Results from a beam test of a prototype PLT diamond pixel telescope

被引:6
作者
Hall-Wilton, R. [2 ]
Loos, R. [2 ]
Ryjov, V. [2 ]
Pernicka, M. [3 ]
Schmied, S. [3 ]
Steninger, H. [3 ]
Halyo, V. [4 ]
Harrop, B. [4 ]
Hunt, A. [4 ]
Marlow, D. [4 ]
Sands, B. [4 ]
Stickland, D. [4 ]
Atramentov, O. [1 ]
Bartz, E. [1 ]
Doroshenko, J. [1 ]
Gershtein, Y. [1 ]
Hits, D. [1 ]
Schnetzer, S. [1 ]
Stone, R. [1 ]
Butler, P. [5 ]
Lansley, S. [5 ]
Rodrigues, N. [5 ]
Bugg, W. [6 ]
Hollingsworth, M. [6 ]
Spanier, S. [6 ]
Johns, W. [7 ]
机构
[1] Rutgers State Univ, Piscataway, NJ 08855 USA
[2] CERN, Geneva, Switzerland
[3] Inst High Energy Phys, Vienna, Austria
[4] Princeton Univ, Princeton, NJ 08544 USA
[5] Univ Canterbury, Christchurch 1, New Zealand
[6] Univ Tennessee, Knoxville, TN USA
[7] Vanderbilt Univ, Nashville, TN USA
基金
美国国家科学基金会;
关键词
Pixel detectors; Radiation hardness; Diamond sensors; Luminosity measurement; CMS; LHC; DETECTOR;
D O I
10.1016/j.nima.2010.04.097
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe results from a beam test of a telescope consisting of three planes of single-crystal, diamond pixel detectors. This telescope is a prototype for a small-angle luminosity monitor, the Pixel Luminosity Telescope (PLT), for CMS. We recorded the pixel addresses and pulse heights of all pixels over threshold as well as the fast-or signals from all three telescope planes. We present results on the telescope performance including occupancies, pulse heights, fast-or efficiencies and particle tracking. These results show that the PLT design meets all required specifications. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S130 / S136
页数:7
相关论文
共 4 条
[1]   Radiation hard diamond sensors for future tracking applications [J].
Adam, W. ;
de Boer, W. ;
Borchi, E. ;
Bruzzi, M. ;
Colledani, C. ;
D'Angelo, P. ;
Dabrowski, V. ;
Dulinski, W. ;
van Eijk, B. ;
Eremin, V. ;
Fizzotti, F. ;
Frais-Koelbl, H. ;
Furetta, C. ;
Gan, K. K. ;
Gorisek, A. ;
Griesmayer, E. ;
Grigoriev, E. ;
Hartjes, F. ;
Hrubec, J. ;
Huegging, F. ;
Kagan, H. ;
Kaplon, J. ;
Kass, R. ;
Knoepfle, K. T. ;
Krammer, M. ;
Lange, W. ;
Logiudice, A. ;
Manfredotti, C. ;
Mathes, M. ;
Menichelli, D. ;
Mishina, M. ;
Moroni, L. ;
Noomen, J. ;
Oh, A. ;
Pernegger, H. ;
Pernicka, M. ;
Potenza, R. ;
Riester, J. L. ;
Rudge, A. ;
Sala, S. ;
Schnetzer, S. ;
Sciortino, S. ;
Stone, R. ;
Sutera, C. ;
Trischuk, W. ;
Velthuis, J. J. ;
Vincenzo, B. ;
Weilhammer, P. ;
Weingarten, J. ;
Wermes, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01) :278-283
[2]   Design and performance of the CMS pixel detector readout chip [J].
Kaestli, H. Chr. ;
Barbero, M. ;
Erdmann, W. ;
Hoermann, Ch. ;
Horisberger, R. ;
Kotlinski, D. ;
Meier, B. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01) :188-194
[3]   The control and readout systems of the CMS pixel barrel detector [J].
Kotlinski, D. ;
Bartz, E. ;
Erdmann, W. ;
Gabathuler, K. ;
Horisberger, R. ;
Hoermann, Ch. ;
Kaestli, H.-Ch. ;
Meier, B. ;
Schnetzer, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (01) :73-78
[4]  
ROHE T, 2010, 11 EUR S SEM DET