Validation of computational fluid dynamics simulation methods for venous pulsatile tinnitus

被引:1
作者
Hsieh, Yue-Lin [1 ,2 ]
Wang, Dan [1 ,2 ]
Xu, Xiaobing [1 ,2 ,3 ]
Yu, Dengtao
Wu, Yongzhen [1 ,2 ]
Ping, Guo [1 ,2 ]
Wang, Wuqing [1 ,2 ]
机构
[1] Fudan Univ, Eye Ear Nose & Throat Hosp, Dept Otol & Skull Base Surg, Shanghai 200031, Peoples R China
[2] NHC Key Lab Hearing Med, Shanghai 200031, Peoples R China
[3] Shanghai Elect Gas Turbine Co Ltd, Inst Gas Turbine, 333 Jiangchuan Rd, Shanghai 201100, Peoples R China
来源
MODERN PHYSICS LETTERS B | 2021年 / 35卷 / 36期
基金
中国国家自然科学基金;
关键词
Pulsatile tinnitus; numerical simulation; computational fluid dynamics; turbulent; sonification; FLOW; COMPRESSION; STENOSIS;
D O I
10.1142/S0217984921505229
中图分类号
O59 [应用物理学];
学科分类号
摘要
There has been a growing interest in the investigation of hydroacoustic characteristics of pulsatile tinnitus (PT). However, a proper technique for computational fluid dynamics (CFD) simulation has yet to be discussed. The primary goal of this paper was to investigate the intrasinus hydroacoustic characteristics of PT at the transverse-sigmoid junction (TSJ) using Doppler ultrasound and examine the validity of CFD techniques in simultaneity. The preoperative and intraoperative Doppler ultrasound were performed on a patient with PT at upper jugular vein and TSJ, respectively. Canonical CFD techniques were applied to solve the computational transverse-sigmoid sinus flow domain and compared with the Doppler's measurements. In addition, the spectro-temporal analysis was performed for the sonification of PT. PT was associated with the recirculating flows at the TSJ according to ultrasonographic detection. This pathogenic region was characterized by a sudden deceleration of flow velocity and inverse increase of flow static pressure, which large eddy simulation (LES) resulted in the smallest 7.4% velocity difference compared to the measured Doppler data, albeit with little differences compared to other solvers. Therefore, based on this case study, the transient LES approach is an optimal CFD method for the computational simulation of the complex hemodynamics at the TSJ. Further numerical studies with large case series are warrranted.
引用
收藏
页数:13
相关论文
共 28 条
[21]   Large-Eddy simulation of pulsatile blood flow [J].
Paul, Manosh C. ;
Molla, Md. Mamun ;
Roditi, Giles .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :153-159
[22]   Torrents of torment: turbulence as a mechanism of pulsatile tinnitus secondary to venous stenosis revealed by high-fidelity computational fluid dynamics [J].
Pereira, Vitor M. ;
Cancelliere, Nicole Mariantonia ;
Najafi, Mehdi ;
MacDonald, Dan ;
Natarajan, Thangam ;
Radovanovic, Ivan ;
Krings, Timo ;
Rutka, John ;
Nicholson, Patrick ;
Steinman, David A. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (08) :732-737
[23]   Comparison between magnetic resonance phase contrast imaging and transcranial Doppler ultrasound with regard to blood flow velocity in intracranial arteries:: Work in progress [J].
Seitz, J ;
Strotzer, M ;
Schlaier, J ;
Nitz, WR ;
Völk, M ;
Feuerbach, S .
JOURNAL OF NEUROIMAGING, 2001, 11 (02) :121-128
[24]   Pulsatile tinnitus: contemporary assessment and management [J].
Sismanis, Aristides .
CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2011, 19 (05) :348-357
[25]   Sigmoid sinus cortical plate dehiscence induces pulsatile tinnitus through amplifying sigmoid sinus venous sound [J].
Tian, Shan ;
Wang, Lizhen ;
Yang, Jiemeng ;
Mao, Rui ;
Liu, Zhaohui ;
Fan, Yubo .
JOURNAL OF BIOMECHANICS, 2017, 52 :68-73
[26]  
Wilcox D.C., 2006, Turbulence Modelling for CFD
[27]  
Yoganathan AP, 2005, ANN BIOMED ENG, V33, P1689, DOI 10.1007/s10439-005-8759-y
[28]   CT venography correlate of transverse sinus stenosis and venous transstenotic pressure gradient in unilateral pulsatile tinnitus patients with sigmoid sinus wall anomalies [J].
Zhao, Pengfei ;
Ding, Heyu ;
Lv, Han ;
Li, Xiaoshuai ;
Qiu, Xiaoyu ;
Zeng, Rong ;
Wang, Guopeng ;
Wei, Jian ;
Jin, Long ;
Yang, Zhenghan ;
Gong, Shusheng ;
Wang, Zhenchang .
EUROPEAN RADIOLOGY, 2021, 31 (05) :2896-2902