizing study of hybrid wind/PV/diesel power generation unit
    Belfkira, Rachid
    Zhang, Lu
    Barakat, Georges
    [J]. SOLAR ENERGY, 2011, 85 (01) : 100 - 110
  • [9] Optimal sizing of a nonutility-scale solar power system and its battery storage
    Cervantes, Jairo
    Choobineh, Fred
    [J]. APPLIED ENERGY, 2018, 216 : 105 - 115
  • [10] Techno-economic analysis of PV/H2 systems
    Darras, C.
    Bastien, G.
    Muselli, M.
    Poggi, P.
    Champel, B.
    Serre-Combe, P.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (30) : 9049 - 9060