Cobalt blue light unit filter - A smartphone attachment for blue light photography

被引:7
作者
Puthalath, Athul S. [1 ]
Gupta, Neeti [1 ]
Samanta, Ramanuj [1 ]
Singh, Anupam [1 ]
Kumawat, Devesh [1 ]
Mittal, Sanjeev K. [1 ]
机构
[1] All India Inst Med Sci, Dept Ophthalmol, Rishikesh 249203, Uttarakhand, India
关键词
Blue light; cornea; imaging; smartphone; telemedicine;
D O I
10.4103/ijo.IJO_3697_20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to carry out blue light photography of fluorescein-stained corneas using a novel smartphone attachment. Methods: A smartphone attachment known as the cobalt blue light unit (C-BLU) was developed. It can filter out all wavelengths of light except the blue light emerging from the flashlight of a smartphone. A pilot study was carried out wherein the images captured with the C-BLU system were compared with slit-lamp photographs of the same patients. This setup was then used to photo document fluorescein-stained corneas in various clinical settings assembled at point-of-care. Results: Many pathologies of the fluorescein-stained cornea were captured using the C-BLU filter. It was used effectively in various settings (remote eye camps, intensive care units (ICU), pediatric group, corneal trauma triaging, etc.). C-BLU was assembled and used by optometrists and ophthalmology residents. The images captured were used for documenting, assisting in the treatment, and also for telecommunication of the patients' findings. Conclusion: C-BLU is a low-cost pocket-size filter which is easy to use with a modern smartphone without any technical expertise needed to obtain a clear image of fluorescein-stained pathological corneas.
引用
收藏
页码:2841 / 2843
页数:3
相关论文
共 13 条
[1]  
Akkara J. D., 2019, Kerala Journal of Ophthalmology, V31, P64, DOI DOI 10.4103/KJO.KJO_24_19
[2]   Commentary: The glued intraocular lens smartphone microscope [J].
Akkara, John Davis ;
Kuriakose, Anju .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) :1692-1692
[3]  
[Anonymous], Hand-Held Portable Slit Lamp from Reichert Review of Ophthalmology
[4]   iPhones for eye surgeons [J].
Bastawrous, A. ;
Cheeseman, R. C. ;
Kumar, A. .
EYE, 2012, 26 (03) :343-354
[5]   THE USE OF SODIUM FLUORESCEIN IN ASSESSING THE RATE OF HEALING IN CORNEAL ULCERS [J].
CAMPBELL, FW ;
BOYD, TAS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1950, 34 (09) :545-549
[6]  
Chakrabarti R, 2012, J Mob Technol Med, V1, P1
[7]   Anterior segment photography with intraocular lens [J].
Chandrakanth, Prithvi ;
Nallamuthu, P. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) :1690-1691
[8]   Smartphones in ophthalmology [J].
Chhablani, Jay ;
Kaja, Simon ;
Shah, Vinay A. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (02) :127-131
[9]  
HOLLAND MC, 1964, JAMA-J AM MED ASSOC, V188, P81
[10]  
Kim J, 2000, Curr Opin Ophthalmol, V11, P241, DOI 10.1097/00055735-200008000-00005