Viscoelastic property measurement in thin tissue constructs using ultrasound

被引:38
|
作者
Liu, Dalong [2 ]
Ebbini, Emad S. [1 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/TUFFC.2008.655
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present a dual-element concave ultrasound transducer system for generating and tracking of localized tissue displacements in thin tissue constructs on rigid substrates. The system is comprised of a highly focused PZT-4 5-MHz acoustic radiation force (ARF) transducer and a confocal 25-MHz polyvinylidene fluoride imaging transducer. This allows for the generation of measurable displacements in tissue samples on rigid substrates with thickness values down to 500 mu m. Impulse-like and longer duration sine-modulated ARF pulses are possible with intermittent M-mode data acquisition for displacement tracking. The operations of the ARF and imaging transducers are strictly synchronized using an integrated system for arbitrary waveform generation and data capture with a shared timebase. This allows for virtually jitter-free pulse-echo data well suited for correlation-based speckle tracking. With this technique we could faithfully capture the entire dynamics of the tissue axial deformation at pulse-repetition frequency values up to 10 kHz. Spatio-temporal maps of tissue displacements in response to a variety of modulated ARF beams were produced in tissue-mimicking elastography phantoms on rigid substrates. The frequency response was measured for phantoms with different modulus and thickness values. The frequency response exhibited resonant behavior with the resonance frequency being inversely proportional to the sample thickness. This resonant behavior can be used in obtaining high-contrast imaging using magnitude and phase response to sinusoidally modulated ARF beams. Furthermore, a second order forced harmonic oscillator (FHO) model was shown to capture this resonant behavior. Based on the FHO model, we used the extended Kalman filter (EKF) for tracking the apparent modulus and viscosity of samples subjected to do and sinusoidally modulated ARF. The results show that the stiffness (apparent modulus) term in the FHO is largely time-invariant and can be estimated robustly using the EKF. On the other hand, the damping (apparent viscosity) is time varying. These findings were confirmed by comparing the magnitude response of the FHO (with parameters obtained using the EKF) with the measured ones for different thin tissue constructs.
引用
收藏
页码:368 / 383
页数:16
相关论文
共 50 条
  • [41] Measurement of Subcutaneous Adipose Tissue in Pre-School Children using Ultrasound
    Kelso, Anne
    Vogel, Katharina
    Steinacker, Juergen
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 486 - 486
  • [42] Ultrasound tissue-mimicking materials using oil gel and measurement of their characteristics
    Kondo, T
    Fujimoto, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2002, 41 (5B): : 3598 - 3599
  • [43] Effect of estrogen deficiency on regional variation of a viscoelastic tissue property of bone
    Kim, Do-Gyoon
    Huja, Sarandeep S.
    Navalgund, Anand
    D'Atri, Andrew
    Tee, BoonChing
    Reeder, Sarah
    Lee, Hye Ri
    JOURNAL OF BIOMECHANICS, 2013, 46 (01) : 110 - 115
  • [44] Viscoelastic measurement of tissue-like phantom using a pulsed wave Doppler ultrasonic system
    Hou, CJ
    Chung, KC
    IEEE EMBS APBME 2003, 2003, : 270 - 271
  • [45] Development of a High-Throughput Ultrasound Technique for the Analysis of Tissue Engineering Constructs
    Stukel, Jessica M.
    Goss, Monika
    Zhou, Haoyan
    Zhou, Wenda
    Willits, Rebecca Kuntz
    Exner, Agata A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (03) : 793 - 802
  • [46] Development of a High-Throughput Ultrasound Technique for the Analysis of Tissue Engineering Constructs
    Jessica M. Stukel
    Monika Goss
    Haoyan Zhou
    Wenda Zhou
    Rebecca Kuntz Willits
    Agata A. Exner
    Annals of Biomedical Engineering, 2016, 44 : 793 - 802
  • [47] ON THE VISCOELASTIC PROPERTY MEASUREMENT OF FILLED POLYMERS BY DYNAMIC MECHANICAL ANALYZER (DMA)
    Phansalkar, Sukrut Prashant
    Han, Bongtae
    Akbari, Ehsan
    Vaitiekunas, Paulius
    PROCEEDINGS OF ASME 2022 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2022, 2022,
  • [48] Measurement of Viscoelastic Properties of In Vivo Swine Myocardium Using Lamb Wave Dispersion Ultrasound Vibrometry (LDUV)
    Urban, Matthew W.
    Pislaru, Cristina
    Nenadic, Ivan Z.
    Kinnick, Randall R.
    Greenleaf, James F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 247 - 261
  • [49] Tissue engineering of osteochondral constructs in vitro using bioreactors
    Haasper, Carl
    Zeichen, Johannes
    Meister, Roland
    Krettek, Christian
    Jagodzinski, Michael
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 : S66 - S76
  • [50] Nasal Reconstruction Using Tissue Engineered Constructs An Update
    Oseni, Adelola O.
    Butler, Peter E.
    Seifalian, Alexander M.
    ANNALS OF PLASTIC SURGERY, 2013, 71 (02) : 238 - 244