MEMS-based Coulter counter for cell counting and sizing using multiple electrodes

被引:13
作者
Wu, Y. [1 ]
Benson, J. D. [2 ]
Critser, J. K. [3 ]
Almasri, M. [1 ]
机构
[1] Univ Missouri, Dept Elect & Comp Engn, Coll Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Coll Arts & Sci, Dept Math, Columbia, MO 65211 USA
[3] Univ Missouri, Coll Vet Med, Comparat Med Ctr, Columbia, MO 65211 USA
关键词
PERMEABILITY;
D O I
10.1088/0960-1317/20/8/085035
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel MEMS-based Coulter counter is designed, fabricated and tested in this paper. The Coulter counter is used for detection and monitoring the impedance changes of cells as a function of time after they are mixed with different experimental extracellular environments. The device consists of a multilayer of the SU-8 microchannel which is divided into a passive mixing region, a focusing region using negative dielectrophoretic forces and a measuring region by multiple electroplated vertical electrode pairs. The devices were tested with both fluidic and electrical functionality using dyed fluids, microbeads with different dimensions suspended in saline water and fibroblast cells in anisosmotic phosphate buffered saline. The results are presented and discussed. The device ultimately aims at testing time-sensitive cell characteristics after exposure to different extracellular media with enhanced sensitivity.
引用
收藏
页数:8
相关论文
共 38 条
[1]   The good, the bad, and the tiny: a review of microflow cytometry [J].
Ateya, Daniel A. ;
Erickson, Jeffrey S. ;
Howell, Peter B., Jr. ;
Hilliard, Lisa R. ;
Golden, Joel P. ;
Ligler, Frances S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1485-1498
[2]   Electric impedance spectroscopy using microchannels with integrated metal electrodes [J].
Ayliffe, HE ;
Frazier, AB ;
Rabbitt, RD .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1999, 8 (01) :50-57
[3]   Continuous particle separation by size via AC-dielectrophoresis using a lab-on-a-chip device with 3-D electrodes [J].
Cetin, Barbaros ;
Kang, Yuejun ;
Wu, Zhemin ;
Li, Dongqing .
ELECTROPHORESIS, 2009, 30 (05) :766-772
[4]   Optical microflow cytometer for particle counting, sizing and fluorescence detection [J].
Chen, Han-Taw ;
Wang, Yao-Nan .
MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (04) :529-537
[5]  
Coulter W. H., 1953, US Patent, Patent No. 2656508
[6]  
COULTER WH, 1970, Patent No. 3502974
[7]   RAPID WHOLE-BLOOD PLATELET COUNTING USING AN ELECTRONIC PARTICLE COUNTER [J].
EASTHAM, RD .
JOURNAL OF CLINICAL PATHOLOGY, 1963, 16 (02) :168-&
[8]   MEASUREMENT OF MEAN CELL-VOLUME USING ELECTRONIC PARTICLE COUNTERS [J].
ENGLAND, JM ;
DOWN, MC .
BRITISH JOURNAL OF HAEMATOLOGY, 1976, 32 (03) :403-409
[9]   Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing [J].
Gawad, S ;
Schild, L ;
Renaud, P .
LAB ON A CHIP, 2001, 1 (01) :76-82
[10]   High throughput particle analysis: Combining dielectrophoretic particle focussing with confocal optical detection [J].
Holmes, D ;
Morgan, H ;
Green, NG .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1621-1630