Indoor air quality in Portuguese schools: levels and sources of pollutants

被引:106
作者
Madureira, J. [1 ]
Paciencia, I. [1 ]
Pereira, C. [2 ]
Teixeira, J. P. [2 ,3 ]
Fernandes, E. de O. [1 ]
机构
[1] Inst Mech Engn & Ind Management, Rua Dr Roberto Frias, P-4200465 Oporto, Portugal
[2] Natl Inst Hlth, Environm Hlth Dept, Oporto, Portugal
[3] Univ Porto, Publ Hlth Inst, Oporto, Portugal
关键词
Indoor air quality; Schools; Bioaerosol; Ventilation; Particulate matter; Indoor sources; PARTICULATE MATTER; ELEMENTARY-SCHOOLS; CLEANING PRODUCTS; OUTDOOR AIR; POLLUTION; CHILDREN; VENTILATION; CLASSROOMS; EXPOSURE; HEALTH;
D O I
10.1111/ina.12237
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5, PM10, bacteria and fungi, carbon dioxide (CO2), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5g/m(3)) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools.
引用
收藏
页码:526 / 537
页数:12
相关论文
共 55 条
[1]   Children exposure to atmospheric particles in indoor of Lisbon primary schools [J].
Almeida, Susana Marta ;
Canha, Nuno ;
Silva, Ana ;
Freitas, Maria do Carmo ;
Pegas, Priscilla ;
Alves, Celia ;
Evtyugina, Margarita ;
Pio, Casimiro Adriao .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (40) :7594-7599
[2]   INDOOR AIR QUALITY AND SOURCES IN SCHOOLS AND RELATED HEALTH EFFECTS [J].
Annesi-Maesano, Isabella ;
Baiz, Nour ;
Banerjee, Soutrik ;
Rudnai, Peter ;
Rive, Solenne .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2013, 16 (08) :491-550
[3]   Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study [J].
Annesi-Maesano, Isabella ;
Hulin, Marion ;
Lavaud, Francois ;
Raherison, Chantal ;
Kopferschmitt, Christine ;
de Blay, Frederic ;
Charpin, Denis Andre ;
Denis, Caillaud .
THORAX, 2012, 67 (08) :682-688
[4]  
[Anonymous], 1998, NIOSH Manual of Analytical Methods
[5]  
[Anonymous], 2011, 1600062011 ISO
[6]  
ANSI/ASHRAE, 2001, 622001 ANSIASHRAE
[7]  
*ASTM INT, 2002, D624598 ASTM INT
[8]  
ASTM International, 2006, Standard e741-00-standard test method for determining air change in a single zone by means of a tracer gas dilution
[9]   Monitoring of volatile organic compounds in non-residential indoor environments [J].
Bruno, P. ;
Caselli, M. ;
de Gennaro, G. ;
Iacobellis, S. ;
Tutino, M. .
INDOOR AIR, 2008, 18 (03) :250-256
[10]  
European Standards, 2000, 13098 CSN EN