Rayleigh Mixture Model for Plaque Characterization in Intravascular Ultrasound

被引:56
作者
Seabra, Jose C. [1 ]
Ciompi, Francesco [2 ]
Pujol, Oriol [2 ,3 ]
Mauri, Josepa [4 ]
Radeva, Petia [2 ,3 ]
Sanches, Joao [1 ]
机构
[1] Univ Tecn Lisboa, Inst Super Tecn, Inst Syst & Robot, P-1049001 Lisbon, Portugal
[2] Univ Autonoma Barcelona, Comp Vis Ctr, Barcelona 08193, Spain
[3] Univ Barcelona, Dept Matemat Aplicada & Anal, E-08007 Barcelona, Spain
[4] Univ Hosp Germans Trias & Pujol, Badalona 08916, Spain
关键词
Echomorphology; intravascular ultrasound (IVUS); plaque characterization; Rayleigh mixture model (RMM); vulnerable plaque; HOMODYNED K-DISTRIBUTION; TISSUE CHARACTERIZATION; SPECKLE; STATISTICS; IMAGES;
D O I
10.1109/TBME.2011.2106498
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vulnerable plaques are the major cause of carotid and coronary vascular problems, such as heart attack or stroke. A correct modeling of plaque echomorphology and composition can help the identification of such lesions. The Rayleigh distribution is widely used to describe (nearly) homogeneous areas in ultrasound images. Since plaques may contain tissues with heterogeneous regions, more complex distributions depending on multiple parameters are usually needed, such as Rice, K or Nakagami distributions. In such cases, the problem formulation becomes more complex, and the optimization procedure to estimate the plaque echomorphology is more difficult. Here, we propose to model the tissue echomorphology by means of a mixture of Rayleigh distributions, known as the Rayleigh mixture model (RMM). The problem formulation is still simple, but its ability to describe complex textural patterns is very powerful. In this paper, we present a method for the automatic estimation of the RMM mixture parameters by means of the expectation maximization algorithm, which aims at characterizing tissue echomorphology in ultrasound (US). The performance of the proposed model is evaluated with a database of in vitro intravascular US cases. We show that the mixture coefficients and Rayleigh parameters explicitly derived from the mixture model are able to accurately describe different plaque types and to significantly improve the characterization performance of an already existing methodology.
引用
收藏
页码:1314 / 1324
页数:11
相关论文
共 23 条
[1]  
[Anonymous], 2014, Diagnostic Ultrasound Imaging
[2]   Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - A statistical approach [J].
Brusseau, E ;
de Korte, CL ;
Mastik, F ;
Schaar, J ;
van der Steen, AFW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :554-566
[3]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[4]  
CABALLERO KL, P IEEE ENG MED BIOL, P2167
[5]   Fusing in-vitro and in-vivo intravascular ultrasound data for plaque characterization [J].
Ciompi, Francesco ;
Pujol, Oriol ;
Gatta, Carlo ;
Rodriguez-Leor, Oriol ;
Mauri-Ferre, Josepa ;
Radeva, Petia .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (07) :763-779
[6]  
Cover T.M., 2006, ELEMENTS INFORM THEO, V2nd ed
[7]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[8]  
Demsar J, 2006, J MACH LEARN RES, V7, P1
[9]  
Dietterich T. G., 1995, Journal of Artificial Intelligence Research, V2, P263
[10]   ULTRASOUND ECHO ENVELOPE ANALYSIS USING A HOMODYNED K-DISTRIBUTION SIGNAL MODEL [J].
DUTT, V ;
GREENLEAF, JF .
ULTRASONIC IMAGING, 1994, 16 (04) :265-287