Adaptation of capillary isoelectric focusing to microchannels on a glass chip

被引:140
作者
Hofmann, O [1 ]
Che, DP [1 ]
Cruickshank, KA [1 ]
Müller, UR [1 ]
机构
[1] Vysis Inc, Downers Grove, IL 60515 USA
关键词
D O I
10.1021/ac9806660
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As a first step toward adaptation of capillary isoelectric focusing (cIEF) to microchannels on a glass chip, we have compared the three most common mobilization methods: chemical, hydrodynamic, and electroosmotic now (EOF)-driven mobilization. Using a commercial cIEF apparatus with coated or uncoated fused-silica capillaries, both chemical and hydrodynamic mobilization gave superior separation efficiency and reproducibility. However, EOF-driven mobilization, which occurs simultaneously with focusing, proved most suitable for miniaturization because of high speed, EOF compatibility and low instrumentation requirements. When this method was tested in a 200-mu m-wide, 10-mu m-deep, and 7-cm-long channel etched into planar glass, a mixture of Cy5-labeled peptides could be focused in less than 30 s, with plate heights of 0.4 mu m (410 plates/s) upon optimization. For a total analysis time of less than 5 min, we estimate a maximum peak capacity of approximately 30-40, interestingly, the order of migration was found to be reversed compared to capillary-based focusing.
引用
收藏
页码:678 / 686
页数:9
相关论文
共 25 条
[1]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[2]   ELECTROPHORETIC SEPARATIONS OF PROTEINS IN CAPILLARIES WITH HYDROLYTICALLY STABLE SURFACE-STRUCTURES [J].
COBB, KA ;
DOLNIK, V ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2478-2483
[3]   Simultaneous multiple analyte detection using fluorescent peptides and capillary isoelectric focusing [J].
Cruickshank, KA ;
Olvera, J ;
Muller, UR .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :41-47
[4]  
Effenhauser CS, 1998, TOP CURR CHEM, V194, P51
[5]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[6]  
Giddings J.C., 1991, Unified separation science
[7]  
GUO YJ, 1982, J CHROMATOGR, V234, P459
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[10]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270