Optimization of an air-liquid interface exposure system for assessing toxicity of airborne nanoparticles

被引:19
|
作者
Latvala, Siiri [1 ]
Hedberg, Jonas [2 ]
Moller, Lennart [3 ]
Wallinder, Inger Odnevall [2 ]
Karlsson, Hanna L. [4 ]
Elihn, Karine [1 ]
机构
[1] Stockholm Univ, Dept Environm Sci & Analyt Chem, Atmospher Sci Unit, SE-10691 Stockholm, Sweden
[2] KTH Royal Inst Technol, Sch Chem Sci & Engn, Div Surface & Corros Sci, SE-10044 Stockholm, Sweden
[3] Karolinska Inst, Dept Biosci & Nutr, Unit Analyt Toxicol, SE-14183 Huddinge, Sweden
[4] Karolinska Inst, Inst Environm Med, Div Biochem Toxicol, SE-17177 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
ALI; nanotoxicology; in vitro; silver; nanoparticles; electrostatic; A549; IN-VITRO; SILVER-NANOPARTICLES; CELL EXPOSURE; OCCUPATIONAL-EXPOSURE; LUNG-CELLS; SIZE; AGGLOMERATION; CYTOTOXICITY; PARTICLES; AEROSOLS;
D O I
10.1002/jat.3304
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The use of refined toxicological methods is currently needed for characterizing the risks of airborne nanoparticles (NPs) to human health. To mimic pulmonary exposure, we have developed an air-liquid interface (ALI) exposure system for direct deposition of airborne NPs on to lung cell cultures. Compared to traditional submerged systems, this allows more realistic exposure conditions for characterizing toxicological effects induced by airborne NPs. The purpose of this study was to investigate how the deposition of silver NPs (AgNPs) is affected by different conditions of the ALI system. Additionally, the viability and metabolic activity of A549 cells was studied following AgNP exposure. Particle deposition increased markedly with increasing aerosol flow rate and electrostatic field strength. The highest amount of deposited particles (2.2 g cm(-2)) at cell-free conditions following 2 h exposure was observed for the highest flow rate (390 ml min(-1)) and the strongest electrostatic field (2 kV). This was estimated corresponding to deposition efficiency of 94%. Cell viability was not affected after 2 h exposure to clean air in the ALI system. Cells exposed to AgNPs (0.45 and 0.74 g cm(-2)) showed significantly (P < 0.05) reduced metabolic activities (64 and 46%, respectively). Our study shows that the ALI exposure system can be used for generating conditions that were more realistic for in vitro exposures, which enables improved mechanistic and toxicological studies of NPs in contact with human lung cells.Copyright (c) 2016 The Authors Journal of Applied Toxicology Published by John Wiley & Sons Ltd.
引用
收藏
页码:1294 / 1301
页数:8
相关论文
共 50 条
  • [1] Toxicity of Silver Nanoparticles at the Air-Liquid Interface
    Holder, Amara L.
    Marr, Linsey C.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [2] A mobile air-liquid interface exposure system optimized for outdoor toxicity testing of aerosols
    Juarez-Facio, Ana Teresa
    Introna, Micol
    Gustavsson, Sven ake
    Attergren, Max
    Lindwall, Martin
    Olofsson, Ulf
    Steimer, Sarah Sulamith
    Elihn, Karine
    AEROSOL SCIENCE AND TECHNOLOGY, 2025, 59 (02) : 214 - 226
  • [3] Parametric Optimization of an Air-Liquid Interface System for Flow-Through Inhalation Exposure to Nanoparticles: Assessing Dosimetry and Intracellular Uptake of CeO2 Nanoparticles
    Leibrock, Lars B.
    Jungnickel, Harald
    Tentschert, Jutta
    Katz, Aaron
    Toman, Blaza
    Petersen, Elijah J.
    Bierkandt, Frank S.
    Singh, Ajay Vikram
    Laux, Peter
    Luch, Andreas
    NANOMATERIALS, 2020, 10 (12) : 1 - 25
  • [4] An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
    Braakhuis, Hedwig M.
    He, Ruiwen
    Vandebriel, Rob J.
    Gremmer, Eric R.
    Zwart, Edwin
    Vermeulen, Jolanda P.
    Fokkens, Paul
    Boere, John
    Gosens, Ilse
    Cassee, Flemming R.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [5] A new cell culture exposure system for studying the toxicity of volatile chemicals at the air-liquid interface
    Zavala, Jose
    Ledbetter, Allen D.
    Morgan, David S.
    Dailey, Lisa A.
    Puckett, Earl
    McCullough, Shaun D.
    Higuchi, Mark
    INHALATION TOXICOLOGY, 2018, 30 (4-5) : 169 - 177
  • [6] An exposure system for in vitro cell culture investigations of cigarette smoke toxicity at the air-liquid interface
    Adamson, J.
    Azzopardi, D.
    Gaca, M.
    TOXICOLOGY LETTERS, 2010, 196 : S135 - S135
  • [7] Establishing an air-liquid interface exposure system for exposure of lung cells to gases
    Guenette, Josee
    Breznan, Dalibor
    Thomson, Errol M.
    INHALATION TOXICOLOGY, 2022, 34 (3-4) : 80 - 89
  • [8] A LAB SCALE MEASUREMENT TECHNIQUE FOR THE AIR-LIQUID INTERFACE EXPOSURE OF HUMAN LUNG CELL CULTURES TOWARDS AIRBORNE NANOPARTICLES
    Muelhopt, Sonja
    Diabate, Silvia
    Schlager, Christoph
    Dilger, Marco
    Krebs, Tobias
    Paur, Hanns-Rudolf
    Weiss, Carsten
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : A30 - A30
  • [9] A dose-controlled system for air-liquid interface cell exposure and application to zinc oxide nanoparticles
    Anke Gabriele Lenz
    Erwin Karg
    Bernd Lentner
    Vlad Dittrich
    Christina Brandenberger
    Barbara Rothen-Rutishauser
    Holger Schulz
    George A Ferron
    Otmar Schmid
    Particle and Fibre Toxicology, 6
  • [10] Assessing toxicity of microplastics on airway epithelial cells using air-liquid interface models
    Gosselink, I. F.
    Remels, A. H.
    Kooter, I. M.
    Van De Steeg, E.
    Van Schooten, F. J.
    TOXICOLOGY LETTERS, 2022, 368 : S208 - S209