Evaluation of miniature data loggers for body temperature measurement during sporting activities

被引:17
作者
Fuller, A
Oosthuyse, T
Maloney, SK
Mitchell, D
机构
[1] Univ Witwatersrand, Sch Med, Dept Physiol, ZA-2193 Johannesburg, South Africa
[2] Univ New S Wales, Sch Biol Sci, Sydney, NSW 2052, Australia
关键词
telemetry; exercise; thermometers;
D O I
10.1007/s004210050518
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We recorded body temperatures in four runners, two squash players and one swimmer at 1-min intervals using miniature data loggers. These single-channel loggers are small and light (25 g), and were easily carried by the athletes during their sporting activities. Wide-range loggers (-37 degrees C to +46C), which had a temperature resolution of 0.4 degrees C, were used to measure thigh skin temperature. Auditory canal temperature and rectal temperature were measured with narrow-range loggers (+ 34 degrees C to + 46 degrees C) which had a considerably higher resolution (0.04 degrees C). With the aid of visual analogue scales subjects reported that the thermometric equipment caused very little discomfort or impairment of exercise performance. Loggers connected to uncoated bead thermistors (used for skin and auditory canal temperatures) had a thermal time constant of 0.4 s, and that of the coated thermistors (rectal probes) was 6 s. We were able to waterproof the equipment and measure rectal temperature in a swimmer. Hot (35 degrees C) or cold (5 degrees C) ambient temperatures had an insignificant effect on the intrinsic accuracy of the data loggers, even when used without recalibration at those temperatures. We believe that miniature temperature loggers are convenient and accurate thermometers for use during sporting activities and may provide new insights into thermoregulation during exercise.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 12 条
[1]   THERMOREGULATION DURING MARATHON RUNNING IN COOL, MODERATE, AND HOT ENVIRONMENTS [J].
ADAMS, WC ;
FOX, RH ;
FRY, AJ ;
MACDONALD, IC .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (06) :1030-1037
[2]  
Brengelmann G.L., 1987, MAN STRESSFUL ENV, P5
[3]   Monitoring rectal core temperature in marathon swimmers [J].
Finlay, JB ;
Lysynski, B ;
Liggins, AB ;
Weir, RC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (01) :97-100
[4]  
KEATINGE WR, 1990, J PHYSIOL-LONDON, V430, pP93
[5]  
KEATINGE WR, 1989, J PHYSIOL-LONDON, V412, pP42
[6]   VALIDATION OF A TEMPERATURE TELEMETRY SYSTEM DURING MODERATE AND STRENUOUS EXERCISE [J].
KOLKA, MA ;
QUIGLEY, MD ;
BLANCHARD, LA ;
TOYOTA, DA ;
STEPHENSON, LA .
JOURNAL OF THERMAL BIOLOGY, 1993, 18 (04) :203-210
[7]   ORAL-TEMPERATURE AS AN INDEX OF CORE TEMPERATURE DURING HEAT TRANSIENTS [J].
MAIRIAUX, P ;
SAGOT, JC ;
CANDAS, V .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1983, 50 (03) :331-341
[8]  
Mitchell D, 1985, Physiologist, V28, P507
[9]   Activity, blood temperature and brain temperature of free-ranging springbok [J].
Mitchell, D ;
Maloney, SK ;
Laburn, HP ;
Knight, MH ;
Kuhnen, G ;
Jessen, C .
JOURNAL OF COMPARATIVE PHYSIOLOGY B-BIOCHEMICAL SYSTEMS AND ENVIRONMENTAL PHYSIOLOGY, 1997, 167 (05) :335-343
[10]   Effects of hyperhydration on total body water, temperature regulation and performance of elite young soccer players in a warm climate [J].
RicoSanz, J ;
Frontera, WR ;
Rivera, MA ;
RiveraBrown, A ;
Mole, PA ;
Meredith, CN .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1996, 17 (02) :85-91