Image Reconstruction in Magnetic Resonance Conductivity Tensor Imaging (MRCTI)

被引:8
|
作者
Degirmenci, Evren [1 ]
Eyuboglu, B. Murat [1 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
关键词
Anisotropic conductivity; electrical impedance; imaging; magnetic resonance; reconstruction; tensor; tomography; ELECTRICAL-IMPEDANCE TOMOGRAPHY; CURRENT-DENSITY; MR-EIT; MREIT; ALGORITHM; SIMULATION;
D O I
10.1109/TMI.2011.2171192
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotropic conductivity reconstruction algorithms are proposed to reconstruct high resolution conductivity tensor images. Performances of these four algorithms and a previously proposed algorithm are evaluated in several aspects and compared.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 50 条
  • [31] Constrained Reconstruction for Sparse Magnetic Resonance Imaging
    Placidi, Giuseppe
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 89 - 92
  • [32] Comparison of Five Conductivity Tensor Models and Image Reconstruction Methods Using MRI
    Katoch, Nitish
    Choi, Bup-Kyung
    Park, Ji-Ae
    Ko, In-Ok
    Kim, Hyung-Joong
    MOLECULES, 2021, 26 (18):
  • [33] Sensitivity and resolution improvement for in vivo magnetic resonance current-density imaging of the human brain
    Goeksu, Cihan
    Scheffler, Klaus
    Gregersen, Frooi
    Eroglu, Hasan H.
    Heule, Rahel
    Siebner, Hartwig R.
    Hanson, Lars G.
    Thielscher, Axel
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3131 - 3146
  • [34] Fourier transform magnetic resonance current density imaging (FT-MRCDI) from one component of magnetic flux density
    Ider, Yusuf Ziya
    Birgul, Ozlem
    Oran, Omer Faruk
    Arikan, Orhan
    Hamamura, Mark J.
    Muftuler, L. Tugan
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11) : 3177 - 3199
  • [35] Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
    Mueller, Hans-Peter
    Kassubek, Jan
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (77):
  • [36] Magnetic Resonance Electrical Impedance Tomography (MREIT): conductivity and current density imaging
    Seo, JK
    Kwon, O
    Woo, EJ
    SECOND INTERNATIONAL CONFERENCE ON INVERSE PROBLEMS: RECENT THEORETICAL DEVELOPMENTS AND NUMERICAL APPROACHES, 2004, 2005, 12 : 140 - 155
  • [37] Multi-Contrast Magnetic Resonance Image Reconstruction
    Liu, Meng
    Chen, Yunmei
    Zhang, Hao
    Huang, Feng
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [38] Image Quality Assessment for Magnetic Resonance Imaging
    Kastryulin, Sergey
    Zakirov, Jamil
    Pezzotti, Nicola
    Dylov, Dmitry V.
    IEEE ACCESS, 2023, 11 : 14154 - 14168
  • [39] Denoising of Bz data for conductivity reconstruction in magnetic resonance electrical impedance tomography (MREIT)
    Jeon, Kiwan
    Lee, Chang-Ock
    MATHEMATICAL AND STATISTICAL METHODS FOR IMAGING, 2011, 548 : 85 - 100
  • [40] Reconstruction of biologic tissue conductivity from noisy magnetic field by integral equation method
    Liu, Jijun
    Xu, Huilin
    APPLIED MATHEMATICS AND COMPUTATION, 2011, 218 (06) : 2647 - 2660