Embol-X Intraaortic Filter and Transaortic Approach for Improved Cerebral Protection in Transcatheter Aortic Valve Implantation

被引:24
作者
Etienne, Pierre-Yves [1 ]
Papadatos, Spiridon
Pieters, Denis
El Khoury, Elie
Alexis, Frederic
Price, Joel
Glineur, David
机构
[1] Clin St Luc, Dept Cardiac Surg, B-5004 Bouge, Belgium
关键词
STENOSIS; SURGERY;
D O I
10.1016/j.athoracsur.2011.05.109
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Techniques for transcatheter aortic valve implantation involve manipulation of the native aortic valve and the aortic arch. As a result, excellent technical outcomes of this technique remain counterbalanced by a level of neurologic complications that remain unacceptably high. We present here a report of a new potential combined approach to reduce periprocedural neurologic events. After a 6-cm J-shaped upper-mini-sternotomy, 26-mm Sapien valve (Edwards Lifesciences, Irvine, CA) was deployed through a transaortic approach. In addition, the Embol-X device (Edwards Lifescience) was directly inserted in the distal ascending aorta was deployed during all the procedure. Postoperative evolution was clinically uneventful. Postoperative magnetic resonance imaging revealed no new ischemic lesions in this first patient. (Ann Thorac Surg 2011;92:e95-6) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:E95 / E96
页数:2
相关论文
共 8 条
[1]   Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve [J].
Astarci, Parla ;
Glineur, David ;
Kefer, Joelle ;
D'Hoore, William ;
Renkin, Jean ;
Vanoverschelde, Jean-Louis ;
El Khoury, Gebrine ;
Grandin, Cecile .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (02) :475-479
[2]   Transcatheter Aortic Valve Implantation with "No Touch" of the Aortic Arch for the Treatment of Severe Aortic Stenosis Associated with Complex Aortic Atherosclerosis [J].
Bagur, Rodrigo ;
Rodes-Cabau, Josep ;
Doyle, Daniel ;
De Larochelliere, Robert ;
Villeneuve, Jacques ;
Bertrand, Olivier F. ;
Dumont, Eric .
JOURNAL OF CARDIAC SURGERY, 2010, 25 (05) :501-503
[3]   Emboli capture using the Embol-X IntraAortic filter in cardiac surgery: A multicentered randomized trial of 1,289 patients [J].
Banbury, MK ;
Kouchoukos, NT ;
Allen, KB ;
Slaughter, MS ;
Weissman, NJ ;
Berry, GJ ;
Horvath, KA .
ANNALS OF THORACIC SURGERY, 2003, 76 (02) :508-515
[4]   Transaortic Transcatheter Aortic Valve Implantation With the Edwards Sapien Valve: Feasibility, Technical Considerations, and Clinical Advantages [J].
Etienne, Pierre-Yves ;
Papadatos, Spiridon ;
El Khoury, Elie ;
Pieters, Denis ;
Price, Joel ;
Glineur, David .
ANNALS OF THORACIC SURGERY, 2011, 92 (02) :746-748
[5]   Ischemic cerebral lesions after carotid surgery and carotid stenting [J].
Lacroix, V. ;
Hammer, F. ;
Astarci, P. ;
Duprez, T. ;
Grandin, C. ;
Cosnard, G. ;
Peeters, A. ;
Verhelst, R. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2007, 33 (04) :430-435
[6]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[7]   An Embolic Deflection Device for Aortic Valve Interventions [J].
Nietlispach, Fabian ;
Wijesinghe, Namal ;
Gurvitch, Ronen ;
Tay, Edgar ;
Carpenter, Jeffrey P. ;
Burns, Carol ;
Wood, David A. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) :1133-1138
[8]  