Electropolymerized of Aniline as A New Molecularly Imprinted Polymer for Determination of Phenol A Study for Phenol Sensor

被引:0
作者
Rahmadhani, Sri [1 ]
Setiyanto, Henry [1 ]
Zulfikar, Muhammad Ali [1 ]
机构
[1] Inst Teknol Bandung, Analyt Chem Res Grp, Bandung, Indonesia
来源
2017 INTERNATIONAL SEMINAR ON SENSORS, INSTRUMENTATION, MEASUREMENT AND METROLOGY (ISSIMM) | 2017年
关键词
electrochemical sensor; molecularly imprinted polymer; carbon paste electrode; polyaniline; phenol; VOLTAMMETRY; SURFACE;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper deals with the application of polyaniline conducting polymer as a new sensor material for detection of phenol. The sensor is designed using bare carbon paste electrode (CPE), nonimprinted polymer-modified electrode (CPE/NIP) and imprinted polymer-modified electrode (CPE/MIP). These electrodes were prepared by electropolymerization of the monomer (aniline) in the presence of phenol as the template onto a carbon paste electrode. A CPE/MIP sensor which is modified with carbon paste electrode was able to detect the analyte more selectively. Several results regarding a decreasing in sensor activity were discussed. The ability of the electrodes to recognize the analyte was characterized using cyclic voltammetry (CV) in of 0.1M K-3[Fe(CN)(6)]/0.1M K-4[Fe(CN)(6)] acted as an electroactive specie at scan rate100 mV/s between potentials of -0.2 - 0.8 V by cyclic voltammetry under the optimal experimental condition.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 32 条
[1]  
Ali A., 2011, J KERBALA U, V9, P284
[2]  
[Anonymous], 2015, J. Agric. Chem. Environ, DOI [10.4236/jacen.2015.41002, DOI 10.4236/JACEN.2015.41002]
[3]  
Ansari R., 2006, E-Journal of Chemistry, V3, P202, DOI DOI 10.1155/2006/395391
[4]   Synchrotron-Based Infrared Microanalysis of Biological Redox Processes under Electrochemical Control [J].
Ash, Philip A. ;
Reeve, Holly A. ;
Quinson, Jonathan ;
Hidalgo, Ricardo ;
Zhu, Tianze ;
McPherson, Ian J. ;
Chung, Min-Wen ;
Healy, Adam J. ;
Nayak, Simantini ;
Lonsdale, Thomas H. ;
Wehbe, Katia ;
Kelley, Chris S. ;
Frogley, Mark D. ;
Cinque, Gianfelice ;
Vincent, Kylie A. .
ANALYTICAL CHEMISTRY, 2016, 88 (13) :6666-6671
[5]  
Aulia A. T., 2015, JURNAL PENELITIAN SA, V20, p53
[6]  
Bejan D, 1998, CROAT CHEM ACTA, V71, P745
[7]  
Binas Francis G., 2014, Acta Manilana, V62, P61, DOI 10.53603/actamanil.62.2014.esfw5424
[8]   Electrochemical study of 4-chloro-3-methylphenol on anodically pretreated boron-doped diamond electrode in the absence and presence of a cationic surfactant [J].
Brycht, Mariola ;
Lochynski, Pawel ;
Barek, Jiri ;
Skrzypek, Slawomira ;
Kuczewski, Krzysztof ;
Schwarzova-Peckova, Karolina .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 771 :1-9
[9]   Real-time electrochemical determination of phenolic compounds after benzene oxidation [J].
Cesarino, Ivana ;
Moraes, Fernando C. ;
Ferreira, Tanare C. R. ;
Lanza, Marcos R. V. ;
Machado, Sergio A. S. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 672 :34-39
[10]  