Withdrawal of shunt systems - clinical use of the programmable shunt system and its effect on hydrocephalus in children

被引:19
|
作者
Takahashi, Y [1 ]
机构
[1] Hokkaido Childrens Hosp & Med Ctr, Dept Pediat Neurosurg, Hokkaido, Japan
关键词
children; hydrocephalus; shunt; programmable valve; withdrawal of shunt; outcome;
D O I
10.1007/s003810000424
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objects: The most important function of the programmable valve (PV) is to limit the shunt-dependent flow of the cerebrospinal fluid by upgrading valve pressure. This activates the regular circulation of cerebrospinal fluid, which may make successful removal of the shunt possible once sufficient cerebral development has been achieved. The purpose of this paper is to indicate the possibility of shunt removal using the programmable Medos and Sophy valves (one programmable Sophy valve was specially designed for this situation). Methods: Prior to regular use of the PV, removal of existing shunt systems was attempted in 57 children, since some systems malfunctioned and others had abdominal tubes that were meanwhile too short as the children had grown as they became older. Shunt removal was successfully achieved in only 18 patients (32%). However, in patients in whom PV valves were used, shunt removal was successful in 68 out of 114 patients (57%). This shows that the success rate of shunt removal becomes significantly higher when PV valves are used. The 68 cases in which PV valves were used and shunt removal was successful were divided into three groups: A, B, and C. In group A (36 cases, 53%), the Medos valve was used for the initial PV shunt implantation and the pressure was gradually increased up to 200 mmH(2)O. The shunt systems were then withdrawn. Group B (29 cases, 43%) includes patients who experienced both the minor symptoms and ventricular enlargement attributable to increased valve pressure. The pressure was gradually upgraded by pumping several times and was maintained at close to 200 mmH(2)O. After 6-24 months' observation shunt removal was performed, and in 21 out of 29 cases the outcome was good. However, the remaining 8 patients (12%) still had symptoms and required shunt reinsertion. The specially designed Sophy valves were then used, which allowed the pressure to be set at above 200 mmH(2)O. The pressure was increased by degrees up to 400 mmH(2)O and kept at the same level for 6-24 months. The shunt systems were then removed successfully. Although a high pressure setting was required over a sustained period, a total of 29 patients (43%) were able to have their shunts removed. In group C (3 cases, 4%), which included patients with aqueduct stenosis. the pressure was raised and thus allowed ventricle enlargement. Third ventriculostomy was performed under neuroendoscopy with the shunt pressure maintained at a high level. Shunt systems were removed successfully. Conclusions: This study showed that it is possible to remove the shunt systems in 50% or more of pediatric hydrocephalus cases in which PV valves are used. This is achieved through careful control of the valve pressure. Close observation is essential during the period when the PV pressure is maintained at a high level, as well as 6-12 months after shunt removal.
引用
收藏
页码:472 / 477
页数:6
相关论文
共 50 条
  • [1] Withdrawal of the shunt. Main purpose of clinically using the programmable shunt system and its effectiveness in pediatric hydrocephalus
    Takahashi, Y
    11TH EUROPEAN CONGRESS OF NEUROSURGERY: EUROPEAN ASSOCIATION OF NEUROSURGICAL SOCIETIES (EANS), 1999, : 655 - 660
  • [2] Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus
    Zemack, G
    Bellner, J
    Siesjö, P
    Strömblad, LG
    Romner, B
    JOURNAL OF NEUROSURGERY, 2003, 98 (03) : 471 - 476
  • [3] Calgary Shunt Protocol, an adaptation of the Hydrocephalus Clinical Research Network shunt protocol, reduces shunt infections in children
    Yang, Michael M. H.
    Hader, Lwalter
    Bullivant, Kelly
    Brindle, Mary
    Riva-Cambrin, Jay
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2019, 23 (05) : 559 - 567
  • [4] Shunt systems in the treatment of hydrocephalus
    Mikolajczyk-Wieczorek, Wanda
    Nowoslawska, Emilia
    AKTUALNOSCI NEUROLOGICZNE, 2009, 9 (01): : 26 - 36
  • [5] Shunt complications in children with myelomeningocele: effect of timing of shunt placement Clinical article
    Radmanesh, Farid
    Nejat, Farideh
    El Khashab, Mostafa
    Ghodsi, Syed Mohammad
    Ardebili, Hasan Eftekhar
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2009, 3 (06) : 516 - 520
  • [6] Visual field constriction in children with shunt-treated hydrocephalus
    Rudolph, Diana
    Sterker, Ina
    Graefe, Gerd
    Till, Holger
    Ulrich, Anett
    Geyer, Christian
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2010, 6 (05) : 481 - 485
  • [7] Programmable shunt valves for the treatment of hydrocephalus: A systematic review
    Xu, H.
    Wang, Z. X.
    Liu, F.
    Tan, G. W.
    Zhu, H. W.
    Chen, D. H.
    EUROPEAN JOURNAL OF PAEDIATRIC NEUROLOGY, 2013, 17 (05) : 454 - 461
  • [8] A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus
    Pollack, IF
    Albright, AL
    Adelson, PD
    NEUROSURGERY, 1999, 45 (06) : 1399 - 1408
  • [9] Clinical diagnosis of ventriculoperitoneal shunt failure among children with hydrocephalus
    Piatt, Joseph H., Jr.
    Garton, Hugh J. L.
    PEDIATRIC EMERGENCY CARE, 2008, 24 (04) : 201 - 210
  • [10] CSF shunt removal in children with hydrocephalus
    Iannelli, A
    Rea, G
    Di Rocco, C
    ACTA NEUROCHIRURGICA, 2005, 147 (05) : 503 - 507