Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection

被引:55
|
作者
Muhammad-Tahir, Z [1 ]
Alocilja, EC [1 ]
机构
[1] Michigan State Univ, Dept Biosyst Engn, E Lansing, MI 48824 USA
关键词
conductimetric; electrochemical immunoassay; immunosensor; polyaniline;
D O I
10.1109/JSEN.2003.815782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the safety in the food supply becomes critical, the demand for a rapid, low-volume, and sensitive microbial detection device has dramatically increased. A biosensor based on an electrochemical sandwich immunoassay using polyaniline has been developed for detecting foodborne pathogens, such as Escherichia coli (E. coli) O157:H7. The biosensor is comprised of two types of proteins: capture protein and reporter protein. The capture protein is immobilized on a pad between two electrodes, while the reporter protein is attached to conductive polymers. After adding the sample, the target protein binds to the reporter protein and forms a sandwich complex with the capture protein. The conductive polymer that is attached to the reporter protein serves as a messenger, reporting the amount of target protein captured in the form of an electrical signal. The architecture of the biosensor utilizes lateral flow format, which allows the liquid sample to move from one pad to another by capillary action. Experiments to evaluate the best construction materials, the optimal polyaniline and antibody concentrations, and the distance between electrodes are highlighted in this paper. Results show that the biosensor could detect approximately 7.8 x 10(1) colony forming unit per mililiter of E. coli O157:H7 in 10 min.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 50 条
  • [1] DEVELOPMENT OF A DISPOSABLE IMPEDANCE BIOSENSOR AND ITS APPLICATION FOR DETERMINATION OF ESCHERICHIA COLI O157:H7
    Wang, Y. X.
    Ye, Z. Z.
    Ying, Y. B.
    TRANSACTIONS OF THE ASABE, 2014, 57 (02) : 585 - 592
  • [2] Escherichia coli O157:H7
    Weir, E
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2000, 163 (02) : 205 - 205
  • [3] Escherichia coli O157:H7
    Hartigan, PJ
    IRISH VETERINARY JOURNAL, 1997, 50 (02) : 91 - +
  • [4] Escherichia coli O157:H7
    Riemann, HP
    Cliver, DO
    VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1998, 14 (01) : 41 - +
  • [5] Escherichia coli O157:H7
    Mead, PS
    Griffin, PM
    LANCET, 1998, 352 (9135): : 1207 - 1212
  • [6] Escherichia coli O157:H7
    Tarr, PI
    Neill, MA
    GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2001, 30 (03) : 735 - +
  • [7] Escherichia coli O157:H7
    OLoughin, E
    LANCET, 1997, 349 (9064): : 1553 - 1553
  • [8] Detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor
    Fratamico, PM
    Strobaugh, TP
    Medina, MB
    Gehring, AG
    BIOTECHNOLOGY TECHNIQUES, 1998, 12 (07) : 571 - 576
  • [9] Label-free amperometric biosensor for Escherichia coli O157:H7 detection
    Dhull, Nidhi
    Kaur, Gurpreet
    Jain, Prateek
    Mishra, Priyanka
    Singh, Divya
    Ganju, Lilly
    Gupta, Vinay
    Tomar, Monika
    APPLIED SURFACE SCIENCE, 2019, 495
  • [10] Rapid detection of Escherichia coli O157:H7 using tunneling magnetoresistance biosensor
    Wu, Yuanzhao
    Liu, Yiwei
    Zhan, Qingfeng
    Liu, J. Ping
    Li, Run-Wei
    AIP ADVANCES, 2017, 7 (05):