Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach

被引:412
作者
Cannesson, Maxime [1 ]
Le Manach, Yannick [2 ,3 ]
Hofer, Christoph K. [4 ]
Goarin, Jean Pierre [5 ]
Lehot, Jean-Jacques [6 ]
Vallet, Benoit [7 ]
Tavernier, Benoit [7 ]
机构
[1] Univ Calif Irvine, Sch Med, Dept Anesthesiol & Perioperat Care, Irvine, CA 92717 USA
[2] CHU Pitie Salpetriere, Dept Anesthesiol & Crit Care Med, Paris, France
[3] Univ Oxford, Wolfson Coll, Ctr Stat Med, Oxford, England
[4] Triemli City Hosp, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
[5] CHU Pitie Salpetriere, Dept Anesthesiol & Intens Care Med, Paris, France
[6] Hop Louis Pradel, Dept Anesthesiol & Crit Care, Lyon, France
[7] CHU Lille, Dept Anesthesiol & Crit Care Med, F-59037 Lille, France
关键词
STROKE VOLUME VARIATION; MECHANICALLY VENTILATED PATIENTS; RISK SURGICAL-PATIENTS; CARDIAC-OUTPUT; RESPIRATORY VARIATIONS; SEPTIC PATIENTS; ABILITY; MANAGEMENT; MONITORS; CONTOUR;
D O I
10.1097/ALN.0b013e318225b80a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach. Methods: The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated. Results: The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10(-5)). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits. Conclusion: Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 31 条
  • [1] Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    Benes, Jan
    Chytra, Ivan
    Altmann, Pavel
    Hluchy, Marek
    Kasal, Eduard
    Svitak, Roman
    Pradl, Richard
    Stepan, Martin
    [J]. CRITICAL CARE, 2010, 14 (03):
  • [2] Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    Biais, M.
    Nouette-Gaulain, K.
    Cottenceau, V.
    Revel, P.
    Sztark, F.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 761 - 768
  • [3] Influence of systolic-pressure-variation-guided intraoperative fluid management on organ function and oxygen transport
    Buettner, M.
    Schummer, W.
    Huettemann, E.
    Schenke, S.
    van Hout, N.
    Sakka, S. G.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) : 194 - 199
  • [4] The ability of a novel algorithm for automatic estimation of the respiratory variations, in arterial pulse pressure to monitor fluid responsiveness in the operating room
    Cannesson, Maxime
    Slieker, Juliette
    Desebbe, Olivier
    Bauer, Christian
    Chiari, Pascal
    Henaine, Roland
    Lehot, Jean-Jacques
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (04) : 1195 - 1200
  • [5] Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room
    Cannesson, Maxime
    Attof, Yassin
    Rosamel, Pascal
    Desebbe, Olivier
    Joseph, Pierre
    Metton, Olivier
    Bastien, Olivier
    Lehot, Jean-Jacques
    [J]. ANESTHESIOLOGY, 2007, 106 (06) : 1105 - 1111
  • [6] Arterial Pressure Variation and Goal-Directed Fluid Therapy
    Cannesson, Maxime
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (03) : 487 - 497
  • [7] The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients
    Cannesson, Maxime
    Musard, Henri
    Desebbe, Olivier
    Boucau, Cecile
    Simon, Remi
    Henaine, Roland
    Lehot, Jean-Jacques
    [J]. ANESTHESIA AND ANALGESIA, 2009, 108 (02) : 513 - 517
  • [8] A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
    Critchley, Lester A.
    Lee, Anna
    Ho, Anthony M. -H.
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (05) : 1180 - 1192
  • [9] Systematic reviews in health care - Systematic reviews of evaluations of diagnostic and screening
    Deeks, JJ
    [J]. BRITISH MEDICAL JOURNAL, 2001, 323 (7305): : 157 - 162
  • [10] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845