Visual CRT sharpness estimation using a fiducial marker set

被引:1
作者
Kohm, KS [1 ]
Cameron, AW [1 ]
Van Metter, RL [1 ]
机构
[1] Eastman Kodak Co, Rochester, NY 14650 USA
来源
MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES | 2001年 / 4319卷
关键词
CRT; sharpness estimation; quality assurance; monitor quality; softcopy display;
D O I
10.1117/12.428067
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A visual estimation technique has been developed to quickly, yet quantitatively, determine the sharpness quality of CRT displays. While high-resolution camera measurement equipment accurately characterizes display sharpness, the equipment cost is high and the measurements are time consuming to perform. Previously reported visual sharpness assessment techniques are either qualitative or the quantitative measures do not possess adequate sensitivity. The rating scheme investigated in this study provides a practical solution for tracking monitor sharpness in a clinical environment. The target consists of a high frequency, high contrast pattern with an embedded, magnified fiducial marker set based upon a Gaussian model for the CRT spot. The magnification of the marker set allows the reference to remain nearly invariant to the actual sharpness of the display. In this study, three commercially available diagnostic displays were evaluated, each at two luminance levels and seven static focus settings. High-resolution CCD camera measurements were acquired for each display and setting combination. The visual sharpness estimate target was then displayed and scored by observers. High correlation was found between the visual ratings and the photometric measurements. More importantly, the sensitivity of the target produced observer ratings, which distinguish between the measured CRT spot sizes at different focus levels.
引用
收藏
页码:286 / 297
页数:12
相关论文
共 14 条
[1]  
*BARC DISPL SYST, MED MON CONF CONS SO
[2]  
BRIGGS SJ, 1993, SID, V93, P396
[3]  
BRIGGS SJ, 1979, MANUAL DIGITAL TEST
[4]   Factors affecting CRT display performance: specifying what works [J].
Compton, KD .
MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 :412-423
[5]  
*DAT RAY CORP, DR KAL MON CAL SOFTW
[6]  
*DOM IM SYST INC, CAL TQA
[7]   Quantitative evaluation of overall electronic display quality [J].
Hangiandreou, NJ ;
Fetterly, KA ;
Bernatz, SN ;
Cesar, LJ ;
Groth, DS ;
Felmlee, JP .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) :180-186
[8]  
IKI T, 1997, SID SEMINAR LECT NOT
[9]  
KELLER P, 1989, SID, V89, P204
[10]  
Kruger RL, 2000, RADIOLOGY, V217, P521