PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction

被引:189
作者
Samarin, Andrei [1 ]
Burger, Cyrill [1 ]
Wollenweber, Scott D. [2 ]
Crook, David W. [1 ]
Burger, Irene A. [1 ]
Schmid, Daniel T. [1 ]
von Schulthess, Gustav K. [1 ]
Kuhn, Felix P. [1 ]
机构
[1] Univ Zurich Hosp, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] GE Healthcare, Waukesha, WI USA
关键词
PET; MR; Attenuation correction; Bone segmentation; CT simulation; MR; SEGMENTATION; IMAGES; CT;
D O I
10.1007/s00259-012-2113-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Accurate attenuation correction (AC) is essential for quantitative analysis of PET tracer distribution. In MR, the lack of cortical bone signal makes bone segmentation difficult and may require implementation of special sequences. The purpose of this study was to evaluate the need for accurate bone segmentation in MR-based AC for whole-body PET/MR imaging. Methods In 22 patients undergoing sequential PET/CT and 3-T MR imaging, modified CT AC maps were produced by replacing pixels with values of > 100 HU, representing mostly bone structures, by pixels with a constant value of 36 HU corresponding to soft tissue, thereby simulating current MR-derived AC maps. A total of 141 FDG-positive osseous lesions and 50 soft-tissue lesions adjacent to bones were evaluated. The mean standardized uptake value (SUVmean) was measured in each lesion in PET images reconstructed once using the standard AC maps and once using the modified AC maps. Subsequently, the errors in lesion tracer uptake for the modified PET images were calculated using the standard PET image as a reference. Results Substitution of bone by soft tissue values in AC maps resulted in an underestimation of tracer uptake in osseous and soft tissue lesions adjacent to bones of 11.2 +/- 5.4 % (range 1.5-30.8 %) and 3.2 +/- 1.7 % (range 0.2-4 %), respectively. Analysis of the spine and pelvic osseous lesions revealed a substantial dependence of the error on lesion composition. For predominantly sclerotic spine lesions, the mean underestimation was 15.9 +/- 3.4 % (range 9.9-23.5 %) and for osteolytic spine lesions, 7.2 +/- 1.7 % (range 4.9-9.3 %), respectively. Conclusions CT data simulating treating bone as soft tissue as is currently done in MR maps for PET AC leads to a substantial underestimation of tracer uptake in bone lesions and depends on lesion composition, the largest error being seen in sclerotic lesions. Therefore, depiction of cortical bone and other calcified areas in MR AC maps is necessary for accurate quantification of tracer uptake values in PET/MR imaging.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 14 条
[1]   MR-based attenuation correction for torso-PET/MR imaging:: pitfalls in mapping MR to CT data [J].
Beyer, Thomas ;
Weigert, Markus ;
Quick, Harald H. ;
Pietrzyk, Uwe ;
Vogt, Florian ;
Palm, Christoph ;
Antoch, Gerald ;
Mueller, Stefan P. ;
Bockisch, Andreas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) :1142-1146
[2]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[3]   Repeatability of FDG quantification in tumor imaging: averaged SUVs are superior to SUVmax [J].
Burger, Irene A. ;
Huser, Dominic M. ;
Burger, Cyrill ;
von Schulthess, Gustav K. ;
Buck, Alfred .
NUCLEAR MEDICINE AND BIOLOGY, 2012, 39 (05) :666-670
[4]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[5]   Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions [J].
Eiber, Matthias ;
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Holzapfel, Konstantin ;
Pickhard, Anja ;
Loeffelbein, Dennys ;
Santi, Ivan ;
Rummeny, Ernst J. ;
Ziegler, Sibylle ;
Schwaiger, Markus ;
Nekolla, Stephan G. ;
Beer, Ambros J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (09) :1691-1701
[6]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883
[7]   MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods [J].
Hofmann, Matthias ;
Bezrukov, Ilja ;
Mantlik, Frederic ;
Aschoff, Philip ;
Steinke, Florian ;
Beyer, Thomas ;
Pichler, Bernd J. ;
Schoelkopf, Bernhard .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (09) :1392-1399
[8]   Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques [J].
Hofmann, Matthias ;
Pichler, Bernd ;
Schoelkopf, Bernhard ;
Beyer, Thomas .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 :93-104
[9]  
Keereman V, 2010, J NUCL MED, V51, P812, DOI 10.2967/jnumed.109.065425
[10]   Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data [J].
Martinez-Moeller, Axel ;
Souvatzoglou, Michael ;
Delso, Gaspar ;
Bundschuh, Ralph A. ;
Chefd'hotel, Christophe ;
Ziegler, Sibylle I. ;
Navab, Nassir ;
Schwaiger, Markus ;
Nekolla, Stephan G. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :520-526