An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation

被引:15
|
作者
Kim, Jung-Ha [1 ]
Hill, Robin [1 ,2 ]
Kuncic, Zdenka [1 ]
机构
[1] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
[2] Royal Prince Alfred Hosp, Dept Radiat Oncol, Camperdown, NSW 2050, Australia
关键词
ION-CHAMBER RESPONSE; ENERGY-DEPENDENCE; BREAST-CANCER; CALCULATION ALGORITHMS; ELECTRON-TRANSPORT; PHOTON; RADIOTHERAPY; SIMULATION; DOSIMETRY; FILM;
D O I
10.1088/0031-9155/57/14/N267
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo (MC) method has proven invaluable for radiation transport simulations to accurately determine radiation doses and is widely considered a reliable computational measure that can substitute a physical experiment where direct measurements are not possible or feasible. In the EGSnrc/BEAMnrc MC codes, there are several user-specified parameters and customized transport algorithms, which may affect the calculation results. In order to fully utilize the MC methods available in these codes, it is essential to understand all these options and to use them appropriately. In this study, the effects of the electron transport algorithms in EGSnrc/BEAMnrc, which are often a trade-off between calculation accuracy and efficiency, were investigated in the buildup region of a homogeneous water phantom and also in a heterogeneous phantom using the DOSRZnrc user code. The algorithms and parameters investigated include: boundary crossing algorithm (BCA), skin depth, electron step algorithm (ESA), global electron cutoff energy (ECUT) and electron production cutoff energy (AE). The variations in calculated buildup doses were found to be larger than 10% for different user-specified transport parameters. We found that using BCA = EXACT gave the best results in terms of accuracy and efficiency in calculating buildup doses using DOSRZnrc. In addition, using the ESA = PRESTA-I option was found to be the best way of reducing the total calculation time without losing accuracy in the results at high energies (few keV similar to MeV). We also found that although choosing a higher ECUT/AE value in the beam modelling can dramatically improve computation efficiency, there is a significant trade-off in surface dose uncertainty. Our study demonstrates that a careful choice of user-specified transport parameters is required when conducting similar MC calculations.
引用
收藏
页码:N267 / N278
页数:12
相关论文
共 50 条
  • [1] Monte Carlo modeling of the Elekta Versa HD and patient dose calculation with EGSnrc/BEAMnrc
    Paschal, Holly M.
    Kabat, Christopher N.
    Papaconstadopoulos, Pavlos
    Kirby, Neil A.
    Myers, Pamela A.
    Wagner, Timothy D.
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09):
  • [2] Validation of an electron Monte Carlo dose calculation algorithm in the presence of heterogeneities using EGSnrc and radiochromic film measurements
    Aubry, Jean-Francois
    Bouchard, Hugo
    Bessieres, Igor
    Lacroix, Frederic
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 2 - 14
  • [3] Comprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm
    Zhang, Aizhen
    Wen, Ning
    Nurushev, Teamour
    Burmeister, Jay
    Chetty, Indrin J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 127 - 145
  • [4] Evaluation of the RayStation electron Monte Carlo dose calculation algorithm
    Richmond, Neil
    Allen, Vincent
    Wyatt, Jonathan
    Codling, Richard
    MEDICAL DOSIMETRY, 2020, 45 (02) : 159 - 167
  • [5] Monte Carlo evaluation of the effect of inhomogeneities on dose calculation for low energy photons intra-operative radiation therapy in pelvic area
    Chiavassa, Sophie
    Buge, Francois
    Herve, Chloe
    Delpon, Gregory
    Rigaud, Jerome
    Lisbona, Albert
    Supiot, Sthephane
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 956 - 962
  • [6] Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams
    Vandervoort, Eric J.
    Tchistiakova, Ekaterina
    La Russa, Daniel J.
    Cygler, Joanna E.
    MEDICAL PHYSICS, 2014, 41 (02) : 021711
  • [7] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15
  • [8] Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4
    Ahmad, Syed Bilal
    Sarfehnia, Arman
    Paudel, Moti Raj
    Kim, Anthony
    Hissoiny, Sami
    Sahgal, Arjun
    Keller, Brian
    MEDICAL PHYSICS, 2016, 43 (02) : 894 - 907
  • [9] Neutron track length estimator for GATE Monte Carlo dose calculation in radiotherapy
    Elazhar, H.
    Deschler, T.
    Letang, J. M.
    Nourreddine, A.
    Arbor, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12)
  • [10] Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system
    Paudel, Moti R.
    Kim, Anthony
    Sarfehnia, Arman
    Ahmad, Sayed B.
    Beachey, David J.
    Sahgal, Arjun
    Keller, Brian M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 230 - 241