Optimization of an air-liquid interface exposure system for assessing toxicity of airborne nanoparticles

被引:19
|
作者
Latvala, Siiri [1 ]
Hedberg, Jonas [2 ]
Moller, Lennart [3 ]
Wallinder, Inger Odnevall [2 ]
Karlsson, Hanna L. [4 ]
Elihn, Karine [1 ]
机构
[1] Stockholm Univ, Dept Environm Sci & Analyt Chem, Atmospher Sci Unit, SE-10691 Stockholm, Sweden
[2] KTH Royal Inst Technol, Sch Chem Sci & Engn, Div Surface & Corros Sci, SE-10044 Stockholm, Sweden
[3] Karolinska Inst, Dept Biosci & Nutr, Unit Analyt Toxicol, SE-14183 Huddinge, Sweden
[4] Karolinska Inst, Inst Environm Med, Div Biochem Toxicol, SE-17177 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
ALI; nanotoxicology; in vitro; silver; nanoparticles; electrostatic; A549; IN-VITRO; SILVER-NANOPARTICLES; CELL EXPOSURE; OCCUPATIONAL-EXPOSURE; LUNG-CELLS; SIZE; AGGLOMERATION; CYTOTOXICITY; PARTICLES; AEROSOLS;
D O I
10.1002/jat.3304
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The use of refined toxicological methods is currently needed for characterizing the risks of airborne nanoparticles (NPs) to human health. To mimic pulmonary exposure, we have developed an air-liquid interface (ALI) exposure system for direct deposition of airborne NPs on to lung cell cultures. Compared to traditional submerged systems, this allows more realistic exposure conditions for characterizing toxicological effects induced by airborne NPs. The purpose of this study was to investigate how the deposition of silver NPs (AgNPs) is affected by different conditions of the ALI system. Additionally, the viability and metabolic activity of A549 cells was studied following AgNP exposure. Particle deposition increased markedly with increasing aerosol flow rate and electrostatic field strength. The highest amount of deposited particles (2.2 g cm(-2)) at cell-free conditions following 2 h exposure was observed for the highest flow rate (390 ml min(-1)) and the strongest electrostatic field (2 kV). This was estimated corresponding to deposition efficiency of 94%. Cell viability was not affected after 2 h exposure to clean air in the ALI system. Cells exposed to AgNPs (0.45 and 0.74 g cm(-2)) showed significantly (P < 0.05) reduced metabolic activities (64 and 46%, respectively). Our study shows that the ALI exposure system can be used for generating conditions that were more realistic for in vitro exposures, which enables improved mechanistic and toxicological studies of NPs in contact with human lung cells.Copyright (c) 2016 The Authors Journal of Applied Toxicology Published by John Wiley & Sons Ltd.
引用
收藏
页码:1294 / 1301
页数:8
相关论文
共 50 条
  • [21] Particle deposition efficiency at air-liquid interface of a cell exposure chamber
    Fujitani, Yuji
    Sugaya, Yutaka
    Hashiguchi, Masanori
    Furuyama, Akiko
    Hirano, Seishiro
    Takami, Akinori
    JOURNAL OF AEROSOL SCIENCE, 2015, 81 : 90 - 99
  • [22] Simulations of submicron aerosol deposition at an air-liquid interface for in vitro toxicology
    Grabinski, Christin M.
    Hussain, Saber M.
    Sankaran, R. Mohan
    JOURNAL OF AEROSOL SCIENCE, 2015, 90 : 87 - 102
  • [23] Development of a Novel Shallow Liquid Interface Exposure System for MWCNT Toxicity Assessment
    Tien, Chi-Yu
    Li, Jui-Ping
    Han, Ding
    Li, Ziyi
    Fu, Pin-Kuei
    Chen, Jen-Kun
    Tsai, Chuen-Jinn
    CHEMICAL RESEARCH IN TOXICOLOGY, 2019, 32 (10) : 1925 - 1939
  • [24] Usefulness of toxicological validation of VOCs catalytic degradation by air-liquid interface exposure system
    Al Zallouha, Margueritta
    Landkocz, Yann
    Brunet, Julien
    Cousin, Renaud
    Genty, Eric
    Courcot, Dominique
    Siffert, Stephane
    Shirali, Pirouz
    Billet, Sylvain
    ENVIRONMENTAL RESEARCH, 2017, 152 : 328 - 335
  • [25] Dry Generation of CeO2 Nanoparticles and Deposition onto a Co-Culture of A549 and THP-1 Cells in Air-Liquid Interface-Dosimetry Considerations and Comparison to Submerged Exposure
    Cappellini, Francesca
    Di Bucchianico, Sebastiano
    Karri, Venkatanaidu
    Latvala, Siiri
    Malmlof, Maria
    Kippler, Maria
    Elihn, Karine
    Hedberg, Jonas
    Wallinder, Inger Odnevall
    Gerde, Per
    Karlsson, Hanna L.
    NANOMATERIALS, 2020, 10 (04)
  • [26] Evaluation of the toxicity of combustion smokes at the air-liquid interface: a comparison between two lung cell models and two exposure methods
    Ashrin, A.
    Anna, E.
    Peyret, E.
    Barbier, G.
    Floreani, Maxime
    Pointart, C.
    Medus, D.
    Fayet, G.
    Rotureau, P.
    Loret, T.
    Lacroix, G.
    ARCHIVES OF TOXICOLOGY, 2025, : 1471 - 1484
  • [27] Exposure of silver-nanoparticles and silver-ions to lung cells in vitro at the air-liquid interface
    Herzog, Fabian
    Clift, Martin J. D.
    Piccapietra, Flavio
    Behra, Renata
    Schmid, Otmar
    Petri-Fink, Alke
    Rothen-Rutishauser, Barbara
    PARTICLE AND FIBRE TOXICOLOGY, 2013, 10
  • [28] Aerosol generation and characterization of multi-walled carbon nanotubes exposed to cells cultured at the air-liquid interface
    Polk, William W.
    Sharma, Monita
    Sayes, Christie M.
    Hotchkiss, Jon A.
    Clippinger, Amy J.
    PARTICLE AND FIBRE TOXICOLOGY, 2016, 13
  • [29] Air-liquid interface exposure to aerosols of poorly soluble nanomaterials induces different biological activation levels compared to exposure to suspensions
    Loret, Thomas
    Peyret, Emmanuel
    Dubreuil, Marielle
    Aguerre-Chariol, Olivier
    Bressot, Christophe
    le Bihan, Olivier
    Amodeo, Tanguy
    Trouiller, Benedicte
    Braun, Anne
    Egles, Christophe
    Lacroix, Ghislaine
    PARTICLE AND FIBRE TOXICOLOGY, 2016, 13
  • [30] Assessing toxicity of amorphous nanoplastics in airway- and lung epithelial cells using air-liquid interface models
    Gosselink, I.F.
    van Schooten, F.J.
    Drittij, M.J.
    Höppener, E.M.
    Leonhardt, P.
    Moschini, E.
    Serchi, T.
    Gutleb, A.C.
    Kooter, I.M.
    Remels, A.H.
    Chemosphere, 2024, 368