Usage of CLPU curve to deal with the cold load pickup problem

被引:11
|
作者
Mirza, OH
机构
[1] System Protection and Technical Field Services, Puget Sound Power and Light Co., Bellevue, WA
关键词
cold load pickup; step-by-step restoration; protective relays; pickup of relays and reclosers; time overcurrent characteristic (TOC) curves; power circuit breaker (PCB);
D O I
10.1109/61.584335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Restoration of load after an extended power outage, whether planned or unplanned, raises various practical concerns. Previous studies have shown the cold load condition lasts between 2 to 60 minutes, or longer, depending on the duration of the outage, type of load, and the local weather. The theory presented in this paper is applicable to an microprocessor based overcurrent protective devices used at the distribution level. The example used in the paper is to provide a possible method to handle cold load pickup problems at line reclosers installed an the distribution system. The new approach is to control the pickup of the phase element of the recloser as a function of time. The pickup of the recloser starts at a preset value after an extended outage and slowly decreases and returns to the normal pickup in a predetermined manner. The relationship of the pickup level and time could he determined by considering the maximum cold load current and its gradual decay with time.
引用
收藏
页码:660 / 667
页数:8
相关论文
共 50 条
  • [1] COLD LOAD PICKUP
    MCDONALD, JE
    BRUNING, AM
    MAHIEU, WR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (04): : 1384 - 1386
  • [2] Cold Load Pickup Issues
    Friend, Fred
    2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, : 176 - 187
  • [3] COLD LOAD PICKUP ON THE DISTRIBUTION SYSTEM.
    Anon
    1600,
  • [4] PHYSICALLY BASED MODELING OF COLD LOAD PICKUP
    IHARA, S
    SCHWEPPE, FC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (09): : 4142 - 4150
  • [5] THE EFFECTS OF COLD LOAD PICKUP ON DISTRIBUTION TRANSFORMERS
    WILDE, RL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (05): : 2433 - 2437
  • [6] Distribution system feeder cold load pickup model
    Leou, RC
    Gaing, ZL
    Lu, CN
    Chang, BS
    Cheng, CL
    ELECTRIC POWER SYSTEMS RESEARCH, 1996, 36 (03) : 163 - 168
  • [7] Distribution system design optimization for cold load pickup
    Wakileh, JJ
    Pahwa, A
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1996, 11 (04) : 1879 - 1884
  • [8] EFFECTS OF COLD LOAD PICKUP AT THE DISTRIBUTION SUBSTATION TRANSFORMER
    WILDE, RL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (03): : 704 - 710
  • [9] An overview of cold load pickup issues in distribution systems
    Kumar, V
    Gupta, I
    Gupta, HO
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2006, 34 (06) : 639 - 651
  • [10] EFFECTS OF COLD LOAD PICKUP ON DISTRIBUTION TRANSFORMERS.
    Wilde, R.L.
    Engineering News-Record, 1981,