First US Experience Using the Pipeline Flex Embolization Device with Shield Technology for Treatment of Intracranial Aneurysms

被引:17
作者
Cappuzzo, Justin M. [1 ,6 ]
Monteiro, Andre [1 ,6 ]
Taylor, Maritza N. [4 ]
Waqas, Muhammad [1 ,6 ]
Baig, Ammad A. [1 ,6 ]
Almayman, Faisal [1 ,6 ]
Davies, Jason M. [1 ,2 ,5 ,6 ,7 ]
Snyder, Kenneth, V [1 ,5 ,6 ,7 ]
Siddiqui, Adnan H. [1 ,2 ,3 ,5 ,6 ]
Levy, Elad, I [1 ,3 ,5 ,6 ,7 ]
机构
[1] Jacobs Sch Med & Biomed Sci, Dept Neurosurg, Buffalo, NY 14260 USA
[2] Jacobs Sch Med & Biomed Sci, Dept Bioinformat, Buffalo, NY USA
[3] Jacobs Sch Med & Biomed Sci, Dept Radiol, Buffalo, NY 14260 USA
[4] Univ Buffalo, Jacobs Sch Med, Buffalo, NY USA
[5] Univ Buffalo, Canon Stroke & Vasc Res Ctr, Buffalo, NY 14260 USA
[6] Gates Vasc Inst Kaleida Hlth, Dept Neurosurg, Buffalo, NY 14203 USA
[7] Jacobs Inst, Buffalo, NY 14203 USA
基金
美国国家卫生研究院;
关键词
Aneurysm; Flow diversion; Pipeline embolization device; Shield technology; FLOW DIVERTORS; DIVERSION; OUTCOMES;
D O I
10.1016/j.wneu.2021.12.031
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The Pipeline Flex Embolization Device with Shield technology (PED-Shield [Medtronic, Dublin, Ireland]) is a third-generation flow diverter. Surface modification of the mesh with phosphorylcholine covalently bound to the metal struts aims to reduce thrombogenicity. In the present study, we report the results from the first U.S. series of patients with intracranial aneurysms treated with the PED-Shield and a comprehensive systematic literature review. METHODS: We retrospectively collected the patient demographics, aneurysm characteristics, procedural details, and periprocedural complications from our prospectively maintained endovascular database (April 2021 to July 2021). Our literature review encompassed 3 databases (PubMed, Embase, and MEDLINE). RESULTS: Ten patients with 11 anterior circulation unruptured wide-necked aneurysms (10 saccular, 1 fusiform) were included. The average patient age was 64.7 years (range, 45-86 years), and 9 were women. One device demonstrated insufficient distal opening. No other technical issues or intraprocedural complications had occurred. After the procedure, 1 patient had developed a groin hematoma and 1 had experienced a small intracranial hemorrhage, with no clinical repercussions. All patients were discharged with dual-antiplatelet therapy. In the review, we identified 15 studies. Most had been conducted in Europe and South America and 3 were U.S. case reports of compassionate use of the device. CONCLUSIONS: In our initial periprocedural experience with the PED-Shield for intracranial aneurysm treatment, the device demonstrated an excellent performance and no major complications. Further studies are required to evaluate the long-term follow-up results and the safety of different antiplatelet regimens.
引用
收藏
页码:E184 / E191
页数:8
相关论文
共 33 条
[1]   Endoluminal flow diverters in the treatment of sidewall and bifurcation aneurysm: A systematic review and meta-analysis of complications and angiographic outcomes [J].
Abbasi, Mehdi ;
Savasatano, Luis E. ;
Brinjikji, Waleed ;
Kallmes, Kevin M. ;
Mikoff, Nick ;
Reierson, Natalie ;
Abdelmegeed, Mohamed ;
Pederson, John ;
Warren, Beth ;
Touchette, Jillienne C. ;
Khan, Sarah ;
Kamrowski, Shelby ;
Barrett, Averi ;
Kallmes, David F. ;
Kadirvel, Ramanathan .
INTERVENTIONAL NEURORADIOLOGY, 2022, 28 (02) :229-239
[2]   Outcome Study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU) [J].
Atasoy, D. ;
Kandasamy, N. ;
Hart, J. ;
Lynch, J. ;
Yang, S. -H. ;
Walsh, D. ;
Tolias, C. ;
Booth, T. C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (12) :2094-2101
[3]   Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial [J].
Becske, Tibor ;
Brinjikji, Waleed ;
Potts, Matthew B. ;
Kallmes, David F. ;
Shapiro, Maksim ;
Moran, Christopher J. ;
Levy, Elad I. ;
McDougall, Cameron G. ;
Szikora, Istvan ;
Lanzino, Giuseppe ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Siddiqui, Adnan H. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Saatci, Isil ;
Cekirge, Saruhan H. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Nelson, Peter K. .
NEUROSURGERY, 2017, 80 (01) :40-48
[4]   Retrospective Analysis of Delayed Intraparenchymal Hemorrhage after Flow-Diverter Treatment: Presentation of a Retrospective Multicenter Trial [J].
Benaissa, A. ;
Tomas, C. ;
Clarencon, F. ;
Sourour, N. ;
Herbreteau, D. ;
Spelle, L. ;
Gallas, S. ;
Januel, A. -C. ;
Gaultier, A. L. ;
Pierot, L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) :475-480
[5]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[6]   The low-profile Neuroform Atlas stent in the treatment of wide-necked intracranial aneurysms - immediate and midterm results: An Italian multicenter registry [J].
Caragliano, Antonio A. ;
Papa, Rosario ;
Pitrone, Antonio ;
Limbucci, Nicola ;
Nappini, Sergio ;
Ruggiero, Maria ;
Visconti, Emiliano ;
Alexandre, Andrea ;
Menozzi, Roberto ;
Lauretti, Dario ;
Cavasin, Nicola ;
Alibrandi, Angela ;
Tessitore, Agostino ;
Longo, Marcello ;
Vinci, Sergio L. .
JOURNAL OF NEURORADIOLOGY, 2020, 47 (06) :421-427
[7]   Use of aspirin as sole oral antiplatelet therapy in acute flow diversion for ruptured dissecting aneurysms [J].
Chiu, Albert Ho Yuen ;
Ramesh, Rajalakshmi ;
Wenderoth, Jason ;
Davies, Mark ;
Cheung, Andrew .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (05) :E18-+
[8]  
Girdhar Gaurav, 2019, eNeurologicalSci, V14, P77, DOI 10.1016/j.ensci.2019.01.004
[9]   Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model [J].
Girdhar, Gaurav ;
Andersen, Arielle ;
Pangerl, Elizabeth ;
Jahanbekam, Reza ;
Ubl, Samantha ;
Nguyen, Kevin ;
Wainwright, John ;
Wolf, Michael F. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2018, 106 (12) :3195-3202
[10]   In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices [J].
Girdhar, Gaurav ;
Li, Junwei ;
Kostousov, Larisa ;
Wainwright, John ;
Chandler, Wayne L. .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2015, 40 (04) :437-443