Direct electrochemistry and electrocatalysis of hemoglobin immobilized into poly (lactic-co-glycolic acid)/room temperature ionic liquid composite film

被引:21
作者
Zhang, Yao [1 ]
Sun, Xiumei [1 ]
Jia, Nengqin [1 ]
机构
[1] Shanghai Normal Univ, Coll Life & Environm Sci, Dept Chem, Shanghai 200234, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 157卷 / 02期
关键词
Poly(lactic-co-glycolic acid); Hemoglobin; 1-Butyl-3-methylimidazolium tetrafluoroborate; Direct electrochemistry; Electrocatalysis; DIRECT ELECTRON-TRANSFER; GLASSY-CARBON ELECTRODE; HYDROGEN-PEROXIDE; GOLD NANOPARTICLES; PASTE ELECTRODE; BIOELECTROCHEMISTRY; BIOCOMPATIBILITY; MYOGLOBIN;
D O I
10.1016/j.snb.2011.05.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A promising material of poly(lactic-co-glycolic acid) (PLGA) and, room temperature ionic liquid (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]BF4) was firstly used as an immobilization matrix to entrap proteins and its bioelectrochemical properties were studied. Direct electrochemistry and electrocatalytic behaviors of hemoglobin (Hb) entrapped in the PLGA/ILs composite film on the surface of glass carbon electrode were investigated. UV-vis spectroscopy, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the composite film. The obtained results demonstrated that the Hb molecule in the film kept its native structure and showed its good electrochemical behavior. A pair of well-defined redox peaks of Hb was obtained at the Hb/PLGA/ILs composite film-modified GC electrode through direct electron transfer between the protein and the underlying electrode. The proposed biosensor showed good reproducibility and high sensitivity to H2O2 with the detection limit of 2.37 x 10(-7) M (S/N = 3). In the range of 5.0 x 10(-6) to 8.05 x 10(-3) M, the catalytic reduction current of H2O2 was proportional to its concentration. The apparent Michaelis-Menten constant of Hb in the PLGA/ILs composite film was estimated to be 0.069 mM, showing its high affinity. (C) Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 532
页数:6
相关论文
共 36 条
[21]   Direct electrochemistry and electrocatalysis of heme-proteins immobilized in porous carbon nanofiber/room-temperature ionic liquid composite film [J].
Sheng, Qing-Lin ;
Zheng, Jian-Bin ;
Shang-Guan, Xiao-Dong ;
Lin, Wang-Hua ;
Li, Yuan-Yao ;
Liu, Rui-Xiao .
ELECTROCHIMICA ACTA, 2010, 55 (09) :3185-3191
[22]   Electrochemistry and electrocatalysis of hemoglobin on multi-walled carbon nanotubes modified carbon ionic liquid electrode with hydrophilic EMIMBF4 as modifier [J].
Sun, Wei ;
Li, Xiaoqing ;
Wang, Yan ;
Zhao, Ruijun ;
Jiao, Kui .
ELECTROCHIMICA ACTA, 2009, 54 (17) :4141-4148
[23]   BIORESORBABILITY AND BIOCOMPATIBILITY OF ALIPHATIC POLYESTERS [J].
VERT, M ;
LI, SM ;
SPENLEHAUER, G ;
GUERIN, P .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (06) :432-446
[24]   Adsorption and direct electron transfer from hemoglobin into a three-dimensionally ordered. macroporous gold film [J].
Wang, CH ;
Yang, C ;
Song, YY ;
Gao, W ;
Xia, XH .
ADVANCED FUNCTIONAL MATERIALS, 2005, 15 (08) :1267-1275
[25]   Probing traces of hydrogen peroxide by use of a biosensor based on mediator-free DNA and horseradish peroxidase immobilized on silver nanoparticles [J].
Wang, Fuchuang ;
Yuan, Ruo ;
Chai, Yaqin ;
Tang, Dianping .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) :709-717
[26]   Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film [J].
Wang, QL ;
Lu, GX ;
Yang, BJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :50-57
[27]   Direct electrochemistry and electrocatalysis of hemoglobin immobilized on carbon paste electrode by silica sol-gel film [J].
Wang, QL ;
Lu, GX ;
Yang, BJ .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1269-1275
[28]   Effects of hydrophilic room-temperature ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate on direct electrochemistry and bioelectrocatalysis of heme proteins entrapped in agarose hydrogel films [J].
Wang, Sheng-Fu ;
Chen, Ting ;
Zhang, Zhi-Ling ;
Pang, Dai-Wen ;
Wong, Kwok-Yin .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (07) :1709-1714
[29]   Direct electrochemistry and biocatalytic activity of hemoglobin entrapped into gellan gum and room temperature ionic liquid composite system [J].
Wen, Yanli ;
Yang, Xudong ;
Hu, Guohua ;
Chen, Shouhui ;
Jia, Nengqin .
ELECTROCHIMICA ACTA, 2008, 54 (02) :744-748
[30]   REVERSIBLE ELECTRODE-REACTION OF CYTOCHROME-C [J].
YEH, P ;
KUWANA, T .
CHEMISTRY LETTERS, 1977, (10) :1145-1148