Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach

被引:412
作者
Cannesson, Maxime [1 ]
Le Manach, Yannick [2 ,3 ]
Hofer, Christoph K. [4 ]
Goarin, Jean Pierre [5 ]
Lehot, Jean-Jacques [6 ]
Vallet, Benoit [7 ]
Tavernier, Benoit [7 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Anesthesiol & Perioperat Care, Irvine, CA 92717 USA
[2] CHU Pitie Salpetriere, Dept Anesthesiol & Crit Care Med, Paris, France
[3] Univ Oxford, Wolfson Coll, Ctr Stat Med, Oxford, England
[4] Triemli City Hosp, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
[5] CHU Pitie Salpetriere, Dept Anesthesiol & Intens Care Med, Paris, France
[6] Hop Louis Pradel, Dept Anesthesiol & Crit Care, Lyon, France
[7] CHU Lille, Dept Anesthesiol & Crit Care Med, F-59037 Lille, France
关键词
STROKE VOLUME VARIATION; MECHANICALLY VENTILATED PATIENTS; RISK SURGICAL-PATIENTS; CARDIAC-OUTPUT; RESPIRATORY VARIATIONS; SEPTIC PATIENTS; ABILITY; MANAGEMENT; MONITORS; CONTOUR;
D O I
10.1097/ALN.0b013e318225b80a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach. Methods: The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated. Results: The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10(-5)). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits. Conclusion: Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 31 条
  • [11] Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery
    Derichard, A.
    Robin, E.
    Tavernier, B.
    Costecalde, M.
    Fleyfel, M.
    Onimus, J.
    Lebuffe, G.
    Chambon, J. -P.
    Vallet, B.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) : 678 - 684
  • [12] THE INADEQUACY OF BINARY MODELS FOR THE CLINICAL REALITY OF 3-ZONE DIAGNOSTIC DECISIONS
    FEINSTEIN, AR
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1990, 43 (01) : 109 - 113
  • [13] Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    Feissel, M
    Michard, F
    Mangin, I
    Ruyer, O
    Faller, JP
    Teboul, JL
    [J]. CHEST, 2001, 119 (03) : 867 - 873
  • [14] Is It a Bird? Is It a Plane? The Role of Patient Monitors in Medical Decision Making
    Feldman, Jeffrey M.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 108 (03) : 707 - 710
  • [15] A unification of models for meta-analysis of diagnostic accuracy studies
    Harbord, Roger M.
    Deeks, Jonathan J.
    Egger, Matthias
    Whiting, Penny
    Sterne, Jonathan A. C.
    [J]. BIOSTATISTICS, 2007, 8 (02) : 239 - 251
  • [16] Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    Hofer, Christoph K.
    Senn, Alban
    Weibel, Luc
    Zollinger, Andreas
    [J]. CRITICAL CARE, 2008, 12 (03):
  • [17] Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    Hofer, CK
    Müller, SM
    Furrer, L
    Klaghofer, R
    Genoni, M
    Zollinger, A
    [J]. CHEST, 2005, 128 (02) : 848 - 854
  • [18] Empirical evidence of design-related bias in studies of diagnostic tests
    Lijmer, JG
    Mol, BW
    Heisterkamp, S
    Bonsel, GJ
    Prins, MH
    van der Meulen, JHP
    Bossuyt, PMM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (11): : 1061 - 1066
  • [19] Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial
    Lopes, Marcel R.
    Oliveira, Marcos A.
    Pereira, Vanessa Oliveira S.
    Lemos, Ivaneide Paula B.
    Auler, Jose Otavio C., Jr.
    Michard, Frederick
    [J]. CRITICAL CARE, 2007, 11 (05):
  • [20] Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    Marik, Paul E.
    Baram, Michael
    Vahid, Bobbak
    [J]. CHEST, 2008, 134 (01) : 172 - 178