Study of the Susceptibility of the GSM-R Communications Face to the Electromagnetic Interferences of the Rail Environment

被引:38
作者
Dudoyer, Stephen [1 ]
Deniau, Virginie [1 ]
Adriano, Ricardo [2 ]
Ben Slimen, M. Nedim [3 ]
Rioult, Jean [1 ]
Meyniel, Benoit [4 ]
Berbineau, Marion [1 ]
机构
[1] Univ Lille Nord France, Elect Waves & Signal Proc Res Lab Transport, French Inst Sci & Technol Transport Dev & Network, IFSTTAR,LEOST, F-59650 Villeneuve Dascq, France
[2] Univ Fed Minas Gerais, Dept Elect Engn, BR-36420 Belo Horizonte, MG, Brazil
[3] Assystem, F-75017 Paris, France
[4] Alstom, F-69627 Villeurbanne, France
关键词
Electromagnetic (EM) immunity; global system for mobile communications (GSM); GSM-railway (GSM-R); railway; telecommunication system; transient EM disturbance;
D O I
10.1109/TEMC.2011.2169677
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Global System for Mobile Communications-Railway (GSM-R) system is currently deployed in Europe in order to ensure the interoperability of the high-speed trains. Knowing that data related to control and command will be transmitted to trains through this communication system, the immunity of the GSM-R system against electromagnetic disturbances on board trains has to be certified. After a background about the GSM-R communication system, we will present in detail the typical disturbances that can affect this system in the railway environment. Significant differences between these disturbances and the test signals defined in the current European electromagnetic compatibility standards will be highlighted. The criteria that can be employed to evaluate the immunity of the GSM-R transmissions will then be discussed. Finally, new test signals and immunity test bench will be presented in order to expose the GSM-R transmissions to noise scenarios representative of the railway environment. Different immunity results will be presented and analyzed.
引用
收藏
页码:667 / 676
页数:10
相关论文
共 14 条
[1]  
Adriano R., 2008, P EMC EUR 2008 HAMB, P771
[2]  
[Anonymous], 2003, EMC REQ EACH TEL EQ
[3]  
[Anonymous], 2000, 300910 ETSI EN
[4]  
[Anonymous], 2006, EN501214 NF
[5]  
[Anonymous], 2002, 6100043 NF EN
[6]  
[Anonymous], 1995, 6100044 NF EN
[7]  
Balghiti Y., 2009, P 20 IN ZUR S EL COM, P485
[8]   Statistical characterisation of the EM interferences acting on GSM-R antennas fixed above moving trains [J].
Ben Slimen, N. ;
Deniau, V. ;
Rioult, J. ;
Dudoyer, S. ;
Baranowski, S. .
EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2009, 48 (02) :21202p1-21202p7
[9]  
Breed G., 2003, High Frequency Electronics, P46
[10]   Comparison between GSM-R coverage level and EM noise level in railway environment [J].
Hammi, T. ;
Ben Slimen, N. ;
Deniau, V. ;
Rioult, J. ;
Dudoyer, S. .
ITST: 2009 9TH INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORT SYSTEMS TELECOMMUNICATIONS, 2009, :123-+