Exergoenvironmental and exergoeconomic analyses of a vertical type ground source heat pump integrated wall cooling system

被引:18
作者
Akbulut, Ugur [1 ]
Utlu, Zafer [2 ]
Kincay, Olcay [3 ]
机构
[1] Recep Tayyip Erdogam Univ, Dept Mech Engn, TR-52349 Rize, Turkey
[2] Istanbul Aydin Univ, Dept Mech Engn, TR-34455 Istanbul, Turkey
[3] Yildiz Tech Univ, Dept Mech Engn, TR-34349 Istanbul, Turkey
关键词
Cooling; Energy; Exergy; Heat pump; Exergoenvironmental; Exergoeconomic; Wall cooling; EXERGY ANALYSIS; ENERGY; UNCERTAINTY; PERFORMANCE; IMPACT; FLOOR; ROOM;
D O I
10.1016/j.applthermaleng.2016.03.178
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, exergoenvironmental, and exergoeconomic analyses of wall cooling systems fed by a vertical type of ground source heat pump integrated wall cooling system for cooling were examined experimentally and theoretically in Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University. The examination includes energy, exergy, exergoenvironmental and exergoeconomic analyses, between the dates of 1 July and 30 September 2013. The main aim of this objective is to minimize energy usage in Residential Sector as low as possible. Therefore, a particular system working with low temperature regime was chosen. According to the outcomes; energy and exergy efficiency of all the system have been found as 74.85% and 29.90%. Part-based environmental factor values are calculated. The compressor and underground heat exchanger have the highest values calculated as 0.040 mPts/s, 0.026 mPts/s respectively. The exergoenvironmental impact values of all system are detected as 42.60%. On the other hand; the exergoeconomic factor values of all system are calculated as 77.68%. The value of exergoeconomic factor changes depending on some particular components: accumulator tank, undersoil heat exchanger, evaporator and condenser calculated respectively as 69.43%, 62.59%, 62.53% and 29.15%. As a result; it is found that in order to determine economic and environmental impacts of irreversibilities occurring in the system and its components, economic and environmental analyses of thermal system as well as wall cooling systems, should be done based on exergy concept. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:904 / 921
页数:18
相关论文
共 32 条
[1]   Determination of the Effect of Wall Heating Systems on Convective Heat Transfer Coefficient in Buildings [J].
Acikgoz, Ozgen ;
Kincay, Olcay ;
Utlu, Zafer .
MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 :1630-+
[2]   Analysis of a wall cooling system using a heat pump [J].
Akbulut, Ugur ;
Kincay, Olcay ;
Utlu, Zafer .
RENEWABLE ENERGY, 2016, 85 :540-553
[3]   A new house wall system for residential buildings [J].
Aldawi, Fayez ;
Alam, Firoz ;
Date, Abhijit ;
Alghamdi, Mohammed ;
Aldhawi, Fahad .
ENERGY AND BUILDINGS, 2013, 67 :403-418
[4]  
[Anonymous], 2006, ISO ISO 140402006 EN, P20
[5]  
[Anonymous], 2006, ISO 14040 2006 ENV M
[6]  
[Anonymous], ASME J HEAT TRANSFER
[7]   Thermal performance analysis of a solar energy sourced latent heat storage [J].
Aydin, Devrim ;
Utlu, Zafer ;
Kincay, Olcay .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 50 :1213-1225
[8]   Comprehensive exergy analysis of a ground-source heat pump system for both building heating and cooling modes [J].
Bi, Yuehong ;
Wang, Xinhong ;
Liu, Yun ;
Zhang, Hua ;
Chen, Lingen .
APPLIED ENERGY, 2009, 86 (12) :2560-2565
[9]   Modelling and validation of a gas engine heat pump working with R410A for cooling applications [J].
Elgendy, E. ;
Schmidt, J. ;
Khalil, A. ;
Fatouh, M. .
APPLIED ENERGY, 2011, 88 (12) :4980-4988
[10]   Exergoenvironmental analysis of hybrid electric vehicle thermal management systems [J].
Hamut, H. S. ;
Dincer, I. ;
Naterer, G. F. .
JOURNAL OF CLEANER PRODUCTION, 2014, 67 :187-196