Dynamic contour tonometry in comparison to intracameral IOP measurements

被引:85
作者
Boehm, Andreas G. [1 ]
Weber, Anja [1 ]
Pillunat, Lutz E. [1 ]
Koch, Rainer [2 ]
Spoerl, Eberhard [1 ]
机构
[1] Univ Dresden, Dept Ophthalmol, D-01307 Dresden, Germany
[2] Univ Dresden, Inst Med Stat & Biometry, D-01307 Dresden, Germany
关键词
D O I
10.1167/iovs.07-1366
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of the study was to examine the effect of central corneal thickness (CCT), corneal curvature, astigmatism, axial length (AL), and age on measurements with the Pascal Dynamic Contour Tonometer (DCT). METHODS. In a prospective clinical trial 75 eyes of 75 patients undergoing phacoemulsification were examined. Before phacoemulsification, the anterior chamber was cannulated at the temporal corneal limbus. In a closed system the IOP was directly set to 15, 20, or 35 mm Hg with a manometric water column. IOP measurements taken by DCT were compared to intracameral measurements with a precision reference pressure sensor. RESULTS. Measurements from 60 patients were suitable for statistical analysis. At IOP of 15 mm Hg, the mean difference between IOP measured by DCT and intracameral IOP was -0.02 +/- 1.32 mm Hg; at 20 mm Hg it was -0.2 +/- 1.44 mm Hg and at 35 mm Hg, -0.84 +/- 1.90 mm Hg. The concordance coefficient according to Lin was 0.9763, showing good agreement between DCT- and intracamerally measured IOP. There was a statistically significant correlation between the difference in IOP measured by DCT minus intracameral IOP and CCT (P = 0.0291, R-2 = 0.00012). All other parameters had no statistically significant effect on the difference between DCT and intracameral IOP (corneal curvature, P = 0.6094, R-2 = 0.00367; age, P = 0.9198, R-2 = 0.000003; astigmatism, P = 0.1564, R-2 = 0.08497; and axial length, P = 0.9484, R-2 = 0.00008). CONCLUSIONS. Measurements with the DCT showed good concordance with intracameral IOP. CCT exerted a statistically significant but clinically irrelevant effect on measurements with the DCT.
引用
收藏
页码:2472 / 2477
页数:6
相关论文
共 27 条
[1]   Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) [J].
Brandt, JD ;
Beiser, JA ;
Kass, MA ;
Gordon, MO .
OPHTHALMOLOGY, 2001, 108 (10) :1779-1788
[2]  
EHLERS N, 1974, ACTA OPHTHALMOL, V52, P740
[3]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[4]   Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonomet [J].
Francis, Brian A. ;
Hsieh, Amy ;
Lai, Mei-Ying ;
Chopra, Vikas ;
Pena, Fernando ;
Azen, Stanley ;
Varma, Rohit .
OPHTHALMOLOGY, 2007, 114 (01) :20-26
[5]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[6]  
HANSEN FK, 1971, ACTA OPHTHALMOL, V49, P775
[7]   Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility [J].
Herdener, Sonja ;
Pache, Mona ;
Lautebach, Sonja ;
Funk, Jens .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (07) :1027-1030
[8]   Measuring intraocular pressure-adjustments for corneal thickness and new technologies [J].
Herndon, Leon W. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) :115-119
[9]   Goldmann applanation tonometry and dynamic contour tonometry.: Comparison of intraocular pressure measurements in the course of product certification according to EN ISO 8612:2001 [J].
Hoffmann, E. ;
Pfeiffer, N. ;
Barleon, L. ;
Grus, F. .
OPHTHALMOLOGE, 2006, 103 (04) :317-320
[10]  
JOHNSON M, 1978, ARCH OPHTHALMOL-CHIC, V96, P664