The genesis stent: A new low-profile stent for use in infants, children, and adults with congenital heart disease

被引:37
作者
Forbes, TJ
Rodriguez-Cruz, E
Amin, Z
Benson, LN
Fagan, TE
Hellenbrand, WE
Latson, LA
Moore, P
Mullins, CE
Vincent, JA
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Dept Pediat, Div Cardiol, Detroit, MI 48201 USA
[2] Creighton Univ, Univ Nebraska, Med Ctr, Div Pediat Cardiol, Omaha, NE USA
[3] Hosp Sick Children, Toronto, ON M5G 1X8, Canada
[4] Univ Iowa Hosp & Clin, Div Pediat Cardiol, Iowa City, IA 52242 USA
[5] Cleveland Clin, Div Pediat Cardiol, Cleveland, OH 44106 USA
[6] Childrens Hosp, Div Cardiol, New York, NY USA
[7] Univ Calif San Francisco, Div Pediat Cardiol, San Francisco, CA 94143 USA
[8] Texas Childrens Hosp, Dept Cardiol, Houston, TX 77030 USA
关键词
stent; infants; congenital; stenosis; children;
D O I
10.1002/ccd.10547
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Placement of intravascular stents that can reach adult size in infants and smaller children has been limited by the large profile and poor flexibility of currently available stents. In vitro and in vivo testing of the Genesis stent was performed to evaluate crimpability, predeployment flexibility, and radial strength. Comparisons were made to the Palmaz iliac and IntraStent (IS) LD stents. Nine physicians placed 30 Genesis stents in swine pulmonary and systemic arteries to evaluate stent deliverability/crimpability. Two swine were recovered and underwent a second catheterization 8 weeks later, where the stents (n = 8) were reexpanded to maximal size. Angiographic and intravascular ultrasound (IVUS) assessments were performed. In vitro testing revealed the Genesis stent to have superior crimpability, flexibility, and comparable radial strength to the Palmaz iliac stent, and superior crimpability and radial strength and comparable flexibility to the IS LD series. During in vivo testing, the physicians graded the Genesis stent superior to the Palmaz stent regarding crimpability and deliverability, and superior to the IS LD stent in regard to crimpability, and comparable to or superior in deliverability. In the chronic animals, the Genesis stent was expanded up to maximal diameter 8 weeks following implantation. Angiographic and IVUS revealed no fractures no in-stent restenosis. The Genesis stent can be easily delivered through smaller sheaths, which will facilitate their use in infants and smaller children with vascular stenosis. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:406 / 414
页数:9
相关论文
共 14 条
[1]   Use of balloon-expandable stents for coarctation of the aorta: Initial results and intermediate-term follow-up [J].
Ebeid, MR ;
Prieto, LR ;
Latson, LA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1847-1852
[2]   Endovascular stents for coarctation of the aorta: Initial results and intermediate-term follow-up [J].
Hamdan, MA ;
Maheshwari, S ;
Fahey, JT ;
Hellenbrand, WE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) :1518-1523
[3]   REPEAT DILATION OF INTRAVASCULAR STENTS IN CONGENITAL HEART-DEFECTS [J].
ING, FF ;
GRIFKA, RG ;
NIHILL, MR ;
MULLINS, CE .
CIRCULATION, 1995, 92 (04) :893-897
[4]  
ING FF, 2001, J AM COLL CARDIOL S, pA500
[5]   Early results and medium-term follow-up of stent implantation for mild residual or recurrent aortic coarctation [J].
Marshall, AC ;
Perry, SB ;
Keane, JF ;
Lock, JE .
AMERICAN HEART JOURNAL, 2000, 139 (06) :1054-1060
[6]   IMPLANTATION OF BALLOON-EXPANDABLE INTRAVASCULAR GRAFTS BY CATHETERIZATION IN PULMONARY-ARTERIES AND SYSTEMIC VEINS [J].
MULLINS, CE ;
OLAUGHLIN, MP ;
VICK, GW ;
MAYER, DC ;
MYERS, TJ ;
KEARNEY, DL ;
SCHATZ, RA ;
PALMAZ, JC .
CIRCULATION, 1988, 77 (01) :188-199
[7]   USE OF ENDOVASCULAR STENTS IN CONGENITAL HEART-DISEASE [J].
OLAUGHLIN, MP ;
PERRY, SB ;
LOCK, JE ;
MULLINS, CE .
CIRCULATION, 1991, 83 (06) :1923-1939
[8]   Endovascular stent implantation for the management of postoperative right ventricular outflow tract obstruction: Clinical efficacy [J].
Ovaert, C ;
Caldarone, CA ;
McCrindle, BW ;
Nykanen, D ;
Freedom, RM ;
Coles, JG ;
Williams, WG ;
Benson, LN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (05) :886-893
[9]   Endovascular stent implantation in the pulmonary arteries of infants and children without the use of a long vascular sheath [J].
Pass, RH ;
Hsu, DT ;
Garabedian, CP ;
Schiller, MS ;
Jayakumar, KA ;
Hellenbrand, WE .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (04) :505-509
[10]   Initial experience with IntraTherapeutics IntraStent DoubleStrut LD stents in patients with congenital heart defects [J].
Rutledge, JM ;
Mullins, CE ;
Nihill, MR ;
Grifka, RG ;
Vincent, JA .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) :541-548