Biodegradable Piezoelectric Transducer for Powering Transient Implants

被引:25
作者
Selvarajan, Sophia [1 ,2 ]
Kim, Albert [3 ]
Song, Seung Hyun [1 ]
机构
[1] Sookmyung Womens Univ, Dept Elect Engn, Seoul 04310, South Korea
[2] Sungkyunkwan Univ SKKU, IQB, Dept Biophys, Suwon 16419, South Korea
[3] Temple Univ, Dept Elect & Comp Engn, Philadelphia, PA 19122 USA
关键词
Implants; Transient analysis; Acoustics; Nanoparticles; Piezoelectric transducers; Sonar equipment; Biodegradable materials; implants; piezoelectric transducers; wireless power transmission; SILK FIBROIN; ELECTRONICS;
D O I
10.1109/ACCESS.2020.2985993
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Transient implantable medical devices based on biodegradable electronics can be used for diagnostic and therapeutic purposes for a desired duration and undergo biodegradation, unlike their conventional counterparts. However, powering transient implants through biodegradable power sources remains under-explored. Here, we report biodegradable piezoelectric transducer fabricated using 0-3 composite film made of barium titanate nanoparticles and poly (L-lactic-co-glycolic) acid polymer (BT-PLGA). The proposed BT-PLGA can be utilized in two different powering schemes; ultrasonic powering and energy harvesting from low frequency acoustic waves. We demonstrated that the power density of the BT-PLGA transducer can reach up to 10 mW/cm(2) in ultrasonic powering. The energy harvesting from low frequency acoustic waves could also readily generate sufficient power for small electronics. The fabricated transducers underwent complete biodegradation in physiological conditions within 100 days. The development of the biodegradable piezoelectric transducer potentially provides a reliable power source for transient implants, especially for deeply seated bioelectronics. The output performance, biocompatibility, and tunable biodegradation of BT-PLGA transducer demonstrate its potential as a biodegradable power source for transient implantable devices.
引用
收藏
页码:68219 / 68225
页数:7
相关论文
共 41 条
[1]   A review of acoustic power transfer for biomedical implants [J].
Basaeri, Hamid ;
Christensen, David B. ;
Roundy, Shad .
SMART MATERIALS AND STRUCTURES, 2016, 25 (12)
[2]   Batteries used to power implantable biomedical devices [J].
Bock, David C. ;
Marschilok, Amy C. ;
Takeuchi, Kenneth J. ;
Takeuchi, Esther S. .
ELECTROCHIMICA ACTA, 2012, 84 :155-164
[3]   Biodegradable Electronic Systems in 3D, Heterogeneously Integrated Formats [J].
Chang, Jan-Kai ;
Chang, Hui-Ping ;
Guo, Qinglei ;
Koo, Jahyun ;
Wu, Chih-I ;
Rogers, John A. .
ADVANCED MATERIALS, 2018, 30 (11)
[4]   Biodegradable Piezoelectric Force Sensor [J].
Curry, Eli J. ;
Ke, Kai ;
Chorsi, Meysam T. ;
Wrobel, Kinga S. ;
Miller, Albert N., III ;
Patel, Avi ;
Kim, Insoo ;
Feng, Jianlin ;
Yue, Lixia ;
Wu, Qian ;
Kuo, Chia-Ling ;
Lo, Kevin W. -H. ;
Laurencin, Cato T. ;
Ilies, Horea ;
Purohit, Prashant K. ;
Nguyen, Thanh D. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2018, 115 (05) :909-914
[5]  
Denisov Alexey, 2010, 2010 International Conference on Body Sensor Networks (BSN), P84, DOI 10.1109/BSN.2010.27
[6]   Polarization rotation mechanism for ultrahigh electromechanical response in single-crystal piezoelectrics [J].
Fu, HX ;
Cohen, RE .
NATURE, 2000, 403 (6767) :281-283
[7]   Transient Electronics: Materials and Devices [J].
Fu, Kun Kelvin ;
Wang, Zhengyang ;
Dai, Jiaqi ;
Carter, Marcus ;
Hu, Liangbing .
CHEMISTRY OF MATERIALS, 2016, 28 (11) :3527-3539
[8]   Moisture-triggered physically transient electronics [J].
Gao, Yang ;
Zhang, Ying ;
Wang, Xu ;
Sim, Kyoseung ;
Liu, Jingshen ;
Chen, Ji ;
Feng, Xue ;
Xu, Hangxun ;
Yu, Cunjiang .
SCIENCE ADVANCES, 2017, 3 (09)
[9]   Energy harvesting for the implantable biomedical devices: issues and challenges [J].
Hannan, Mahammad A. ;
Mutashar, Saad ;
Samad, Salina A. ;
Hussain, Aini .
BIOMEDICAL ENGINEERING ONLINE, 2014, 13
[10]   In-situ Raman spectroscopy of BaTiO3 particles for tetragonal-cubic transformation [J].
Hayashi, Hiromichi ;
Nakamura, Takashi ;
Ebina, Takeo .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2013, 74 (07) :957-962