Error in acetabular socket alignment due to the thick anterior pelvic soft tissues

被引:25
作者
Lee, Yeon Soo [1 ]
Yoon, Taek Rim [2 ]
机构
[1] GwangJu Inst Sci & Technol, Dept Informat & Mechatron Engn, Kwangju, South Korea
[2] Chonnam Natl Univ, Hwasun Hosp, Ctr Joint Dis, Jeonnam, South Korea
关键词
THA; navigation; anterior pelvic plane (APP); acetabular socket alignment; thick soft tissues; digitizing error;
D O I
10.1016/j.arth.2007.06.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to assess how much the digitizing error attributable to the thick soft tissues in the anterior pelvic area can affect the targeted acetabular socket alignment. The acetabular socket orientation angle was measured by using a synthetic pelvic model and an OrthoPilot total hip arthroplasty (Aesculap AG & Co KG, Tuttlingen, Germany) navigation system. The anterior pelvic plane was defined using 3 bony landmarks: the ipsilateral and contralateral anterior superior iliac spines (ASIS) and the center of the 2 pubic tubercles. The digitization error of I cut at the ipsilateral ASIS, contralateral ASIS, and the center of the two pubic tubercles resulted in 1.8 degrees, 4.4 degrees, and -6.8 degrees in anteversion, and 1.4 degrees, 0.2 degrees, and -0.2 degrees in abduction, respectively. The current navigation system based on the anterior pelvic plane may produce considerable error in guiding the acetabular socket anteversion for patients with thick soft tissue in the anterior pelvic area.
引用
收藏
页码:699 / 706
页数:8
相关论文
共 20 条
[1]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[2]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[4]   Computer assisted measurement of cup placement in total hip replacement [J].
Jaramaz, B ;
DiGioia, AM ;
Blackwell, M ;
Nikou, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) :70-81
[5]   Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[6]   Greater accuracy in positioning of the acetabular cup by using an image-free navigation system [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Baethis, H ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) :272-276
[7]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[8]   The effect of acetabular cup orientations on limiting hip rotation [J].
Kummer, FJ ;
Shah, S ;
Iyer, S ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :509-513
[9]  
LAMECKER H, 2004, SPIE MED IM 2004 S 1, P5370
[10]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220