Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey

被引:50
|
作者
Matsunaga, Yuta [1 ,2 ]
Chida, Koichi [2 ]
Kondo, Yuya [3 ]
Kobayashi, Kenichi [4 ]
Kobayashi, Masanao [5 ]
Minami, Kazuyuki [5 ]
Suzuki, Shoichi [5 ]
Asada, Yasuki [5 ]
机构
[1] Nagoya Kyoritsu Hosp, Dept Imaging, Nagoya, Aichi, Japan
[2] Tohoku Univ, Grad Sch Med, Fac Hlth Sci, Dept Radiol Technol, Sendai, Miyagi, Japan
[3] Fujita Hlth Univ, Grad Sch Hlth Sci, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ Hosp, Dept Radiol, Toyoake, Aichi, Japan
[5] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1094期
基金
日本学术振兴会;
关键词
TUBE VOLTAGE; CT;
D O I
10.1259/bjr.20180290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
引用
收藏
页数:17
相关论文
共 40 条
  • [1] Diagnostic reference levels and patient doses in computed tomography examinations in Greece
    Simantirakis, G.
    Hourdakis, C. J.
    Economides, S.
    Kaisas, I.
    Kalathaki, M.
    Koukorava, C.
    Manousaridis, G.
    Pafilis, C.
    Tritakis, P.
    Vogiatzi, S.
    Kamenopoulou, V.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) : 319 - 324
  • [2] DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY
    Benmessaoud, M.
    Dadouch, A.
    Talbi, M.
    Tahiri, M.
    El-ouardi, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 400 - 408
  • [3] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [4] Diagnostic Reference Levels for computed tomography in Austria: A 2018 nationwide survey on adult patients
    Wachabauer, David
    Roethlin, Florian
    Moshammer, Hanns Michael
    Homolka, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 125
  • [5] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Najafi, Mohsen
    Deevband, Mohammad Reza
    Ahmadi, Mohsen
    Kardan, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 603 - 609
  • [6] Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan
    Takei, Yasutaka
    Miyazaki, Osamu
    Matsubara, Kosuke
    Shimada, Yoshiya
    Muramatsu, Yoshihisa
    Akahane, Keiichi
    Fujii, Keisuke
    Suzuki, Shoichi
    Koshida, Kichiro
    PEDIATRIC RADIOLOGY, 2016, 46 (02) : 280 - 285
  • [7] Establishing Local Diagnostic Reference Levels for Head Computed Tomography Examinations
    Modlinska, Sandra
    Rojek, Marcin
    Bielowka, Michal
    Kufel, Jakub
    BIOMEDICINES, 2024, 12 (11)
  • [8] DETERMINATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS IN COMPUTED TOMOGRAPHY EXAMINATIONS OF IRAN BY A NEW QUALITY CONTROL-BASED DOSE SURVEY METHOD
    Sohrabi, Mehdi
    Parsi, Masoumeh
    Mianji, Fereidoun
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 206 - 215
  • [9] Diagnostic reference levels for computed tomography examinations in pediatric population - A systematic review
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    Pendem, Saikiran
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 845 - 852
  • [10] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766