Energy simulation and analysis of the heat recovery variable refrigerant flow system in winter

被引:41
作者
Li, Yue Ming [1 ]
Wu, Jing Yi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
关键词
HR-VRE system; Heat recovery; Energy simulation; EnergyPlus software; AIR-CONDITIONING SYSTEM; COOLING CONDITIONS; UNIT;
D O I
10.1016/j.enbuild.2010.01.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat recovery variable refrigerant flow (HR-VRF) system can supply cooling and heating for the building simultaneously and make good use of the indoor cooling and heating capacity efficiently. This system has a good energy performance and can meet the emerging requirements of modern buildings. In order to evaluate the energy features of the system, a new energy simulation module is developed and embedded in the dynamic energy simulation program, EnergyPlus. Using the program with the newly developed module, the dynamic energy simulation is performed for a simplified typical commercial building. The indoor thermal comfort of the building in winter and the setting temperature of the system are analyzed. Based on the simulation results, the energy characteristics of the system are investigated, and it is indicated that different methods of the temperature control and the percentage of the heat recovery have influence on the relative ratio of the energy saving. If the HR-VRF system adopts the same temperature control method as the heat pump VRF (HP-VRF) system, the HR-VRF system promises 15-17% energy-saving potential, when compared to the HP-VRF system. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1093 / 1099
页数:7
相关论文
共 17 条
[1]   Field performance measurements of a heat pump desiccant unit in dehumidification mode [J].
Aynur, T. N. ;
Hwang, Y. H. ;
Radermacher, R. .
ENERGY AND BUILDINGS, 2008, 40 (12) :2141-2147
[2]   Simulation comparison of VAV and VRF air conditioning systems in an existing building for the cooling season [J].
Aynur, Tolga N. ;
Hwang, Yunho ;
Radermacher, Reinhard .
ENERGY AND BUILDINGS, 2009, 41 (11) :1143-1150
[3]   EnergyPlus: creating a new-generation building energy simulation program [J].
Crawley, DB ;
Lawrie, LK ;
Winkelmann, FC ;
Buhl, WF ;
Huang, YJ ;
Pedersen, CO ;
Strand, RK ;
Liesen, RJ ;
Fisher, DE ;
Witte, MJ ;
Glazer, J .
ENERGY AND BUILDINGS, 2001, 33 (04) :319-331
[4]  
CRAWLEY DB, 2001, 7 INT IBPSA C RIO DE, P51
[5]  
*DAKIN IND LTD, 2008, VR8 DAKIN IND LTD
[6]   Indoor thermal comfort characteristics under the control of a direct expansion air conditioning unit having a variable-speed compressor and a supply air fan [J].
Deng Shiming ;
Li Zheng ;
Qu Minglu .
APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) :2187-2193
[7]  
*DOE, 2005, ENERGYPLUS DOC ENG R
[8]   Development and testing of a multi-type air conditioner without using AC inverters [J].
Hu, SC ;
Yang, RH .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (03) :373-383
[9]   Experimental validation of the simulation module of the water-cooled variable refrigerant flow system under cooling operation [J].
Li, Yue Ming ;
Wu, Jing Yi ;
Shiochi, Sumio .
APPLIED ENERGY, 2010, 87 (05) :1513-1521
[10]   Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions [J].
Li, Yueming ;
Wu, Jingyi ;
Shiochi, Sumio .
ENERGY AND BUILDINGS, 2009, 41 (09) :949-957