Implementation and control of asymmetric thermal environment in two-dimensional rectangular enclosure

被引:2
作者
Shen, L [1 ]
Deng, QH [1 ]
机构
[1] Cent S Univ, Sch Energy & Power Engn, Changsha 410083, Peoples R China
来源
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY | 2005年 / 12卷 / Suppl 1期
关键词
adiabatic partition; natural convection; asymmetric heating condition;
D O I
10.1007/s11771-005-0411-4
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Laminar natural convection in an enclosure divided by an adiabatic partition on its bottom with two unequal discrete heat sources was investigated numerically. The effect of the partition on the flow structure and heat transfer characteristics in enclosure under asymmetric heating condition was studied. The parameters are the Rayleigh number (1 X 10(4)<= Ra <= 1 X 10(6)) and the height of partition (0 <= h/H <= 0.70). The streamlines are produced for various Rayleigh numbers. The results reflected by variations of the average Nusselt number in terms of the height of partition illustrates the convection heat transfer in the enclosure. The role of the partition is to weaken or cut off the heat removal rate from the strong heat source to the weak heat source. It is analyzed that the optimum height of the partition to break the linkage between the strong and weak heat source increases with increasing Rayleigh number.
引用
收藏
页码:262 / 267
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 1980, SERIES COMPUTATIONAL, DOI [DOI 10.1201/9781482234213, 10.1201/9781482234213]
[2]   Natural convection in enclosures with partial partitions [J].
Bilgen, E .
RENEWABLE ENERGY, 2002, 26 (02) :257-270
[3]   Simulation of a cavity insulated by a vertical single band cold air curtain [J].
Chen, YG ;
Yuan, XL .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (11-12) :1745-1756
[4]   A numerical study of the unsteady flow and heat transfer in a transitional confined slot jet impinging on an isothermal surface [J].
Chiriac, VA ;
Ortega, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (06) :1237-1248
[5]   Distribution of heat sources in vertical open channels with natural convection [J].
da Silva, AK ;
Lorenzini, G ;
Bejan, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (08) :1462-1469
[6]   Optimal distribution of discrete heat sources on a wall with natural convection [J].
da Silva, AK ;
Lorente, S ;
Bejan, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) :203-214
[7]   Special treatment of pressure correction based on continuity conservation in a pressure-based algorithm [J].
Deng, QH ;
Tang, GF .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2002, 42 (01) :73-92
[8]  
Deng Qihong, 2003, MODELING CHARACTERIS
[10]   NATURAL-CONVECTION IN A PARTIALLY DIVIDED ENCLOSURE [J].
LIN, NN ;
BEJAN, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (12) :1867-1878